Knowledge Base › Common Faults › Electrical Faults

Common Faults · Electrical Faults (Quick Reference Manual)

PLC Communication Interruption: Analysis and Handling

[Phenomenon]

PLC fails to communicate with host computer / touchscreen

[Possible Causes]

① Communication cable broken / connector loose

② Communication parameters mismatch (baud rate / parity / station number)

③ Communication module failure

④ Electromagnetic interference

⑤ Communication distance exceeded

[Diagnostic Method]

① Check communication indicator lights

② Connect PC directly to PLC to test communication

③ Check communication parameter settings

[Corrective Measures]

① Inspect cable and connectors

② Unify communication parameter settings

③ Replace communication module

④ Use shielded twisted pair for communication line and ground it

⑤ Add repeater or switch to RS485 / Ethernet

Touchscreen Unresponsive: Analysis and Handling

[Phenomenon]

Touchscreen black screen / white screen / no touch response

[Possible Causes]

① Power supply failure (DC24V output abnormal)

② Backlight damaged

③ Touch panel damaged (cracked screen)

④ Main board failure

⑤ Setting parameters incorrect

[Diagnostic Method]

① Check power indicator and output voltage

② Check whether screen displays

③ Restart touchscreen

[Corrective Measures]

① Repair power supply

② Replace backlight

③ Replace touch panel

④ Replace main board or whole unit

⑤ Reconfigure or restore factory settings

VFD Overcurrent: Analysis and Handling

[Phenomenon]

VFD reports OC fault on start or during operation

[Possible Causes]

① Acceleration time too short

② Motor / cable short-circuit or ground fault

③ Motor parameters set incorrectly vs actual

④ Sudden load change (jamming)

⑤ VFD capacity too small

[Diagnostic Method]

① Check fault code

② Disconnect motor and run unloaded to judge

③ Measure motor insulation

[Corrective Measures]

① Extend acceleration time

② Check motor insulation

③ Input motor parameters correctly

④ Inspect load

⑤ Use larger VFD

VFD Overvoltage: Analysis and Handling

[Phenomenon]

VFD reports OV fault during deceleration

[Possible Causes]

① Deceleration time too short

② Braking resistor value too high or not connected

③ Load inertia large

④ Grid voltage too high

[Diagnostic Method]

① Check fault log

② Measure DC bus voltage

③ Check braking resistor wiring

[Corrective Measures]

① Extend deceleration time

② Reduce braking resistor or increase power

③ Add braking unit

④ Check grid voltage

Relay Contact Welding: Analysis and Handling

[Phenomenon]

Contacts still conduct after relay de-energizes

[Possible Causes]

① Load current too high (exceeds contact rating)

② Inductive load without arc suppression

③ Contact carbon buildup

④ Frequent start/stop

⑤ Spring fatigue

[Diagnostic Method]

① Power off and measure contact on/off

② Check whether load current exceeds limit

[Corrective Measures]

① Derate or use larger contactor

② Add RC snubber circuit or varistor

③ Replace contacts

④ Switch to solid-state relay

⑤ Replace relay

Circuit Breaker Tripping: Analysis and Handling

[Phenomenon]

Breaker won't close or trips during operation

[Possible Causes]

① Line short-circuit (neutral-live / phase-to-phase)

② Load too large (exceeds breaker rating)

③ Leakage (residual-current breaker)

④ Breaker itself faulty

⑤ Instantaneous current surge

[Diagnostic Method]

① Disconnect load and see if it closes

② Use megger to measure line insulation

③ Use clamp meter to measure load current

[Corrective Measures]

① Locate and repair short-circuit point

② Reduce load or use larger breaker

③ Check line insulation

④ Replace breaker

⑤ Switch to Type D curve breaker (surge-resistant)

Contactor Abnormal Noise: Analysis and Handling

[Phenomenon]

Contactor buzzes after closing

[Possible Causes]

① Iron core mating face has oil / dust

② Short-circuit ring broken

③ Voltage too low, incomplete closing

④ Moving iron core stuck

[Diagnostic Method]

① Judge by sound (buzzing = core problem)

② Check cleanliness of mating face

③ Measure control voltage

[Corrective Measures]

① Clean iron core mating face

② Replace short-circuit ring or contactor

③ Keep voltage at 85~110% of rated

④ Remove stuck object

Switching Power Supply No Output: Analysis and Handling

[Phenomenon]

DC24V power indicator off, no output

[Possible Causes]

① Input power failure (AC220V lost / fuse blown)

② Output overload / short-circuit (protection lockout)

③ Power module damaged

④ Terminal block loose

[Diagnostic Method]

① Measure whether AC220V is present at input

② Disconnect output load and measure output

③ Check fuse

[Corrective Measures]

① Check input power

② Clear output short, power off and restart (supply has auto-recovery)

③ Replace switching power supply

④ Tighten terminals

Sensor Power Supply Fault: Analysis and Handling

[Phenomenon]

Multiple sensors lose output simultaneously

[Possible Causes]

① Shared sensor power supply faulty (switching supply failed)

② Power wire broken / fuse blown

③ Supply line short-circuit and tripped

④ Terminal block loose

[Diagnostic Method]

① Measure supply output voltage

② Check power indicator

③ Measure supply line in sections

[Corrective Measures]

① Replace / repair switching supply

② Replace fuse

③ Locate short-circuit point

④ Tighten all terminals

Emergency Stop Circuit Fault: Analysis and Handling

[Phenomenon]

Equipment fails to stop after E-stop pressed, or fails to start after E-stop reset

[Possible Causes]

① E-stop button contacts welded / damaged

② E-stop circuit wiring loose

③ Safety relay fault

④ PLC E-stop input point damaged

⑤ E-stop circuit poorly designed (asymmetric dual-channel)

[Diagnostic Method]

① Measure E-stop button contact on/off

② Check safety relay status indicator

③ Check PLC E-stop input signal

[Corrective Measures]

① Replace E-stop button

② Inspect and tighten wiring

③ Reset or replace safety relay

④ Replace PLC input module

⑤ Rework dual-channel E-stop circuit per safety standard

Servo Motor Overload Alarm

[Servo Motor Overload Alarm]

[Symptom] Drive reports overload code (Err12 / AL021, etc.), motor stops

[Possible Causes]

① Acceleration/deceleration time too short (accel torque exceeds max torque); ② load inertia ratio exceeds recommended value (> 10); ③ mechanical jam (guide / ballscrew stuck); ④ braking resistor capacity insufficient (overvoltage during decel)

[Diagnostic Method]

① Check drive's actual torque monitor value; ② calculate inertia ratio = load inertia / rotor inertia; ③ disconnect load and turn shaft by hand (high resistance means mechanical jam)

[Corrective Measures]

① Extend accel/decel time (at least 0.3~0.5 s); ② increase reduction ratio (lower inertia ratio); ③ check guide / ballscrew lubrication and assembly; ④ increase braking resistor power / resistance

Encoder Fault (Position Loss)

[Encoder Fault (Position Loss)]

[Symptom] Servo drive reports encoder alarm, motor position drifts

[Possible Causes]

① Encoder cable poor contact (loose plug); ② encoder contaminated by oil / water / dust; ③ encoder internal damage (code disc broken); ④ cable too long, signal attenuation (> 50 m)

[Diagnostic Method]

① Re-plug encoder connector (confirm locked); ② check encoder-drive communication (oscilloscope waveform); ③ swap encoder to test

[Corrective Measures]

① Lock encoder connector / replace cable; ② add encoder protective cover (waterproof / oil-proof); ③ replace encoder or motor; ④ encoder cable length ≤ 50 m (add repeater)

Stepper Motor Step Loss

[Stepper Motor Step Loss]

[Symptom] Large deviation between actual and commanded stepper position

[Possible Causes]

① Accel time too short (start frequency exceeds self-start freq); ② load too large (exceeds motor max torque); ③ driver current set too low; ④ microstep count too high (high-speed torque loss)

[Diagnostic Method]

① Mark the stop position (check if step loss always occurs at same position); ② measure driver's actual output current; ③ run at lower speed to test

[Corrective Measures]

① Extend accel/decel time (trapezoidal profile); ② increase reduction ratio / use larger motor; ③ raise driver current (≤ 1.2× motor rated current); ④ lower microstep count appropriately (≤ 16)

Motor Hard to Start

[Motor Hard to Start]

[Symptom] Motor buzzes but does not turn after energized

[Possible Causes]

① Phase loss (3-phase motor); ② voltage too low; ③ start capacitor damaged (single-phase motor); ④ rotor stuck / bearing seized

[Diagnostic Method]

① Measure whether 3-phase voltage balanced; ② turn shaft by hand (check for jam); ③ measure start capacitor capacitance

[Corrective Measures]

① Check power cable / contactor / thermal relay (phase-loss protection); ② check supply voltage (±10%); ③ replace start capacitor (capacitance drop); ④ replace motor bearings

Motor Bearing Overheating

[Motor Bearing Overheating]

[Symptom] Motor bearing housing temperature > 80°C

[Possible Causes]

① Too much / too little / degraded grease; ② improper bearing clearance (excessive preload); ③ belt too tight (large radial force); ④ poor alignment between motor shaft and driven shaft

[Diagnostic Method]

① Measure bearing housing temp (IR thermometer); ② listen to bearing sound (hissing / clicking); ③ check belt tension

[Corrective Measures]

① Fill appropriate grease (1/3~1/2 of cavity); ② use correct-clearance bearing (C3/CM); ③ adjust belt tension (deflection method); ④ re-align coupling (concentricity ≤ 0.05 mm)

Motor Insulation Resistance Drop

[Motor Insulation Resistance Drop]

[Symptom] Ground insulation < 1 MΩ

[Possible Causes]

① Motor damp (long idle / humid environment); ② winding end dust buildup (conductive); ③ insulation aging (running > 20 years); ④ water in winding (poor seal)

[Diagnostic Method]

① Use megger (500 V) to measure ground resistance; ② measure absorption ratio (R60/R15 should be ≥ 1.3)

[Corrective Measures]

① Bake dry (80~100°C × 12 h); ② clean winding end dust (vacuum + compressed air); ③ dip in insulating varnish / replace motor; ④ replace seals

Motor Three-phase Current Imbalance

[Motor Three-phase Current Imbalance]

[Symptom] Three-phase current deviation > 10%

[Possible Causes]

① Supply 3-phase voltage imbalance (> 2%); ② motor winding interturn short; ③ poor motor wiring contact (loose terminal); ④ large resistance deviation in one motor phase

[Diagnostic Method]

① Measure 3-phase supply voltage; ② measure 3-phase winding DC resistance (compare); ③ measure 3-phase current (clamp meter)

[Corrective Measures]

① Check supply / transformer 3-phase load balance; ② interturn short needs rewinding / motor replacement; ③ clean and lock terminals; ④ phase resistance deviation > 2% requires motor replacement

Motor Vibration Exceeds Limit

[Motor Vibration Exceeds Limit]

[Symptom] Motor vibration > 5 mm/s (ISO 10816)

[Possible Causes]

① Poor rotor dynamic balance (excess unbalance); ② coupling misalignment; ③ foundation bolts loose; ④ bearing wear; ⑤ electromagnetic vibration (phase loss / interturn short)

[Diagnostic Method]

① Measure vibration (accelerometer / vibrometer); ② check foundation bolts; ③ run motor uncoupled (judge motor vs load side)

[Corrective Measures]

① Balance rotor (grade G2.5); ② re-align (laser aligner / dial indicator); ③ tighten bolts / add shims; ④ replace bearing; ⑤ check supply and windings

VFD Overcurrent Alarm

[VFD Overcurrent Alarm]

[Symptom] VFD reports overcurrent during operation

[Possible Causes]

① Accel/decel time too short; ② sudden load change (jam / impact); ③ VFD capacity too small; ④ motor insulation damaged (ground short); ⑤ VFD output phase loss

[Diagnostic Method]

① Check VFD output frequency and current at overcurrent; ② run motor unloaded to test

[Corrective Measures]

① Extend accel/decel time (0.5~3 s); ② check mechanical transmission (turns freely?); ③ increase VFD capacity (one size); ④ measure motor insulation resistance; ⑤ check VFD output wiring

VFD Overvoltage Alarm

[VFD Overvoltage Alarm]

[Symptom] VFD reports overvoltage during deceleration

[Possible Causes]

① Decel time too short (large regen energy); ② braking resistor not connected / value too high; ③ braking unit damaged; ④ supply voltage too high

[Diagnostic Method]

① Check braking resistor connection; ② test by extending decel time; ③ measure DC bus voltage

[Corrective Measures]

① Extend decel time (critical for high-inertia loads); ② add / replace braking resistor (value per VFD manual); ③ replace braking unit; ④ add input reactor

PLC Communication Interruption

[PLC Communication Interruption]

[Symptom] PLC communication with host / touchscreen / VFD frequently drops

[Possible Causes]

① Communication cable interfered (shared conduit with power cable); ② comm baud rate mismatch; ③ terminator resistor missing (RS485); ④ comm port hardware damaged

[Diagnostic Method]

① Check cable routing (away from power lines); ② verify each device's comm parameters; ③ add RS485 end terminator (120 Ω)

[Corrective Measures]

① Ground cable shield at single end; ② unify comm parameters (baud / data bits / parity); ③ add signal isolator / repeater; ④ replace comm port / module

Touchscreen Unresponsive

[Touchscreen Unresponsive]

[Symptom] Touchscreen tap has no response or is sluggish

[Possible Causes]

① Touchscreen calibration lost (screen replaced); ② touch surface has oil / water stain; ③ touch connection cable loose; ④ touchscreen main board fault

[Diagnostic Method]

① Recalibrate touchscreen (in system menu); ② clean screen surface; ③ check touchscreen-to-board ribbon connection

[Corrective Measures]

① Recalibrate touch (4-point); ② clean screen (neutral cleaner); ③ re-seat touch ribbon; ④ replace touchscreen / main board

Contactor Abnormal Noise

[Contactor Abnormal Noise]

[Symptom] Contactor makes buzzing / chattering during operation

[Possible Causes]

① Supply voltage too low (magnetic pull insufficient); ② iron core surface has oil / debris (poor mating); ③ short-circuit ring broken (single-phase hum); ④ contacts burnt / poor contact

[Diagnostic Method]

① Measure coil voltage (should be 85~110% Us); ② listen (pure hum → short-ring; chatter → low voltage)

[Corrective Measures]

① Check supply voltage (add regulator); ② clean core surface (no oil / anticorrosive paint); ③ replace short-ring or contactor; ④ replace contacts / contactor

Thermal Relay Nuisance Trip

[Thermal Relay Nuisance Trip]

[Symptom] Motor current normal but thermal relay trips frequently

[Possible Causes]

① Setting current too low (mismatch with motor rated); ② ambient too hot (relay derating); ③ 3-phase imbalance (zero-sequence current trips); ④ wrong relay type (mismatch with motor start profile)

[Diagnostic Method]

① Verify setting vs motor nameplate; ② measure ambient temp; ③ measure 3-phase current balance

[Corrective Measures]

① Re-set current (1.0~1.05× motor rated); ② keep relay away from heat; ③ improve 3-phase balance; ④ use electronic thermal relay for heavy-start motors

Circuit Breaker Trips Without Cause

[Circuit Breaker Trips Without Cause]

[Symptom] Breaker trips during normal operation

[Possible Causes]

① Breaker capacity too small (load grew); ② leakage protection tripped (wiring insulation drop); ③ short-circuit (worn / damp wiring); ④ breaker itself faulty (thermal trip aged)

[Diagnostic Method]

① Measure actual line current; ② test line insulation; ③ isolate circuits one by one (find which trips)

[Corrective Measures]

① Use larger breaker (one size up); ② find leakage point / replace wiring; ③ clear short-circuit; ④ replace breaker

Switching Power Supply Overheating

[Switching Power Supply Overheating]

[Symptom] Switching supply case temp > 70°C

[Possible Causes]

① Load exceeds supply rated power; ② poor cooling (poor ventilation / dust); ③ high ambient temp; ④ switching transistor aged (efficiency drop)

[Diagnostic Method]

① Measure actual output current (vs rated); ② check mounting (cooling condition); ③ measure input voltage

[Corrective Measures]

① Use higher-power supply (margin ≥ 30%); ② improve ventilation (relocate / add fan); ③ lower ambient temp; ④ replace supply

Relay Contact Welding

[Relay Contact Welding]

[Symptom] Contacts do not release / load does not stop after relay de-energizes

[Possible Causes]

① Contact capacity insufficient (long overload); ② load is inductive (large arc); ③ contact gap carbonized; ④ spring fatigue failure

[Diagnostic Method]

① Measure contact resistance (should be < 100 mΩ); ② visually inspect contact surface; ③ check release voltage (should be > 10% Us)

[Corrective Measures]

① Use one-size-larger relay / contactor; ② add arc-suppression RC or varistor; ③ replace relay; ④ replace spring / relay

Proximity Switch False Trigger

[Proximity Switch False Trigger]

[Symptom] Proximity switch outputs with no target present

[Possible Causes]

① Mounted too close (> 50% of range); ② adjacent sensors interfere; ③ target is ferromagnetic (counts even when close); ④ power interference (high ripple)

[Diagnostic Method]

① Measure actual mounting distance; ② remove target and check reset; ③ scope power ripple

[Corrective Measures]

① Adjust mounting distance (keep safe distance); ② spacing ≥ 3× detection diameter; ③ use shielded sensor; ④ add filter / separate supply

Photoelectric Switch Slow Response

[Photoelectric Switch Slow Response]

[Symptom] Photoelectric switch misses object passing detection zone

[Possible Causes]

① Response time longer than object transit time; ② object transparent / translucent (diffuse type); ③ lens dust / contamination; ④ one end of through-beam offset

[Diagnostic Method]

① Calculate transit time (speed × detection width); ② check lens cleanliness; ③ check through-beam alignment

[Corrective Measures]

① Use faster photoelectric switch (0.5 ms); ② use through-beam or fiber for transparent objects; ③ clean lens (lens cloth + alcohol); ④ re-align emitter/receiver

Pressure Sensor Zero Drift

[Pressure Sensor Zero Drift]

[Symptom] Sensor outputs signal at zero pressure

[Possible Causes]

① Zero offset after long use; ② mounting stress (over-torque); ③ diaphragm deformed (overload); ④ temperature change (thermal zero drift)

[Diagnostic Method]

① Remove sensor (measure output at zero pressure); ② check torque (per manual); ③ zero-calibrate (electrical)

[Corrective Measures]

① Electrical zero (zero pot to 0 output); ② install with torque wrench; ③ replace sensor (overload damage); ④ use low-drift sensor (±0.02%/°C)

Temperature Sensor Slow Response

[Temperature Sensor Slow Response]

[Symptom] Sensor output lags noticeably after temperature change

[Possible Causes]

① Large package thermal mass (long response); ② poor mounting (sheath-medium contact poor); ③ probe fouling / coking

[Diagnostic Method]

① Check datasheet (response time τ); ② check insertion depth (to medium center)

[Corrective Measures]

① Use faster sensor (thermocouple < RTD < thermistor); ② add thermal grease (probe-sheath); ③ clean probe surface; ④ deeper install (≥ 1/3 pipe dia)

Displacement Sensor Out of Tolerance

[Displacement Sensor Out of Tolerance]

[Symptom] Large deviation between reading and actual displacement

[Possible Causes]

① Sensor tilted (cosine error); ② detection surface uneven / not perpendicular; ③ poor linearity (range exceeds rated stroke); ④ large ambient temperature change

[Diagnostic Method]

① Calibrate vs gauge block / micrometer; ② check mounting angle

[Corrective Measures]

① Adjust mounting (axis ∥ motion); ② add bracket / adjust surface; ③ stay within rated range; ④ add temp compensation / low-drift sensor

Torque Sensor Unstable Signal

[Torque Sensor Unstable Signal]

[Symptom] Large torque reading fluctuation

[Possible Causes]

① Coupling misalignment (adds bending moment); ② unstable supply (high ripple); ③ used beyond range (nonlinear); ④ strong magnetic interference nearby (VFD / motor)

[Diagnostic Method]

① Check zero drift unloaded; ② scope power ripple; ③ check range utilization

[Corrective Measures]

① Re-align coupling (concentricity ≤ 0.05 mm); ② add regulated supply / filter; ③ stay within range (20% margin); ④ shield sensor / keep from VFD

Load Cell Creep Exceeds Limit

[Load Cell Creep Exceeds Limit]

[Symptom] Output keeps changing under constant load (> 0.05%/30min)

[Possible Causes]

① Elastic element material creep (stress relief); ② overload (plastic deformation); ③ unstable base (deformation); ④ junction box damp (resistance change)

[Diagnostic Method]

① Record 60-min output under constant load; ② inspect appearance (deformation); ③ measure bridge resistance

[Corrective Measures]

① Replace sensor (creep irreversible); ② confirm load within range (incl. shock); ③ reinforce base (rigid); ④ dry junction box / add sealant

Laser Sensor Safety Interlock Failure

[Laser Sensor Safety Interlock Failure]

[Symptom] Laser safety sensor fails to trigger in unsafe state

[Possible Causes]

① Sensor position shifted; ② sensor faulty / aged; ③ reflector moved / dirty; ④ safety relay fault

[Diagnostic Method]

① Manually block beam to test; ② check safety relay status; ③ check reflector position

[Corrective Measures]

① Recalibrate sensor position; ② replace sensor (safety category III); ③ fix / clean reflector; ④ replace safety relay; ⑤ periodic functional test (daily)

Safety Light Curtain / Grid Fails to Actuate

[Safety Light Curtain / Grid Fails to Actuate]

[Symptom] No output signal after beam blocked

[Possible Causes]

① Misalignment (emitter/receiver offset); ② curtain surface contaminated; ③ sync line / cable loose; ④ controller fault

[Diagnostic Method]

① Check emitter/receiver indicators; ② block each beam (find which fails); ③ check wiring

[Corrective Measures]

① Re-align (emitter green); ② clean protection window (lens cloth); ③ lock cable connectors; ④ replace controller / curtain

Ultrasonic Sensor Large Blind Zone

[Ultrasonic Sensor Large Blind Zone]

[Symptom] Near-field (< 100 mm) detection blind zone

[Possible Causes]

① Wrong sensor choice (ultrasonic has blind zone); ② low frequency (large blind zone); ③ mounted too close to target

[Diagnostic Method]

① Check datasheet (blind zone); ② adjust mounting distance (increase)

[Corrective Measures]

① Use higher-frequency ultrasonic (higher freq → smaller blind zone); ② keep distance > blind zone; ③ if unavoidable, mount at angle

Color-mark Sensor Misjudgment

[Color-mark Sensor Misjudgment]

[Symptom] Color-mark sensor cannot distinguish colors

[Possible Causes]

① Insufficient color contrast (ΔE < 10%); ② improper detection distance; ③ wrong light color (white / RGB choice); ④ ambient light interference (sunlight / lighting)

[Diagnostic Method]

① Use built-in teach function; ② tune detection distance to best (lamp on); ③ compare signal strength under light colors

[Corrective Measures]

① Increase mark-background contrast (high-contrast color); ② precisely tune distance (max signal); ③ choose matching light color; ④ add light shield

Fiber Sensor Insufficient Sensitivity

[Fiber Sensor Insufficient Sensitivity]

[Symptom] Fiber amplifier unstable / misses target

[Possible Causes]

① Fiber head contaminated / damaged (end worn); ② distance too far (beyond amplifier); ③ head not perpendicular to target; ④ sensitivity set too low

[Diagnostic Method]

① Clean fiber end (anhydrous alcohol); ② check amplifier margin (should be ≥ 2×); ③ check head angle

[Corrective Measures]

① Replace head / cut front end (remove contaminated part); ② shorten distance; ③ adjust head (perpendicular); ④ raise amplifier sensitivity / threshold

Other quick references in this series:Welding defectsHydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsQuick diagnosisMechanical component faultsBearing faultsGear faultsHydraulic / pneumatic valves