Weld metal cracks along grain boundaries at high temperature, with a zigzag path and an oxidized surface.
① Base metal S / P impurities too high
② Weld depth-to-width ratio too large
③ Cooling rate too fast
④ Improper arc termination; crater not filled
① Check base metal and filler S / P content, should be ≤0.04%
② Observe crack morphology (longitudinal / transverse / crater)
③ Use magnetic particle or dye penetrant testing to determine the crack extent
① Control S / P content in the base metal and filler
② Adjust the groove shape to increase the width-to-depth ratio
③ Preheat 100~150℃ before welding
④ Use current ramp-down or back-burn to fill the crater at arc termination
Cracks appear delayed, from hours to days after welding; no oxidation color; intergranular or transgranular.
① High diffusible hydrogen in the weld
② Hardened microstructure in the heat-affected zone
③ High restraint stress in the joint
④ No preheat or insufficient preheat before welding
① Use ultrasonic testing to detect internal cracks
② Measure heat-affected zone hardness (should be ≤HV350)
③ Check the preheat temperature records
① Use low-hydrogen electrodes and dry them strictly (350℃×1h)
② Preheat before welding (by plate thickness: below 20mm 100℃, 20~40mm 150℃)
③ Hydrogen-removal treatment immediately after welding (250~350℃×2h)
④ Keep weld hydrogen content ≤5ml/100g
Round or oval pores appear on or inside the weld, either isolated or densely distributed.
① Shielding gas flow too low (<15L/min) or too high, blowing the shielding away
② Oil, rust, or moisture on the filler wire or base metal surface
(3) Excessive air flow (wind speed > 2 m/s)
④ Insufficient gas purity (CO₂ purity <99.5%)
① Visually inspect pore morphology (round pores with smooth inner walls)
② Take X-ray films to determine pore location and size
③ Check the shielding gas flow meter
① Clean oil and rust from within 20mm on both sides of the groove before welding
② Adjust shielding gas flow (15~25L/min)
③ Set up wind screens
④ Switch to higher-purity gas
⑤ Dry the electrodes strictly
The weld fails to fuse completely with the base metal or between passes, appearing as strips or patches.
① Welding current too low
② Welding speed too fast
③ Groove angle too small
④ Improper torch angle (not aimed at the fusion face)
① Macro metallographic examination of the cross-section
② Ultrasonic testing for lack of fusion
③ Verify the welding procedure parameters
① Increase welding current appropriately (10~20%)
② Reduce welding speed
③ Increase the groove angle (60°~70°)
④ Adjust the torch angle (10°~15° push angle)
The weld root is not fully penetrated, leaving a gap at the root.
① Root face too large (>2mm)
② Root gap too small (<2mm)
③ Welding current too low
④ Back side not gouged before welding the second side
① Visually inspect the root
② Use radiographic testing to determine the penetration depth
③ Measure the groove dimensions
① Keep the root face at 1~2mm
② Root gap ≥2mm
③ Increase welding current
④ Gouge the back side by carbon arc air gouging before welding the second side
The base metal at the weld toe is melted into a groove and not filled with metal.
① Welding current too high
② Welding speed too fast
③ Wire stick-out too long
④ Improper torch angle
① Visually inspect the weld toe
② Measure undercut depth and length
① Reduce welding current
② Slow the welding speed
③ Control wire stick-out (10~15mm)
④ Reduce weave width and increase dwell time at the edges
Molten metal flows onto unfused base metal and piles up into a beaded bump.
① Welding current too high
② Welding speed too slow
③ Wire stick-out too long
④ Unsteady manipulation
① Visually inspect the weld appearance
② Measure the overlap size
① Reduce welding current
② Increase welding speed appropriately
③ Control wire stick-out
④ Improve manipulation consistency
Excessive penetration causes the molten pool to collapse and form a hole.
① Welding current too high
② Welding speed too slow
③ Root gap too large
④ No backing when welding thin plate
① Visually inspect the burn-through location
② Measure the burn-through hole diameter
① Reduce welding current (use pulsed welding for thin plate)
② Increase welding speed
③ Reduce the root gap
④ Add a copper or ceramic backing
⑤ For plate thickness <3mm, use low-current CO₂ welding
The arc-termination point is not filled; star-shaped cracks form as it cools.
① Current cut off abruptly at arc termination
② Crater not filled
③ Material highly crack-sensitive
① Visually inspect the crater area
② Use dye penetrant testing to confirm the crack
① Use current ramp-down at arc termination
② Fill the crater (back-burn method)
③ Use a crater-fill plate
④ Grind the crater away after arc termination
The weld bead is uneven in height and width, with irregular toes.
① Unstable wire feed
② Uneven welding speed
③ Unsteady torch weaving
④ Mains voltage fluctuation
① Visually inspect the weld appearance
② Check the wire feed mechanism
① Check the feed roller pressure and the wire guide tube
② Steady the welding speed
③ Use a track or welding carriage
④ Add a voltage stabilizer
Causes:
① High S / P content in the weld metal
② Excessive welding stress
③ Improper weld shape factor (small width-to-depth ratio)
Preventive measures:
① Control S / P content in the base metal and filler
② Preheat to reduce the cooling rate
③ Select a reasonable groove shape
④ Use low-hydrogen electrodes
Causes:
① High diffusible hydrogen content
② Hardened microstructure (martensite)
③ High restraint stress
Preventive measures:
① Preheat before welding (per plate thickness and material)
② Slow cooling or post-heating after welding
③ Use low-hydrogen electrodes and dry them
④ Hydrogen-removal treatment immediately after welding
Causes:
① Narrow, deep weld
② Crater not filled
Preventive measures:
① Increase the groove angle
② Fill the crater
③ Use current ramp-down at arc termination
Other quick references in this series:Hydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisMechanical component faultsBearing faultsGear faultsHydraulic / pneumatic valves