A single missing tablet on a blister pack is a batch quality event, and manual sampling cannot catch it reliably. A backlight imaging scheme with area cameras makes empty pockets glow and tablets go dark, so the decision is both simple and auditable.
The mainstream approach photographs the whole card on a backlight: tablets block light and appear dark, empty pockets transmit and appear bright, so a grey threshold separates them cleanly. Resolution: pocket pitch runs 10 to 15 mm and 20 by 20 pixels per pocket is enough, so a 10 by 5 card with a 150 by 80 mm field fits comfortably inside a 5 MP camera. Reflection is the design trap: the aluminium foil is strongly specular, so diffuse the backlight and expose so the foil reads as an even grey while pockets go dark, keeping boundaries crisp. Lines running 20 to 40 m/min either stop per card or strobe and shoot on the fly.
Two algorithms cover the task. Template differencing against a golden image catches missing tablets, fragments and foreign objects at once. Regional counting assigns each pocket its own verdict window and checks the dark area, flagging any pocket below the area threshold. In practice combine them: whole card template screen first, fine judgement on suspects. Targets: zero escapes, since one missed tablet is a quality incident, and false rejects under 0.5 percent so the rejection mechanism does not stop the line constantly. Leave threshold margin for batch to batch colour variation, and use colour cameras or per channel judgement when pale and dark tablets share a line.
GMP ties the system to records and rejection. Store an image or verdict per card, traceable to batch and time, retained through shelf life plus a year as a rule. Couple detection to a rejection cylinder at the card separation station with action feedback into the PLC, because a stuck cylinder quietly passes rejects downstream. Validate in three steps, installation, operation and performance qualification, and challenge the system with seeded defective cards until three consecutive batches achieve 100 percent detection. Verify daily with a standard defect card, since light decay and lens fouling erode sensitivity.
| Element | Recommended setup | Key point |
|---|---|---|
| Imaging | Backlight plus area camera, whole card | Diffuse backlight tames foil glare |
| Resolution | 20×20 pixels per pocket | 5 MP camera gives margin |
| Algorithm | Whole card template plus pocket check | Zero escapes, under 0.5% rejects |
| Rejection link | Cylinder with action feedback to PLC | Alarm and stop on reject failure |
| Records | Image per card, batch traceable | Keep shelf life plus one year |
| Qualification | Seeded defect challenge test | Three batches at 100% detection |
Use this table when designing blister inspection and preparing GMP qualification. Prove imaging on samples before freezing camera and light, then set algorithms and thresholds, then wire rejection and records. The seeded defect challenge is non negotiable, and daily standard card checks guard against sensitivity decay.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Pharmaceutical GMP and equipment qualification practice; electrical safety per GB/T 5226.1 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.