A vision system that cannot keep up with the line is usually a cycle time budget that was never actually computed. Breaking one inspection into trigger, exposure, transfer, processing and output makes the arithmetic explicit and the fixes obvious.
Total time is trigger plus exposure plus transfer plus processing plus output. Triggering with a photoelectric hard trigger lands inside 1 ms and beats PLC soft triggers for jitter. Exposure is dictated by motion. Transfer runs 5 to 40 ms on GigE depending on resolution, or 1 to 3 ms on 10GigE and CoaXPress. Processing takes 5 to 50 ms on smart cameras and 1 to 20 ms on a GPU equipped PC. Output through hardware IO is under 1 ms. On a 2 second line the whole chain fits in 100 ms with room to spare; on a 200 ms high speed line every stage gets squeezed.
Exposure is bounded by motion blur: during one exposure the part must not move more than one pixel, or edges soften and algorithms fail. The rule is exposure time no more than pixel size divided by speed; at 0.1 mm per pixel and a 300 mm/s belt that is 0.33 ms. Such short exposures starve the sensor of light, so add a strobe: a 10 to 100 microsecond flash effectively becomes the exposure, freezing motion, and the camera integration can then relax. Strobing is the standard answer for moving inspection, not cranking gain and drowning features in noise.
When processing runs long, recover margin in this order: crop the region of interest for 50 percent or more savings; reduce resolution but keep 3 pixels per feature; pipeline stages so the next frame exposes while the current one processes; pick smart cameras with FPGA preprocessing; upgrade to 10GigE. Understand the failure mode: an overrun cycle does not slow the line, it silently skips parts, so the quality gate evaporates. Use hard triggers, count every trigger against product count daily, and stop the line on any mismatch, because a skipped inspection is worse than a slower one.
| Stage | Typical time | Optimisation |
|---|---|---|
| Trigger | Under 1 ms | Photoelectric hard trigger |
| Exposure | 0.1~10 ms | Strobe to lock short exposure |
| Transfer | 5~40 ms | 10GigE or CoaXPress |
| Processing | 5~50 ms | ROI crop, FPGA preprocessing |
| Output | Under 1 ms | Direct hardware IO |
| Count check | Daily | Triggers versus parts against skips |
Use this table when sizing vision systems and squeezing cycle time on the floor. Budget backwards from the line takt, honour the motion blur constraint first, then split the remainder across transfer and processing. Verify trigger counts against product counts daily and stop on any mismatch.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical safety per GB/T 5226.1 and IEC 60204-1; safety interlock acceptance per the same clauses. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.