Bearing temperature clearly above normal (exceeds 80°C)
(1) Too much or too little grease
(2) Wrong grease grade (insufficient heat resistance)
(3) Too-small bearing clearance → heat expansion → smaller clearance → vicious cycle
(4) Excessive preload (angular-contact bearing)
(5) Misalignment → additional load
(6) Seal friction too high
(7) Poor bearing-housing heat dissipation
(1) Measure temperature: normal < 70°C, warning 70~80°C, danger > 80°C
(2) Listen: smooth & steady is normal, sharp whistle / irregular noise → stop
(3) Measure vibration: increased vibration may indicate cage or rolling-element damage
(1) Check grease fill (1/3~1/2 of cavity)
(2) Use proper grease grade (lithium / complex lithium, etc.)
(3) Select C3 / C4 clearance
(4) Adjust preload
(5) Check installation alignment
Other related quick references:Welding defectsHydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisMechanical component faultsGear faultsHydraulic / pneumatic valves