Common Faults · Motor Electric (Quick Reference Manual)

Motor System Servo Motor Overload Alarm

[Phenomenon]

The servo drive reports an overload code (e.g., Yaskawa AL.051, Panasonic Err21) and the motor stops.

[Possible Causes]

① Acceleration/deceleration time too short, driving acceleration torque beyond the motor's maximum

② Load-to-inertia ratio exceeds the servo recommended value (generally ≤10)

③ Mechanical jam / slide carriage sticking

④ Undersized braking resistor causing overvoltage during deceleration

⑤ Undersized motor (insufficient continuous torque)

[Diagnostic Method]

① Check the drive's actual torque monitor value (against rated torque)

② Check the drive inertia-ratio setting

③ Disconnect the load and manually turn the shaft to check mechanical resistance

④ Measure the braking resistor resistance

[Corrective Measures]

① Extend acceleration/deceleration time (at least 0.3~0.5s)

② Increase the reduction ratio to lower the inertia ratio

③ Check guide / ballscrew lubrication and assembly

④ Increase braking-resistor power / resistance

⑤ Use the next larger motor size

Motor System Servo Motor Encoder Fault

[Phenomenon]

The drive reports an encoder-related alarm (position deviation / communication error).

[Possible Causes]

① Encoder cable damaged / broken

② Poor encoder connector contact

③ Encoder contaminated (oil / cutting fluid ingress)

④ Encoder subject to strong EMI

⑤ Encoder itself damaged (precision optics sensitive to vibration)

[Diagnostic Method]

① Inspect encoder cable appearance and connectors

② Use an oscilloscope to measure encoder signal waveforms

③ Substitution method (swap in a known-good encoder to test)

[Corrective Measures]

① Replace the encoder cable (use the original shielded cable)

② Clean and re-seat the encoder connector

③ Improve encoder mounting seal

④ Route the encoder cable in a separate metal conduit for shielding

⑤ Replace the encoder (requires re-zeroing)

Motor System Stepper Motor Step Loss

[Phenomenon]

The stepper motor loses pulses during operation; actual position does not match the commanded position.

[Possible Causes]

① Acceleration time too short (a stepper cannot start/stop instantly)

② Operating torque exceeds the motor's torque-speed curve range

③ Drive voltage too low (below rated)

④ Motor running in the resonance-frequency region

⑤ Interference causing the driver to drop received pulses

[Diagnostic Method]

① Lower the speed and observe whether step loss persists

② Use an oscilloscope to check the driver pulse-input waveform

③ Check the supply voltage

[Corrective Measures]

① Extend acceleration/deceleration time (≥0.2s)

② Check the torque-speed curve; slow down or use a larger motor

③ Raise the driver supply voltage (recommend DC24~48V)

④ Change the driver microstep setting to avoid the resonance region

⑤ Use shielded twisted-pair for the pulse lines

Motor System Induction Motor Hard Starting

[Phenomenon]

After energizing, the motor fails to rotate or runs at very low speed with a humming sound.

[Possible Causes]

① Phase loss (blown fuse / poor contactor contact / broken wire)

② Motor winding ground fault or short

③ Load jammed

④ Faulty start capacitor (single-phase motor)

⑤ Voltage too low

[Diagnostic Method]

① Use a multimeter to check three-phase voltage balance

② Measure three-phase winding resistance balance

③ Disconnect the load and start unloaded

[Corrective Measures]

① Inspect the supply circuit (fuse / contactor / thermal relay)

② Measure insulation resistance (normal >0.5MΩ)

③ Check the mechanical drive

④ Replace the start capacitor

⑤ Check the supply voltage (fluctuation within ±10%)

Motor System Motor Bearing Overheating

[Phenomenon]

The bearing area runs noticeably hotter than the frame.

[Possible Causes]

① Too much or too little grease (standard fill 1/3~1/2 of free space)

② Wrong grease grade (insufficient temperature rating)

③ Bearing clearance too small → thermal expansion → smaller clearance → vicious cycle

④ Belt too tight or coupling misaligned

⑤ Motor bearing subjected to axial load

[Diagnostic Method]

① Use an infrared thermometer on the bearing housing (normal <70℃)

② Listen to the bearing (sharp squeal = poor lubrication, irregular noise = wear)

③ Measure vibration

[Corrective Measures]

① Replenish or reduce grease (NLGI 2~3 lithium grease)

② Use high-temperature grease (>120℃ use complex lithium grease)

③ Use a C3-clearance bearing

④ Adjust belt tension or re-align the coupling

⑤ Add a bearing thrust collar

Motor System Motor Insulation Resistance Drop

[Phenomenon]

A megger shows winding-to-ground insulation resistance below the safe value.

[Possible Causes]

① Motor damp (long idle / high ambient humidity)

② Dust on winding surface absorbing moisture

③ Insulation aging (long service / overheating)

④ Cutting fluid / oil entering the motor

[Diagnostic Method]

① Measure winding-to-ground insulation with a 500V megger

② Insulation judgment: >5MΩ good, 1~5MΩ acceptable, <1MΩ requires action, <0.5MΩ never operate

[Corrective Measures]

① Dry the motor (80℃ oven ×12h, or low-voltage heating current)

② Blow-clean the winding surface

③ Varnish-impregnate the windings

④ Improve the motor protection rating (IP54→IP65)

⑤ Insulation <0.5MΩ requires repair and rewinding