Magnetic scales shrug off oil and dust, yet head gap and parallelism still carry hard limits - sloppy mounting loses counts just the same. Steps, gap numbers and tolerance values below, plus how they differ from glass scales.
Install in five steps: clean and level the mounting face, tensioning tape scales to the specified force; rough-fix the scale parallel to the guideway with fixing points every 100~150mm; sweep a dial indicator and hold parallelism within 0.1mm over the full length - more forgiving than the 0.05mm of glass scales because the head tolerates gap changes; fit the magnetic head and set its gap; then jog the full travel and verify counting. On tape scales press out bonding bubbles - a bubble makes the count jump at one spot.
The working gap between head and scale is the governing number: typically 0.3~0.8mm, best set at 0.5mm with plus or minus 0.1mm of variation, since wider gaps sink the signal and narrower ones risk contact. Parallelism: 0.1mm full length in the horizontal plane, 0.15mm vertical; the head bracket must be rigid - resonance in a vibrating environment produces counting glitches, so brace it and keep it away from vibration sources. Magnetic scales fear strong fields: stay 100mm from servo motors and transformers, adding mumetal shims if space is tight. After fitting, sweep the gap with a dial indicator over full travel; the variation must stay within ±0.1mm. Maintenance is light - quarterly gap checks, yearly tension and bond inspection. Fault signature differs from glass scales: lost counts trace to gap drift or loose brackets; a fixed-position anomaly marks a knocked or scratched scale section. Choose by duty: glass for precision, magnetic for hostile environments.
| Item | Value or requirement | Note |
|---|---|---|
| Head gap | 0.3~0.8mm, best 0.5mm±0.1 | Wide sinks signal, narrow risks contact |
| Parallelism | 0.1mm full length, 0.15mm vertical | Looser than glass, still sweep it |
| Fixing pitch | 100~150mm | Prevents local tape waviness |
| Strong-field distance | 100mm from motors and transformers | Mumetal shims where space is tight |
| Tape tension | Per the maker value | Slack tape makes counts jump |
| Bracket rigidity | Braced, away from vibration | Resonance causes counting glitches |
Magnetic scale installation boils down to a stable gap: set the gap, brace the bracket, avoid the fields, and the feedback serves for years. Record the measured gap and fixing layout in the archive, recheck quarterly, and a decade of trouble-free service is common.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Installation of position feedback devices per GB/T 5226.1 (IEC 60204-1) and related digital-readout installation standards. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.