Two switches both rated 5mm with double the price gap - which one? Sensing distance is only the entry ticket; switching frequency, repeatability, protection class and output type are where models really differ. A side-by-side method below.
Identical distance ratings hide seven differentiators: switching frequency, 100~500Hz on ordinary types versus 1~5kHz on high-frequency ones - a tenfold gap that decides counting duty outright; repeatability, 10 percent of distance on ordinary types against 1~3 percent on precision ones; hysteresis from 1 to 15 percent; protection IP67 versus IP68 or IP69K for long-term wet duty; housing 304 versus 316L stainless for corrosion; output form, where two-wire types bring leakage and residual-voltage constraints; and temperature range, -25 to 70 degrees versus -40 to 85 for outdoors and furnace sides.
The method is to translate the duty into a parameter priority: counting puts frequency first, positioning puts repeatability first, wet machining puts protection and material first, direct PLC drive puts leakage and residual voltage first, and outdoor or cold-store duty puts the low-temperature limit first. When two same-distance models differ by double the price, name the three parameters that justify the premium and check whether your duty actually uses them - used, they are worth it; unused, buy the economical one. Catalogues carry all of it; a five-minute comparison table settles the choice. Hidden economics matter too: metal housings with guards outlast plastic several times in clamping areas, and standardising the line on one or two models shrinks spares and swap mistakes. Run any new model a week under real duty before bulk ordering, log drift and false trips, and let the data sign the second order.
| Parameter | Ordinary type | High-performance type |
|---|---|---|
| Switching frequency | 100~500Hz | 1~5kHz |
| Repeatability | 10% of distance | 1~3% of distance |
| Hysteresis | 10~15% of distance | 1~5% of distance |
| Protection class | IP67 | IP68 or IP69K |
| Temperature range | -25~70 degrees | -40~85 degrees |
| Housing material | Nickel-plated brass | 304 or 316L stainless |
Same-distance selection means translating duty into parameter priority and picking on that priority, never on price and distance alone. Standardise models across the line, keep the comparison table in the selection archive, and every expansion reuses proven choices even with new technicians.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Performance parameters and tests per GB/T 14048.10 (IEC 60947-5-2); selection safety per GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.