Glass scales are precise but delicate; magnetic scales are rugged but one accuracy class lower. Their installation conditions differ enough to decide where each belongs. Four dimensions compared - accuracy, protection, gap, base surface - so selection lands right the first time.
Accuracy: linear scales deliver ±3~5µm per metre typically, ±1µm for precision grades, with 0.1~1µm resolution; magnetic scales sit around ±10µm per 300mm with micron-level resolution. Environmental robustness runs the other way: glass gratings fear contamination and demand IP64 plus air purging under coolant and dust, while magnetic scales shrug off oil and dirt but fear strong magnetic fields. Temperature: glass bases expand little, magnetic tape follows steel expansion, so long-travel thermal compensation must be computed. In one sentence: glass goes into precision machines, magnetic into rough duty.
The installation differences live in four points. Parallelism: glass 0.02~0.05mm full length, magnetic 0.1mm - more than twice as forgiving; gap: reading head 0.8~1.2mm held constant for glass, magnetic head 0.3~0.8mm tolerating larger wander; base surface: glass needs a finish-machined, stress-relieved face, magnetic tape bonds to ordinary machined surfaces; protection: glass demands seals, air purge and periodic cleaning, magnetic needs only gap checks. For long travels beyond 3m, tape-type magnetic scales are far easier - long glass scales cost and transport badly. Selection tree: better than 5µm or full-closed-loop duty picks glass; tens of microns in oily, dusty plants on a budget picks magnetic; and mixed use - glass on spindle and table, magnetic on auxiliary axes - is the value play. Remember one line each: glass installs around cleanliness and a constant gap, magnetic around gap and bracket rigidity. Their electrical standards differ (TTL or 1Vpp versus TTL square or sine-cosine), so verify parameters per scale when interfacing the CNC - never reuse one pulse equivalent across both.
| Dimension | Linear (glass) scale | Magnetic scale |
|---|---|---|
| Typical accuracy | ±3~5µm/m, ±1µm precision | ±10µm class per 300mm |
| Protection | IP64 plus air purge and cleaning | Oil and dust tolerant, nearly none |
| Parallelism | 0.02~0.05mm full length | 0.1mm full length |
| Working gap | 0.8~1.2mm, must stay constant | 0.3~0.8mm, wander tolerated |
| Base surface | Finish-machined, stress-relieved | Ordinary machined surface |
| Best duty | Full-closed-loop precision machines | Rough positioning in hostile plants |
Glass and magnetic scales are a division of labour, not substitutes: accuracy takes one, environment takes the other. Assign scale types per axis at the planning stage based on precision need and plant conditions - far cheaper than scrapping a fouled glass scale or upgrading a magnetic one for accuracy later. Keep separate installation records for gap and parallelism, because the maintenance rhythms differ too.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Selection and installation of position feedback per GB/T 5226.1 (IEC 60204-1) and related digital-measuring product standards. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.