Linear scale reading-head signal output and wiring

Reading heads speak two dialects - TTL square wave and 1Vpp sine - and mixing them up or abusing the shield wrecks the position loop. Learn the signatures, the wiring rules and the distance limits.

1. How it works

TTL mode emits RS-422 differential pairs A+ A-, B+ B-, Z+ Z- at about 3.5V swing, counted directly after interpolation in the controller; typical 20µm grating periods yield 1µm or 0.5µm resolution, wiring is simple, but runs beyond 10~25m degrade. The 1Vpp mode delivers 1-volt peak-to-peak sine pairs at 90 degrees, interpolated at high rate by the drive or an external box, reaching 0.1µm resolution and 50m of cable - the standard on high-end servos and measuring machines. Identify by nameplate and cable core count: six-core differential usually TTL, four-core analogue usually 1Vpp.

2. Practice and pitfalls

Wiring rules: shielded twisted pair with the shield 360-degree bonded to the head shell at one end and earthed at the drive end only; differential pairs kept together, never pairing A+ with B- in one twisted pair; unused cores insulated, not trimmed. Separate from power runs by 200mm, servo feedback cables included. De-energise before mating the fine-pin circular connectors of 1Vpp heads. Verify with the scope: TTL differential swing 3~3.5V, 1Vpp at 1V plus or minus 10 percent - a 30 percent amplitude drop points at connectors or cable. Beyond limits the symptoms are classic: fine at low speed, lost counts at speed, flaky homing; beyond 25m on TTL add a repeater box. The acceptance criterion is a circular Lissajous figure on X-Y mode - an ellipse means amplitude imbalance or phase error, check connectors first.

3. Linear scale signal standards comparison

StandardWaveform and levelUse and limits
TTL square differentialRS-422, about 3.5V swingSimple wiring, within 25m
1Vpp sine1V peak-peak, 90 degrees apartHigh-resolution interpolation, within 50m
InterpolationIn-controller for TTL, box for 1VppResolution 1µm down to 0.1µm
Shield earthingBonded at head, earthed at drive endBoth ends earthed invites loops
Duct separation200mm from servo power linesShared duct couples lost counts
Signal acceptanceCircular Lissajous, level within ±10%Ellipse means connector or cable fault

4. Notes

Two acceptance criteria sum up wiring quality: a circular Lissajous figure and on-spec amplitude. Archive the first commissioning screenshots and compare yearly - waveform decay shows up months before alarms, and replacing cable early beats a breakdown stop.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Digital interfaces and control circuits per GB/T 5226.1 (IEC 60204-1); differential transmission per the IEC 61158 series. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Running TTL cable 30m without a repeater:Edges soften and high-speed counts vanish in intermittent fashion - add a repeater box beyond 25m
② Earthing the shield at both ends:Ground loops couple into the pairs and position drifts with machine starts - single-point earth only
③ Twisting A+ with B- in one pair:Crosstalk turns the Lissajous elliptical and interpolation glitches - keep each differential pair together

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading