Thermocouple selection starts with the calibration letter: K, S, E and J each carry their own range and accuracy strengths, and a wrong letter means blown sensors or nonsense readings. Common types compared, K-type traits and range selection below.
The type letter defines the temperature versus millivolt curve: Type K, nickel-chromium versus nickel-silicon, spans -200 to 1300 degrees Celsius with about 1100 degrees continuous duty and roughly 41µV per degree of sensitivity - high among common types, cheap, and the industrial workhorse. Type S, platinum-rhodium 10 versus platinum, covers 0~1600 degrees with excellent stability but small output around 10µV per degree and a high price, reserved for high-temperature precision. Type E delivers the largest output near 68µV per degree for fine differential measurements up to 900 degrees. Type J is economical to 750 degrees but the iron leg rusts. Compensation lead wire must match the type and polarity - mixing them injects error directly.
Type K strengths: wide range, high sensitivity, fair linearity, low cost, good oxidation resistance. Three boundaries: under reducing atmospheres or vacuum the chromium volatilises and life collapses - fit a protective sheath; sulphur environments attack the nickel leg - use sealed mineral-insulated construction; above 1100 degrees long-term drift reaches degrees per year, so above that boundary move to S or B types. Response: 3mm mineral-insulated K sensors answer in seconds for dynamic duty, assembly types with protection tubes take tens of seconds for furnace monitoring. Range selection: add 20 percent margin above the process maximum - an 800-degree furnace runs happily on a 1100-degree K type without paying for S. Verify the instrument input is configured for the same letter, connect compensation leads with matched polarity and equal temperatures at both joints, and immerse the sheath at least ten diameters past the pipe centreline so the reading represents the flow.
| Type | Materials | Range | Typical duty |
|---|---|---|---|
| Type K | NiCr-NiSi | -200~1300 degrees | General industry, first choice below 800 |
| Type S | PtRh10-Pt | 0~1600 degrees | High-temperature precision, calibration |
| Type E | NiCr-CuNi | -200~900 degrees | Fine differential, high output |
| Type J | Fe-CuNi | -40~750 degrees | Economical mid-low range |
| Type B | PtRh30-PtRh6 | 0~1700 degrees | Ultra-high temperature |
| Type T | Cu-CuNi | -200~350 degrees | Cryogenic and precision |
The selection mantra: range sets the ceiling, accuracy sets the class, atmosphere sets the sheath, and the instrument must match the letter. Type K covers four fifths of industrial duty; remember its three boundaries - reducing atmosphere, sulphur, long-term ceiling - and selection rarely goes wrong.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Thermocouple reference tables and tolerances per GB/T 16839.1 (IEC 60584-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.