Power range: 0.75~250 kW
Voltage: 380~480 V
Control: scalar V/f, vector
Model | Power (kW) | Current (A) | Frame size
ACS580-01-03A3 | 1.1 | 3.3 | R0
ACS580-01-04A1 | 1.5 | 4.1 | R0
ACS580-01-05A6 | 2.2 | 5.6 | R0
ACS580-01-07A6 | 3.0 | 7.6 | R1
ACS580-01-09A6 | 4.0 | 9.6 | R1
ACS580-01-12A6 | 5.5 | 12.6 | R2
ACS580-01-16A6 | 7.5 | 16.6 | R2
ACS580-01-24A6 | 11 | 24.2 | R3
ACS580-01-30A6 | 15 | 30.1 | R3
ACS580-01-38A3 | 18.5 | 38.3 | R4
ACS580-01-45A6 | 22 | 45.6 | R4
ACS580-01-61A3 | 30 | 61.3 | R5
ACS580-01-72A6 | 37 | 72.6 | R5
ACS580-01-96A6 | 45 | 96.6 | R6
ACS580-01-124A6 | 55 | 124 | R6
ACS580-01-156A6 | 75 | 156 | R7
ACS580-01-180A6 | 90 | 180 | R7
ACS580-01-240A6 | 110 | 240 | R8
ACS580-01-312A6 | 132 | 312 | R8
1. V/f control (scalar)
Simple, multi-motor drive
2. Vector control (sensorless)
High-precision torque / speed control
Speed ratio 1:100
3. Vector control (with encoder)
Speed ratio 1:1000
Position control
4. Built-in PLC (optional)
5. Energy recovery (braking resistor / 4-quadrant)
6. EMC filter built-in
7. Safety function (STO)
8. App remote monitoring
Overcurrent / overvoltage / undervoltage / overload / overheating
Motor phase loss / ground fault
Communication fault
1. Match motor power
VFD power >= motor power
For heavy loads select one rating higher
2. Match current (more accurate)
VFD rated current >= motor rated current
3. Overload capacity
150% for 1 minute (heavy duty)
110% continuous
4. Ambient temperature
Standard environment 40 C
Derated at high temperature
5. Altitude
>1000 m derating
1% reduction per 100 m rise
6. Switching frequency
Default 4 kHz
For low-noise requirement: 8~16 kHz (derated)
Motor: 15 kW, 400 V, 30 A, 4-pole
1. Select ACS580-01-30A6 (15 kW, 30.1 A)
2. Overload: 150% x 30.1 = 45 A, 1 minute
3. Motor starting current typically 6x rated = 180 A
VFD soft-start limits current
4. At altitude 1500 m:
Derating: (1500-1000)/100 x 1% = 5%
Actual capacity: 15 x 0.95 = 14.25 kW -> insufficient
Select higher rating: ACS580-01-38A3 (18.5 kW)
1. Heat dissipation space (>=100 mm above and below)
2. Input reactor (recommended for >22 kW)
3. Output reactor (for long cable >50 m)
4. Braking resistor (frequent braking)
5. EMC filter (precision applications)
6. Reliable grounding
7. Shielded control wiring
Modular structure:
- Control Unit (CU)
- Power Module (PM)
- Sensor Module (SM)
Power: 0.55~250 kW
Voltage: 380~480 V
1. CU230P-2: simple applications (V/f)
2. CU240B-2: mid-range (V/f + vector)
3. CU240E-2: high-end (vector + functions)
4. CU250S-2: servo (with encoder)
1. PM240-2 (standard)
V/f, sensorless vector
External braking resistor
2. PM250 (energy recovery)
Braking energy fed back to grid
Energy Saving
3. PM260 (multi-drive)
Shared DC bus
Model | Power (kW) | Output current (A) | Overload current (A, 60 s)
6SL3210-1KE11-8UF1| 0.55 | 1.9 | 2.85
6SL3210-1KE12-3UF1| 0.75 | 2.4 | 3.6
6SL3210-1KE14-1UF1| 1.1 | 3.2 | 4.8
6SL3210-1KE16-1UF1| 1.5 | 4.0 | 6.0
6SL3210-1KE17-5UF1| 2.2 | 5.9 | 8.85
6SL3210-1KE21-0UF1| 3.0 | 7.7 | 11.55
6SL3210-1KE21-3UF1| 4.0 | 9.3 | 13.95
6SL3210-1KE21-8UF1| 5.5 | 13.0 | 19.5
6SL3210-1KE22-6UF1| 7.5 | 18.0 | 27.0
6SL3210-1KE23-8UF1| 11 | 27.5 | 41.25
6SL3210-1KE24-6UF1| 15 | 33.5 | 50.25
6SL3210-1KE27-5UF1| 18.5 | 41.0 | 61.5
6SL3210-1KE31-0UF1| 22 | 49.0 | 73.5
6SL3210-1KE31-8UF1| 30 | 63.0 | 94.5
6SL3210-1KE32-6UF1| 37 | 75.0 | 112.5
6SL3210-1KE33-7UF1| 45 | 88.0 | 132.0
6SL3210-1KE35-0UF1| 55 | 115 | 172.5
6SL3210-1KE38-4UF1| 75 | 155 | 232.5
6SL3210-1KE41-0UF1| 90 | 185 | 277.5
1. V/f control (linear / parabolic / multi-point)
2. Sensorless vector control (SLVC)
Speed ratio 1:200
Torque accuracy +/-5%
3. Vector control with encoder (VC)
Speed ratio 1:1000
Torque accuracy +/-2%
4. Function block programming (BICO)
5. Safety (STO / SS1 / SLS)
6. PROFIBUS / PROFINET communication
7. TIA Portal integration
1. BOP-2 panel (basic)
2. IOP panel (intelligent)
3. Starter software (PC)
4. TIA Portal(PC)
5. Commissioning wizard (quick)
1. Determine motor power and current
2. Select control unit (function requirement)
3. Select power module (power / current)
4. Select accessories:
- Input reactor
- Output reactor
- Braking resistor
- Filter
- Encoder interface
5. Select operator panel
ABB ACS580:
- Integrated design (simple)
- High integration
- Fast commissioning
- Slightly lower price
Siemens G120:
- Modular (flexible)
- TIA integration (automation)
- More safety functions
- PROFIdrive standard
Standalone application: ABB (simple)
PLC integration: Siemens (PROFINET)
Large automation: Siemens
General purpose: either
1. Motor parameters (must be entered correctly)
- Motor rated power P_N
- Motor rated voltage U_N
- Motor rated current I_N
- Motor rated frequency f_N (50 Hz)
- Motor rated speed n_N (1450 rpm)
- Power factor cos phi
- Motor pole count (4-pole)
2. Control mode
- V/f control (simple applications)
U/f curve selection
Voltage boost (low-frequency compensation)
- Vector control (high performance)
Motor parameter identification (automatic)
Speed ratio 1:200~1:1000
Torque control
- Vector with encoder (highest performance)
Encoder configuration
Speed ratio 1:1000+
Position control
3. Frequency setting
- Keypad (panel)
- Analog (0-10 V / 4-20 mA)
- Digital (multi-speed)
- Communication (Modbus / PROFINET)
4. Run command
- Keypad start / stop
- Terminals (digital input)
- Communication
1. Linear V/f (default)
Constant U/f
Suitable for constant-torque loads
(conveyor / hoist)
2. Parabolic V/f
Lower voltage at low frequency
Suitable for fans / pumps (square-law torque)
Energy Saving
3. Multi-point V/f
Custom
Special loads
4. Voltage boost
Increase voltage at low frequency
Compensate stator resistance drop
Improve starting torque
Too high causes overcurrent
Vector control requires motor parameter identification:
1. Stationary identification (motor stationary)
- Stator resistance
- Leakage inductance
2. Rotating identification (motor free-running)
- Rotor resistance
- Mutual inductance
- Encoder direction
3. Identification procedure (ABB):
- Enter motor nameplate parameters
- Motor disconnected from load
- Start ID Run (automatic)
- Wait for completion (a few minutes)
1. Acceleration time
Time from 0 to rated frequency
Too short: overcurrent
Too long: slow response
Experience: 5~30 seconds
2. Deceleration time
Too short: overvoltage (energy feedback)
Too long: slow response
Large load inertia: increase time
3. S-curve
Gradual ramp at start/end (reduce shock)
Suitable for conveyor / elevator
4. Multi-segment accel/decel
Different times for different conditions
1. Overcurrent protection
Current limit (150% rated)
Trip threshold (200%)
2. Overvoltage protection
Decel overvoltage: extend decel / braking resistor
Trip threshold (800 V DC)
3. Overload protection
Thermal model (I^2 t)
Trip curve (class 10 / class 20)
4. Undervoltage protection
Trip threshold (380 V x 85%)
5. Motor overheating
PTC / PT100 sensor
1. Mechanical check
- Motor disconnected (first time)
- Wiring correct
- Encoder (vector)
2. Parameter input
- Motor nameplate
- Control mode
- Frequency / command source
- Accel/decel
- Protection
3. Motor identification (vector)
4. No-load trial run
- Low-speed jog
- Check rotation direction
- Check vibration / noise
- Ramp up to rated speed
5. Loaded trial run
- Low-speed under load
- Monitor current
- Accelerate / decelerate
- Run at each speed
6. Performance optimization
- Speed-loop PI
- Torque loop
- Vibration suppression
7. Long-term operation
- Temperature monitoring
- Data logging
- Periodic inspection
1. Overcurrent at start
- Acceleration time too short
- Voltage boost too high
- Load jammed
2. Overvoltage at decel
- Deceleration time too short
- Add braking resistor
- Large load inertia
3. Motor overheating
- Harmonic losses
- Poor low-frequency cooling
- Use inverter-duty motor
4. Noise
- Low carrier frequency
- Raise to 8~16 kHz
5. Leakage current
- EMC filter
- Grounding
- Common-mode filter
1. MD200 (economy, 0.4~2.2 kW)
2. MD290 (general-purpose, 0.75~630 kW)
3. MD500 (high-performance, 0.75~710 kW)
4. MD810 (servo VFD, 0.75~75 kW)
Power range: 0.75~710 kW
Control: V/f, sensorless vector, vector with encoder
Speed ratio: 1:200 (sensorless) / 1:1000 (with encoder)
Overload: 150% 60 s, 180% 3 s
Built-in: PLC function, PID
Communication: Modbus / PROFINET / EtherCAT
(1) Domestic, high cost-performance
(2) Commissioning software Inovance
(3) Performance close to ABB / Siemens
(4) Good after-sales service
(5) Suitable for Chinese operating conditions
1. Select by motor power
2. Current matching
3. Duty factor
4. Accessories (reactor / braking resistor)
Inovance: cost-performance, service
ABB: brand, stability
Siemens: integration, ecosystem
General purpose: either
Critical applications: import
Other quick references in this series:Servo MotorGearboxCylinderPneumatic ComponentsHydraulic ComponentsSensorPLCTouchscreenElectrical ComponentsCouplingBearingValveMotor