The servo drive reports an overload code (e.g., Yaskawa AL.051, Panasonic Err21) and the motor stops.
① Acceleration/deceleration time too short, driving acceleration torque beyond the motor's maximum
② Load-to-inertia ratio exceeds the servo recommended value (generally ≤10)
③ Mechanical jam / slide carriage sticking
④ Undersized braking resistor causing overvoltage during deceleration
⑤ Undersized motor (insufficient continuous torque)
① Check the drive's actual torque monitor value (against rated torque)
② Check the drive inertia-ratio setting
③ Disconnect the load and manually turn the shaft to check mechanical resistance
④ Measure the braking resistor resistance
① Extend acceleration/deceleration time (at least 0.3~0.5s)
② Increase the reduction ratio to lower the inertia ratio
③ Check guide / ballscrew lubrication and assembly
④ Increase braking-resistor power / resistance
⑤ Use the next larger motor size
The drive reports an encoder-related alarm (position deviation / communication error).
① Encoder cable damaged / broken
② Poor encoder connector contact
③ Encoder contaminated (oil / cutting fluid ingress)
④ Encoder subject to strong EMI
⑤ Encoder itself damaged (precision optics sensitive to vibration)
① Inspect encoder cable appearance and connectors
② Use an oscilloscope to measure encoder signal waveforms
③ Substitution method (swap in a known-good encoder to test)
① Replace the encoder cable (use the original shielded cable)
② Clean and re-seat the encoder connector
③ Improve encoder mounting seal
④ Route the encoder cable in a separate metal conduit for shielding
⑤ Replace the encoder (requires re-zeroing)
The stepper motor loses pulses during operation; actual position does not match the commanded position.
① Acceleration time too short (a stepper cannot start/stop instantly)
② Operating torque exceeds the motor's torque-speed curve range
③ Drive voltage too low (below rated)
④ Motor running in the resonance-frequency region
⑤ Interference causing the driver to drop received pulses
① Lower the speed and observe whether step loss persists
② Use an oscilloscope to check the driver pulse-input waveform
③ Check the supply voltage
① Extend acceleration/deceleration time (≥0.2s)
② Check the torque-speed curve; slow down or use a larger motor
③ Raise the driver supply voltage (recommend DC24~48V)
④ Change the driver microstep setting to avoid the resonance region
⑤ Use shielded twisted-pair for the pulse lines
After energizing, the motor fails to rotate or runs at very low speed with a humming sound.
① Phase loss (blown fuse / poor contactor contact / broken wire)
② Motor winding ground fault or short
③ Load jammed
④ Faulty start capacitor (single-phase motor)
⑤ Voltage too low
① Use a multimeter to check three-phase voltage balance
② Measure three-phase winding resistance balance
③ Disconnect the load and start unloaded
① Inspect the supply circuit (fuse / contactor / thermal relay)
② Measure insulation resistance (normal >0.5MΩ)
③ Check the mechanical drive
④ Replace the start capacitor
⑤ Check the supply voltage (fluctuation within ±10%)
The bearing area runs noticeably hotter than the frame.
① Too much or too little grease (standard fill 1/3~1/2 of free space)
② Wrong grease grade (insufficient temperature rating)
③ Bearing clearance too small → thermal expansion → smaller clearance → vicious cycle
④ Belt too tight or coupling misaligned
⑤ Motor bearing subjected to axial load
① Use an infrared thermometer on the bearing housing (normal <70℃)
② Listen to the bearing (sharp squeal = poor lubrication, irregular noise = wear)
③ Measure vibration
① Replenish or reduce grease (NLGI 2~3 lithium grease)
② Use high-temperature grease (>120℃ use complex lithium grease)
③ Use a C3-clearance bearing
④ Adjust belt tension or re-align the coupling
⑤ Add a bearing thrust collar
A megger shows winding-to-ground insulation resistance below the safe value.
① Motor damp (long idle / high ambient humidity)
② Dust on winding surface absorbing moisture
③ Insulation aging (long service / overheating)
④ Cutting fluid / oil entering the motor
① Measure winding-to-ground insulation with a 500V megger
② Insulation judgment: >5MΩ good, 1~5MΩ acceptable, <1MΩ requires action, <0.5MΩ never operate
① Dry the motor (80℃ oven ×12h, or low-voltage heating current)
② Blow-clean the winding surface
③ Varnish-impregnate the windings
④ Improve the motor protection rating (IP54→IP65)
⑤ Insulation <0.5MΩ requires repair and rewinding