Telecentric versus ordinary FA lenses: measurement accuracy compared

The same 5 MP camera can deliver an order of magnitude better measurements simply by swapping to a telecentric lens. Understanding why the parallel optical path kills magnification drift tells you exactly which tasks demand it.

1. How it works

An ordinary FA lens is a central projector: move the object along the axis and magnification follows, so a 0.5 mm mounting error shifts the scale by 1 to 2 percent and fixture height variation flows straight into results. A telecentric lens restricts the aperture so only chief rays parallel to the axis pass; object displacement no longer changes magnification, holding scale error under 0.1 percent and shrugging off plus or minus 1 mm of fixture wander. The costs are real: field of view equals sensor size divided by magnification, the barrels are bulky, prices run 3 to 10 times FA lenses, and vignetting at depth of field edges must be respected per the datasheet.

2. Numbers and practice

Concrete numbers on a 5 MP camera with 3.45 micron pixels: measuring a 50 mm part with an FA lens, a 0.5 mm distance wander moves the reading by around half a millimetre at 1 percent scale error; a double telecentric under the same condition drifts within 0.02 mm. Total error budget: interpolation near a tenth of a pixel, distortion that FA lenses suffer at 0.1 to 0.5 percent at the edges versus 0.01 to 0.05 percent for telecentrics, and scale drift itself. FA plus careful calibration reaches plus or minus 0.03 to 0.05 mm; telecentric lands at plus or minus 0.005 to 0.01 mm without per unit setup work.

3. Pitfalls and fixes

Draw the line clearly: positioning, presence, code reading and broad surface checks stay on FA lenses, cheap and flexible; every dimensional, gap and flatness measurement goes telecentric as a hard requirement. Double telecentric suits high precision dimensions and thickness; single telecentric covers most duties. On the floor, pair telecentrics with collimated backlight, since a misaligned path cancels the whole advantage; keep apertures around F8 to F16, because stopping down further invites diffraction blur; and split large fields into multiple stations rather than forcing one oversized, lower accuracy view.

4. Telecentric versus FA quick table

ItemOrdinary FA lensTelecentric lens
Optical principleCentral projection, scale follows distanceParallel chief rays, constant scale
Magnification error1~2% with setup wanderUnder 0.1%
Distortion0.1~0.5% at edges, calibrate0.01~0.05%
Measurement accuracy±0.03~0.05 mm class±0.005~0.01 mm class
PriceBaseline3~10 times
Best dutyPositioning, codes, appearanceDimension, gap, flatness

5. Notes

Use this table when reviewing lens choices for vision measurement projects. Separate measuring from recognising tasks first: measurement goes telecentric without debate, recognition stays FA. Telecentric builds need collimated backlight and a depth of field check, and quotations should declare the price gap early so precision never gets value engineered away.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: General practice per GB/T 5226.1 and IEC 60204-1; measurement system analysis per the corporate metrology system. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Forcing dimensional work onto FA lenses feeds fixture variation straight into the result
② Telecentrics without collimated backlight cancel their own advantage through path misalignment
③ One oversized telecentric view sacrifices accuracy that a split station would preserve

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.