Knowledge Base › Common Faults › Motor Failure

Common Faults · Motor Failure (Quick Reference Manual)

Hard Motor Starting

[Phenomenon]

After energizing, the motor fails to rotate or runs at very low speed with a humming sound; the thermal relay may trip.

[Possible Causes]

① Phase loss (blown fuse / poor contactor contact / broken wire)

② Motor winding ground fault or turn-to-turn short

③ Load mechanically jammed (seized bearing / foreign object blockage)

④ Faulty start capacitor (single-phase motor)

⑤ Supply voltage too low (below 85% of rated)

[Diagnostic Method]

① Use a multimeter to check three-phase voltage balance (difference ≤10V)

② Disconnect the load and run a no-load start to determine whether the problem is the motor or the load

③ Measure three-phase winding resistance balance (difference ≤2%)

④ Measure insulation resistance (should be >0.5MΩ)

[Corrective Measures]

① Inspect the supply circuit (fuse / contactor / thermal relay / wiring)

② If the winding is burned out, send it for repair and rewinding

③ Check the mechanical drive (bearing / coupling / belt)

④ Replace the start capacitor with the same specification

⑤ Install a voltage stabilizer or check the supply wiring

Unbalanced Motor Operating Current

[Phenomenon]

Three-phase current imbalance exceeds 10%; the motor vibrates and overheats, and prolonged operation may burn out the windings.

[Possible Causes]

① Unbalanced three-phase supply voltage

② Motor winding turn-to-turn short

③ Incorrect motor wiring (star connected as delta, or reversed)

④ Poor contactor contact (loose connection on one phase)

[Diagnostic Method]

① Measure three-phase current with a clamp meter (measure after stopping then restarting)

② Measure and compare the three-phase voltages

③ Measure the DC resistance of each winding phase

[Corrective Measures]

① Check whether the three-phase load on the supply network is balanced

② Send for repair and inspect the windings

③ Wire correctly per the nameplate

④ Replace or repair the contactor

Reduced Motor Insulation Resistance

[Phenomenon]

A 500V megger shows winding-to-ground insulation <1MΩ, indicating leakage.

[Possible Causes]

① Motor damp (long idle period / ambient humidity >90% / water ingress)

② Dust on winding surface absorbing moisture

③ Insulation aging (exceeded service life / prolonged overheating)

④ Cutting fluid / oil entering the motor terminal box

[Diagnostic Method]

① Measure insulation resistance (good >5MΩ, caution 1~5MΩ, danger <1MΩ, never operate below <0.5MΩ)

② If possible, measure the absorption ratio (R60/R15 >1.3 indicates good condition)

[Corrective Measures]

① Dry the motor (oven at 80℃ for 12h, or low-voltage heating)

② Blow-clean dust from the winding surface

③ Insulation <0.5MΩ requires repair

④ Improve the motor protection rating (e.g., IP54 to IP65)

Excessive Motor Vibration

[Phenomenon]

Operating vibration exceeds ISO 2373; bearing-housing vibration >1.8mm/s.

[Possible Causes]

① Poor rotor dynamic balance (balance weight loosened after long operation)

② Poor motor-to-load alignment (coupling coaxiality >0.1mm)

③ Bearing wear increasing clearance

④ Loose or insufficiently rigid mounting base

⑤ Electromagnetic imbalance (uneven air gap)

[Diagnostic Method]

① Measure vibration velocity with a vibrometer (normal <1.8mm/s, caution 1.8~4.5, danger >4.5)

② Distinguish bearing vibration from electromagnetic vibration (vibration stops immediately after power-off = electromagnetic issue)

③ Check coupling alignment

[Corrective Measures]

① Perform dynamic balancing

② Realign the coupling (laser aligner accuracy 0.01mm)

③ Replace the bearing

④ Reinforce the mounting base

⑤ Replace the worn bearing or adjust the air gap

Rotor Rub

[Phenomenon]

Metallic friction noise during operation, scrape marks on the stator bore, and smoke in severe cases.

[Possible Causes]

① Severe bearing wear (radial clearance out of tolerance)

② Worn or deformed end-cover register

③ Bent rotor shaft

④ Loose or shifted stator core

[Diagnostic Method]

① Identify by sound (periodic metallic friction)

② Disassemble and measure the air gap (uniformity deviation >10% is abnormal)

③ Check the bearing radial clearance

[Corrective Measures]

① Replace the bearing

② Replace the end cover or repair the register with a sleeve

③ Straighten or replace the rotor shaft

④ Tighten the core clamping bolts

Motor Encoder Fault

[Phenomenon]

The drive reports an encoder alarm (excessive position deviation / communication error / broken wire) and position control is lost.

[Possible Causes]

① Encoder cable damaged / broken / loose connector

② Encoder contaminated by oil / cutting fluid

③ Encoder subject to strong EMI (routed in the same channel as power cables)

④ Encoder glass code disk cracked by vibration

[Diagnostic Method]

① Inspect encoder cable appearance and connectors

② Use an oscilloscope to check encoder A/B/Z signal waveforms

③ Substitution method (swap in a known-good encoder to test)

[Corrective Measures]

① Replace the encoder cable (must use the original shielded cable, routed separately in a metal conduit)

② Clean the encoder or replace the seal

③ Keep the encoder cable away from power cables (distance ≥300mm)

④ Replace the encoder (requires re-zeroing / homing)

Motor Brake Fault

[Phenomenon]

Servo motor brake fails to release or cannot hold; the Z-axis drifts.

[Possible Causes]

① Brake coil burned out (resistance open or shorted)

② Brake rectifier module damaged (no DC output)

③ Brake pad worn beyond limit

④ No brake release signal (relay / PLC output fault)

[Diagnostic Method]

① Measure brake coil resistance (compare with datasheet)

② Check the brake rectifier input/output

③ Manually release the brake and check pad thickness

[Corrective Measures]

① Replace the brake coil or brake assembly

② Replace the rectifier module

③ Replace the brake pads

④ Inspect the brake control circuit (intermediate relay / SSR / PLC output point)

Broken Motor Power Cable

[Phenomenon]

The motor runs with phase loss: speed drops, vibration rises, and current is abnormal.

[Possible Causes]

① Motor cable abraded and broken (drag chain / frequent flexing at moving parts)

② Loose, overheated, or oxidized terminals

③ Power-cable joint pulled apart

[Diagnostic Method]

① With power off, measure three-phase winding DC resistance

② With power on, measure three-phase current

③ Shake the cable and observe whether the motor jitters

[Corrective Measures]

① Replace the entire power cable (joints are failure-prone)

② Re-strip, crimp, and tighten the terminals

③ Check cable protection at moving parts

Motor Overload Protection Tripping

[Phenomenon]

The thermal relay / motor protector trips and the equipment stops.

[Possible Causes]

① Actual load exceeds motor rated power

② Mechanical drive jamming (bearing / guide / ballscrew issue)

③ Thermal relay setting too low

④ Frequent motor start/stop (more than 6 times per hour)

⑤ Low voltage driving up current

[Diagnostic Method]

① Use a clamp meter to measure operating current (compare with rated)

② Manually turn the shaft to check mechanical resistance

③ Check the thermal relay setting

[Corrective Measures]

① Use a larger motor or reduce the load

② Inspect and repair the mechanical drive

③ Set the thermal relay to the motor rated current (1.0~1.1×)

④ Lengthen run/stop intervals

⑤ Check the supply voltage

Motor Cooling Fan Fault

[Phenomenon]

Motor temperature rises; the fan does not turn or is noisy.

[Possible Causes]

① Fan blade broken / deformed

② Fan guard clogged (dust / lint)

③ Fan motor burned out (separate fan motor)

④ Air duct blocked

[Diagnostic Method]

① Check whether the fan turns

② Listen for abnormal fan noise

③ Measure motor surface temperature

[Corrective Measures]

① Replace the fan blade

② Clean the fan guard and air duct

③ Repair or replace the fan motor

④ Regularly clean the motor heat-sink fins

Motor Bearing Abnormal Noise

[Phenomenon]

During operation the bearing emits metallic friction / irregular / clicking sounds.

[Possible Causes]

① Grease dried out (sharp friction sound)

② Cage damaged (clicking sound)

③ Rolling elements worn or fractured (irregular dull sound)

④ Excessive bearing clearance (humming sound)

⑤ Bearing misaligned during installation

[Diagnostic Method]

① Use a listening rod / electronic stethoscope to identify the noise type

② Measure vibration

③ Disassemble and inspect the bearing raceway and rolling elements

[Corrective Measures]

① Replenish or replace grease (NLGI2 lithium grease, fill 1/3~1/2)

② Replace the bearing

③ Replace the bearing

④ Use a C3-clearance bearing

⑤ Check bearing-housing and end-cover fit

Motor Overtemperature

[Phenomenon]

Motor surface temperature exceeds the nameplate allowable rise; too hot to touch and hold.

[Possible Causes]

① Overload (operating current > rated)

② Poor heat dissipation (fan failed / duct blocked / poor ventilation)

③ Ambient temperature too high (>40℃)

④ Voltage too high or too low

⑤ Frequent start/stop or forward/reverse operation

[Diagnostic Method]

① Measure operating current against rated

② Measure motor surface temperature (Class A ≤80℃, Class E ≤95℃, Class B ≤105℃)

③ Check ventilation and heat dissipation

[Corrective Measures]

① Reduce load or use a larger motor

② Clear the duct and repair the fan

③ Improve ventilation or add a forced cooling fan

④ Check the supply voltage

⑤ Reduce start/stop frequency

Motor Wiring Error

[Phenomenon]

Motor runs in reverse or the star-delta start sequence is wrong.

[Possible Causes]

① Three-phase supply phase sequence reversed (forward wired as reverse)

② Star-delta start timer delay set incorrectly

③ Star / delta wiring error

[Diagnostic Method]

① Jog to observe rotation direction

② Check star-delta transition time (typically 5~15s by motor power)

[Corrective Measures]

① Swap any two phase wires

② Adjust the star-delta transition time

③ Wire correctly per the nameplate

VFD Overcurrent Fault

[Phenomenon]

The VFD reports an overcurrent alarm (OC/SC) and the motor stops.

[Possible Causes]

① Acceleration time set too short

② Motor or cable short / ground fault

③ Motor rated parameters set incorrectly

④ Sudden load change (e.g., mechanical jam)

[Diagnostic Method]

① Check the VFD fault record code

② Run the motor disconnected at no load to determine whether the fault is the VFD or the motor

③ Check motor insulation

[Corrective Measures]

① Extend acceleration time

② Check motor insulation and cable

③ Re-enter the motor nameplate parameters

④ Check the mechanical load

Stepper Motor Step Loss Under Load

[Phenomenon]

Runs normally unloaded; position drifts once load is applied.

[Possible Causes]

① Motor torque insufficient for the load (torque-speed curve drops)

② Acceleration time too short

③ Driver current setting too low

④ Drive voltage too low

⑤ Load-to-inertia ratio too high

[Diagnostic Method]

① Run at low speed to check for step loss (more torque available at low speed)

② Measure the driver supply voltage

③ Check the driver current setting

[Corrective Measures]

① Lower the operating speed or use a larger motor

② Extend accel/decel time (≥0.3s)

③ Raise the driver current to the motor rated

④ Increase supply voltage (recommend DC36~48V)

⑤ Increase the reduction ratio

Servo Motor Overload Alarm

[Phenomenon]

During operation the servo drive reports an overload alarm (e.g., AL.051 / Err21).

[Cause Analysis]

① Acceleration/deceleration time too short → acceleration torque too high

② Load-to-inertia ratio out of spec → motor must overcome excessive inertia

③ Mechanical jam / stall → load abnormally high

④ Braking resistor undersized → energy cannot be dissipated during deceleration

⑤ Undersized motor → actual torque exceeds rated

⑥ Encoder signal interference → abnormal feedback

[Diagnostic Steps]

① Check the drive alarm code

② Check whether the actual torque monitor value exceeds rated

③ Check whether the inertia-ratio setting is within the recommended range

④ Manually turn the shaft to check mechanical resistance

⑤ Measure the braking resistor resistance

[Countermeasures]

① Extend acceleration/deceleration time

② Increase the reduction ratio to lower the inertia ratio

③ Check mechanical lubrication and assembly

④ Use a larger motor

⑤ Replace the braking resistor

[Related Modules] FT_12_Systematic Motor Selection, FT_13_Reducer-Motor Matching Selection

Motor Bearing Abnormal Noise Diagnosis

[Symptoms] The bearing emits abnormal sound during motor operation.

[Diagnosis]

① Metallic friction sound — poor lubrication

② Clicking sound — cage damage

③ Humming sound — insufficient clearance

④ Irregular sound — rolling-element damage

[Countermeasures]

① Replenish grease

② Replace the bearing

③ Select appropriate clearance

④ Check bearing installation

Stepper Motor Step Loss

[Symptoms] The stepper motor loses pulses during operation, causing inaccurate positioning.

[Cause]

① Acceleration time too short

② Load torque exceeds motor torque

③ Insufficient drive voltage

④ Motor speed near the resonance region

⑤ Inertia ratio too high

[Countermeasures]

① Extend acceleration/deceleration time

② Check the torque-speed curve

③ Raise the driver voltage

④ Avoid the resonance frequency

⑤ Increase the reduction ratio

Motor Overtemperature

[Symptoms] Motor surface temperature exceeds the allowable value.

[Cause]

① Overload (exceeds rated)

② Poor heat dissipation (fan fault / duct blockage)

③ Ambient temperature too high

④ Unbalanced or low voltage

⑤ Frequent start/stop

[Countermeasures]

① Reduce load or use a larger motor

② Clear the duct and check the fan

③ Improve ventilation

④ Check the supply voltage

⑤ Extend run/stop time