Inductive switches work on eddy currents, and plain plastic generates none - the target is simply invisible, whatever the brand. Accept the physics, then choose one of three practical routes: embed a metal tab, switch to capacitive, or go optical.
Embedding a metal tab is the cheapest and steadiest route: mould or fix a 10 by 10mm, 0.5mm-thick steel plate into the plastic part, or apply three layers of compressed aluminium foil tape. The inductive switch then works as on metal, factor 1.0. Three rules: the tab position must be tooling-controlled, since a 2mm shift moves the acting point; the tab area should cover at least half the sensing face diameter; and taped solutions need a quarterly bond check - a lifted tab means drift. For retrofit jobs this route lands within a day, which is why maintenance crews pick it first.
Capacitive sensing suits pellet levels and plastic presence on conveyors, but needs disciplined sensitivity tuning and regular cleaning in humid plants. Photoelectric units fit longer distances and precise positioning; clear plastics demand thru-beam or retroreflective types, since diffuse sensing barely sees transparency. Cost ranks tab-plus-inductive lowest, capacitive mid, photoelectric highest; maintenance ranks the same order. Document the chosen scheme with tab drawings or sensitivity settings, and label each detection point with its method so nobody re-tunes by guesswork.
| Route | Principle | Cost and upkeep | Best suited for |
|---|---|---|---|
| Metal tab plus inductive | Embedded plate or foil tape | Lowest cost, least upkeep | First choice for volume parts |
| Capacitive | Dielectric constant change | Mid cost, periodic cleaning and tuning | Levels and non-metal presence |
| Diffuse photoelectric | Reflected light received | Higher cost, window cleaning | Opaque plastic positioning |
| Thru-beam or retroreflective | Beam interrupted or folded | Highest cost, most reliable | Clear parts and long range |
| Ultrasonic | Sound ranging | Mid cost, affected by dust and airflow | Clear parts, harsh lighting |
Once the route is fixed, write it into the process file: tab position drawings, sensitivity setpoints, optical alignment bases. Re-verify on every batch or mould change from the file, not from memory. On lines mixing several methods, label each point with its method type to prevent wrong adjustments.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Proximity and photoelectric characteristics per GB/T 14048.10 (IEC 60947-5-2); machine electrical safety per GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.