Knowledge Base › Common Faults › Hydraulic / Pneumatic Valves

Common Faults · Hydraulic / Pneumatic Valves (Quick-Reference Handbook)

Solenoid valve coil burnout

[Solenoid valve coil burnout]

[Phenomenon] Solenoid does not actuate / burnt smell

[Possible Causes]

(1) Coil voltage mismatch (AC220 → DC24 burnout); (2) Long energization overheating (poor cooling); (3) Inter-turn short (moisture); (4) Spool stuck (current rises → heat)

[Diagnostic Method]

(1) Measure coil resistance (normal tens~hundreds Ω / short ≈ 0 / open → ∞); (2) Check supply voltage (±10%); (3) Inspect coil appearance (blackened / bulged)

[Corrective Measures]

(1) Confirm voltage then replace coil; (2) Improve ventilation / cooling; (3) Waterproof / moisture-proof; (4) Fix spool sticking first (clean before replacing coil)

Solenoid valve spool sticking

[Solenoid valve spool sticking]

[Phenomenon] Solenoid silent / not fully actuated after energizing

[Possible Causes]

(1) Oil contamination (particles jam spool); (2) Oil aging (gum / varnish); (3) Small spool-body clearance (thermal expansion); (4) Spool burr / scratch

[Diagnostic Method]

(1) Manually push spool (feel resistance); (2) Disassemble spool to inspect (surface condition)

[Corrective Measures]

(1) Clean spool (kerosene + ultrasonic); (2) Replace hydraulic oil (≤ NAS9); (3) Add filter (≤ 10 μm); (4) Remove burr with fine sandpaper (1000#)

Cylinder seal wear

[Cylinder seal wear]

[Phenomenon] Cylinder leaks air / output drops

[Possible Causes]

(1) Poor lubrication (no lubricator); (2) Air source contamination (dust / water); (3) Wrong seal material (NBR shortens life at high temp); (4) Natural wear from long use

[Diagnostic Method]

(1) Listen / feel for air leak (at rod); (2) Measure cylinder bore (wear / scoring)

[Corrective Measures]

(1) Add lubricator (1~3 drops/min); (2) Add filter + dryer; (3) Replace with high-temp seal (FKM); (4) Replace seal (annual maintenance)

Proportional valve maladjustment

[Proportional valve maladjustment]

[Phenomenon] Proportional valve output flow / pressure not linear with input signal

[Possible Causes]

(1) Spool wear / contamination; (2) Proportional amplifier drift; (3) Sensor feedback fault; (4) Oil temperature change (viscosity change)

[Diagnostic Method]

(1) Measure input-output characteristic curve; (2) Check amplifier zero & gain; (3) Check sensor signal

[Corrective Measures]

(1) Clean proportional valve; (2) Re-calibrate amplifier (zero / gain); (3) Replace sensor; (4) Add oil-temp compensation; (5) Replace proportional valve

Servo valve jitter

[Servo valve jitter]

[Phenomenon] Servo valve output unstable / oscillating

[Possible Causes]

(1) System gain too high (large amplification); (2) Dirty oil (nozzle / flapper blocked); (3) Feedback signal noise; (4) Mechanical resonance

[Diagnostic Method]

(1) Lower amplifier gain (reduce 50% to test); (2) Check oil cleanliness (≤ NAS6); (3) Oscilloscope to view feedback signal

[Corrective Measures]

(1) Lower gain / add notch filter; (2) Replace hydraulic oil + 3 μm filter; (3) Shield feedback signal cable / filter; (4) Change mounting base to avoid resonance frequency

Cartridge valve not sealing

[Cartridge valve not sealing]

[Phenomenon] Cartridge valve leaks A → B when closed

[Possible Causes]

(1) Valve-seat seal surface wear; (2) Spool stuck (not fully closed); (3) Pilot valve internal leak (low control-chamber pressure); (4) O-ring damaged

[Diagnostic Method]

(1) Disassemble & inspect seal surface (wear / scratch); (2) Check pilot valve condition

[Corrective Measures]

(1) Lap seal surface / replace spool; (2) Clean cartridge valve; (3) Replace pilot valve / O-ring

Safety valve fails to pop

[Safety valve fails to pop]

[Phenomenon] Safety valve does not actuate when system overpressurized

[Possible Causes]

(1) Set pressure too high (> set value); (2) Spool rusted / stuck (long idle); (3) Spring failed (fatigue / corrosion)

[Diagnostic Method]

(1) Manual lever test (can it open manually); (2) Online check (hydraulic tester); (3) Disassemble spool

[Corrective Measures]

(1) Re-set pressure (nameplate value); (2) Disassemble & clean / derust; (3) Replace spring / safety valve; (4) Periodic check (every 6~12 months)

Relief valve pressure unstable

[Relief valve pressure unstable]

[Phenomenon] Pressure drifts / fluctuates after setting

[Possible Causes]

(1) Pilot valve seat wear; (2) Dirty oil (pilot orifice blocked); (3) Remote pressure line too long; (4) Spring fatigue (permanent deformation)

[Diagnostic Method]

(1) Observe pressure gauge fluctuation amplitude & frequency; (2) Disassemble pilot valve (spring / spool / seat)

[Corrective Measures]

(1) Lap seat / replace pilot spool; (2) Replace oil / clean; (3) Shorten remote line (≤ 2 m); (4) Replace pressure spring

Reducing valve outlet pressure too high

[Reducing valve outlet pressure too high]

[Phenomenon] Reducing valve outlet pressure rises uncontrollably

[Possible Causes]

(1) Pilot valve drain port blocked; (2) Spool stuck open; (3) Spring over-tightened; (4) Drain line backpressure too high

[Diagnostic Method]

(1) Measure outlet pressure (after closing downstream); (2) Listen for abnormal leak sound

[Corrective Measures]

(1) Clean pilot valve drain; (2) Clean / lap spool; (3) Re-set; (4) Drain line directly to tank (don't share with return)

Check valve fails to hold pressure

[Check valve fails to hold pressure]

[Phenomenon] Cylinder slowly descends during pressure holding

[Possible Causes]

(1) Seat wear / poor seal; (2) Spool stuck (not fully closed); (3) Spool spring broken; (4) O-ring damaged

[Diagnostic Method]

(1) Pressure-hold test (displacement within 30 min); (2) Disassemble spool / seat

[Corrective Measures]

(1) Replace check valve (lap seat); (2) Clean spool; (3) Replace spring / check valve

Pilot-operated check valve control failure

[Pilot-operated check valve control failure]

[Phenomenon] Control port pressurized but check valve does not open

[Possible Causes]

(1) Insufficient control pressure (need ≥ 0.3~0.5 MPa); (2) Control piston stuck; (3) Control port line blocked; (4) Drain port backpressure high

[Diagnostic Method]

(1) Measure control-port pressure (vs min control pressure); (2) Listen for opening sound

[Corrective Measures]

(1) Raise control pressure / use larger pilot ratio model (1:3 / 1:7); (2) Clean control piston; (3) Clear control line; (4) Drain line directly to tank

Counterbalance valve malfunction

[Counterbalance valve malfunction]

[Phenomenon] Counterbalance valve opens abnormally, causing cylinder drop

[Possible Causes]

(1) Control pressure too high (large pilot ratio); (2) Pressure spike in line; (3) Spring fatigue (lower opening pressure); (4) High oil temperature (lower viscosity)

[Diagnostic Method]

(1) Measure control-port pressure (vs set value); (2) Check oil temperature

[Corrective Measures]

(1) Use lower pilot-ratio counterbalance valve (1:3 → 1:1); (2) Add orifice in control line (kill spike); (3) Replace valve; (4) Lower oil temperature

Multi-way valve stem oil leakage

[Multi-way valve stem oil leakage]

[Phenomenon] Oil seepage at multi-way valve lever

[Possible Causes]

(1) Stem seal O-ring worn; (2) Stem surface wear / scratch; (3) O-ring groove worn (shallow)

[Diagnostic Method]

(1) Visually locate leak (at stem); (2) Inspect stem surface

[Corrective Measures]

(1) Replace stem seal O-ring; (2) Replace stem (worn surface); (3) Replace multi-way valve body

Cylinder piston rod scoring

[Cylinder piston rod scoring]

[Phenomenon] Longitudinal scratches / grooves on rod surface

[Possible Causes]

(1) Rod wiper seal failed (hard particles enter); (2) Low rod hardness; (3) Guide bushing wear (rod eccentric wear); (4) Hard particles in oil

[Diagnostic Method]

(1) Visually check scoring depth & extent; (2) Check wiper seal (lip notch)

[Corrective Measures]

(1) Replace rod (replate / new); (2) Replace wiper / seal; (3) Check bushing clearance; (4) Replace oil / add filter

Cylinder cushion failure

[Cylinder cushion failure]

[Phenomenon] Impact at end of stroke

[Possible Causes]

(1) Cushion plunger / sleeve wear; (2) Cushion adjusting screw loose / skewed; (3) Cushion check valve damaged; (4) Cushion pressure set too high / low

[Diagnostic Method]

(1) Adjust cushion screw (clockwise → more cushion); (2) Listen for end impact

[Corrective Measures]

(1) Replace cushion plunger / sleeve; (2) Re-adjust cushion screw; (3) Replace cushion check valve; (4) Adjust gradually to smooth