Common Faults · Mechanical Component Faults (Quick-Reference Handbook)

Bearing overheating (> 80°C)

[Bearing overheating (> 80°C)]

[Phenomenon] Bearing-housing temperature abnormally high, hot to touch

[Possible Causes]

(1) Too much or too little grease; (2) Too-small bearing clearance (over-preload); (3) Excessive seal friction; (4) Too-tight inner/outer fit; (5) Poor shaft alignment

[Diagnostic Method]

(1) Infrared thermometer to measure bearing-housing points; (2) Listen (sharp / hiss); (3) Measure vibration

[Corrective Measures]

(1) Fill proper grease amount (1/3~1/2 cavity); (2) Use proper-clearance bearing (C3 / CM); (3) Check seal contact; (4) Check fit tolerance (inner k6/m6 / outer J7); (5) Re-align

Bearing abnormal noise (sharp)

[Bearing abnormal noise (sharp)]

[Phenomenon] Bearing emits sharp metallic squeak during operation

[Possible Causes]

(1) Poor lubrication (dry friction); (2) Too-small bearing clearance; (3) Too-high speed / unsuitable grease; (4) Excessive installation preload

[Diagnostic Method]

(1) Listen (sharp / squeak / click); (2) Stethoscope to locate sound source

[Corrective Measures]

(1) Add / replace grease (high-speed grease for high speed); (2) Check clearance (select C3); (3) Lower speed or use high-speed bearing; (4) Reduce preload

Bearing abnormal noise (dull)

[Bearing abnormal noise (dull)]

[Phenomenon] Bearing emits dull hum during operation

[Possible Causes]

(1) Raceway pitting / spalling (fatigue); (2) Roller breakage (cylindrical roller bearing); (3) Cage wear / breakage

[Diagnostic Method]

(1) Listen (varies with speed); (2) Measure vibration (acceleration spectrum shows clear fault frequency); (3) Disassemble bearing

[Corrective Measures]

(1) Replace bearing (pitting irreversible); (2) Check lubrication & seal (prevent ingress); (3) Replace cage; (4) Check shaft & housing fit

Bearing abnormal noise (irregular)

[Bearing abnormal noise (irregular)]

[Phenomenon] Bearing emits irregular clicking during operation

[Possible Causes]

(1) Foreign object ingress (iron chip / sand); (2) Raceway indentation (impact load); (3) Internal rust; (4) Grease contains impurities

[Diagnostic Method]

(1) Irregular / intermittent sound; (2) Take grease to check (particles); (3) Disassemble raceway surface

[Corrective Measures]

(1) Replace bearing + check seal (lip intact); (2) Replace grease (clean before adding); (3) Check work environment (waterproof / dustproof); (4) Add guard if needed

Bearing high vibration

[Bearing high vibration]

[Phenomenon] Bearing-housing vibration > 5 mm/s

[Possible Causes]

(1) Bearing wear (clearance grows); (2) Raceway spalling / pitting; (3) Journal oval / housing bore deformed; (4) Rotor dynamic imbalance

[Diagnostic Method]

(1) Measure vibration (accelerometer / vib pen); (2) Spectrum analysis (identify fault freq); (3) Rock shaft after stop (feel clearance)

[Corrective Measures]

(1) Replace bearing; (2) Repair / replace journal (re-round); (3) Repair housing bore (bore); (4) Rotor dynamic balance

Bearing outer-ring slip

[Bearing outer-ring slip]

[Phenomenon] Outer ring rotates in housing bore (loose fit)

[Possible Causes]

(1) Outer ring / housing bore fit too loose (clearance fit); (2) Housing bore worn (oval / enlarged); (3) Housing deformation

[Diagnostic Method]

(1) Check bore roundness & size; (2) Apply prussian blue to outer ring, test contact marks

[Corrective Measures]

(1) Apply bearing retainer / nickel-plate repair to bore; (2) Bore sleeve (steel); (3) Replace housing; (4) Use outer-ring tolerance J7/K7 (interference)

Bearing inner-ring slip

[Bearing inner-ring slip]

[Phenomenon] Inner ring rotates on shaft (loose fit)

[Possible Causes]

(1) Inner ring / shaft fit too loose; (2) Journal worn (smaller / oval); (3) Large start-up impact (insufficient cold-start interference)

[Diagnostic Method]

(1) Check journal size & roundness; (2) Check inner-ring axial fixation looseness

[Corrective Measures]

(1) Journal knurling / chrome-plating / brush-plating repair; (2) Use fit k6/m6 (interference); (3) Lock nut with anti-loosening

Bearing cage break

[Bearing cage break]

[Phenomenon] Metallic impact sound then seizure during operation

[Possible Causes]

(1) Poor cage material / manufacturing defect; (2) Large vibration impact; (3) Poor lubrication (cage guide surface wear); (4) Improper installation (tilt)

[Diagnostic Method]

(1) Disassemble bearing (cage fragments); (2) Check lubrication state

[Corrective Measures]

(1) Replace bearing (check lubrication after restore); (2) Check alignment & installation; (3) Use brass cage (more impact-resistant than steel); (4) Ensure adequate lubrication

Bearing seal failure

[Bearing seal failure]

[Phenomenon] Grease leakage / external ingress at bearing

[Possible Causes]

(1) Seal lip wear (rubbing shaft); (2) Seal spring fatigue (insufficient pressure); (3) Shaft surface rough / scratched, damages seal; (4) Seal / shaft eccentricity

[Diagnostic Method]

(1) Visually check grease leak / foreign color; (2) Disassemble seal lip

[Corrective Measures]

(1) Replace seal (radial oil seal); (2) Check shaft surface Ra ≤ 0.8 μm; (3) Shaft-end chamfer (seal install); (4) Add dust cap to seal

Bearing rust

[Bearing rust]

[Phenomenon] Rust spots on raceway / roller surface

[Possible Causes]

(1) Seal failure (water ingress); (2) High ambient humidity; (3) Grease contains water / acid; (4) Long idle (condensate)

[Diagnostic Method]

(1) Visually check rust location & degree; (2) Take grease to measure water content

[Corrective Measures]

(1) Replace bearing; (2) Improve seal (labyrinth / double lip); (3) Dehumidify environment; (4) Rotate shaft periodically / add rust-proof grease during long idle

Bearing electric erosion

[Bearing electric erosion]

[Phenomenon] Corrugated pits (discharge marks) on raceway surface

[Possible Causes]

(1) Motor shaft current through bearing → housing → ground (spark); (2) Inverter PWM induced voltage; (3) Welding current through bearing

[Diagnostic Method]

(1) Visually check (corrugated / washboard pits on raceway); (2) Measure shaft voltage (oscilloscope, shaft-to-ground)

[Corrective Measures]

(1) Add insulated bearing (N series) at non-drive end; (2) Add grounding carbon brush at drive end; (3) Add EMC filter to inverter output; (4) Keep ground cable near workpiece when welding

Bearing wears too fast

[Bearing wears too fast]

[Phenomenon] New bearing shows obvious clearance in < 1000 h

[Possible Causes]

(1) Poor lubrication (no oil / wrong oil); (2) Foreign ingress (dust / abrasive); (3) Improper install (alignment / preload); (4) Wrong selection (load / speed mismatch)

[Diagnostic Method]

(1) Measure radial clearance (vs new); (2) Check grease contamination; (3) Check install alignment

[Corrective Measures]

(1) Improve lubrication (oil mist / grease amount); (2) Strengthen seal (dustproof / waterproof); (3) Re-install (proper align / preload); (4) Re-select (larger or different material)

Gear noise large

[Gear noise large]

[Phenomenon] Gearbox noise > 85 dB(A)

[Possible Causes]

(1) Low gear accuracy (below grade 7); (2) Tooth surface wear / pitting; (3) Gear imbalance; (4) Bearing wear; (5) Housing resonance

[Diagnostic Method]

(1) Sound level meter for noise (separate mesh frequency); (2) Contact-patch check (red lead); (3) Gearbox vibration spectrum analysis

[Corrective Measures]

(1) Raise gear accuracy (grade 6); (2) Modify tooth profile (tip relief); (3) Gear dynamic balance; (4) Replace bearing; (5) Add ribs / damping to housing

Gear tooth-surface wear

[Gear tooth-surface wear]

[Phenomenon] Obvious wear near working pitch line

[Possible Causes]

(1) Poor lubrication (oil / amount insufficient); (2) Low tooth-surface hardness; (3) Hard particles ingress (abrasive wear); (4) Long-term overload

[Diagnostic Method]

(1) Visually check wear (near pitch circle); (2) Measure tooth thickness (vs original); (3) Oil sample analysis (iron content)

[Corrective Measures]

(1) Replace lube oil (add suitable EP agent); (2) Raise tooth-surface hardness (carburizing & quenching HRC 58~62); (3) Improve seal / filter; (4) Reduce load / change material

Gear scoring (scuffing)

[Gear scoring (scuffing)]

[Phenomenon] Tearing / welding marks along sliding direction on tooth surface

[Possible Causes]

(1) High tooth pressure + high sliding speed → oil film rupture; (2) High oil temperature (> 80°C) → viscosity drops; (3) Too-rough tooth surface (> Ra0.8)

[Diagnostic Method]

(1) Visually check (tearing / grooves on surface); (2) Check tooth-surface hardness

[Corrective Measures]

(1) Use high-viscosity lube or synthetic oil (PAO); (2) Improve cooling (oil-jet lubrication); (3) Lower tooth-surface roughness (Ra ≤ 0.4); (4) Copper-plating / phosphating tooth surface

Gear tooth breakage

[Gear tooth breakage]

[Phenomenon] Complete fracture at tooth root

[Possible Causes]

(1) Severe overload (impact); (2) Tooth-root bending fatigue (long-term cycle); (3) Too-small root fillet (stress concentration); (4) Material defect / heat-treat crack

[Diagnostic Method]

(1) Visually check fracture (fatigue fracture has shell marks / overload fracture coarse); (2) Metallographic analysis of fracture; (3) Hardness check

[Corrective Measures]

(1) Prevent overload (add safety coupling); (2) Increase module or face width; (3) Enlarge root fillet (R ≥ 0.38 m); (4) Shot peening at root; (5) Use higher-strength material

Chain skipping

[Chain skipping]

[Phenomenon] Chain jumps / disengages on sprocket

[Possible Causes]

(1) Chain wear elongation (pitch grows); (2) Sprocket tooth wear; (3) Too-large center distance (large sag); (4) Sprocket misalignment

[Diagnostic Method]

(1) Check chain elongation (≥ 3% replace); (2) Check sprocket tooth form (hook tooth replace); (3) Check sprocket face parallelism

[Corrective Measures]

(1) Replace chain (don't mix old & new); (2) Replace worn sprocket; (3) Adjust center distance / tensioner; (4) Re-align sprocket

Belt slip

[Belt slip]

[Phenomenon] Belt slips on pulley (transmitted power drops)

[Possible Causes]

(1) Insufficient belt tension; (2) Belt wear (cover worn smooth); (3) Pulley groove worn (smooth); (4) Overload; (5) Belt oil / water

[Diagnostic Method]

(1) Check tension (deflection method); (2) Flip belt (check inner side smooth); (3) Check pulley groove

[Corrective Measures]

(1) Re-tension (hand-press deflection ≈ 15 mm / 100 mm center distance); (2) Replace belt; (3) Replace pulley; (4) Reduce load or larger belt type; (5) Keep belt dry

Coupling damage

[Coupling damage]

[Phenomenon] Coupling elastomer rupture / diaphragm crack

[Possible Causes]

(1) Poor shaft alignment (concentricity > 0.1 mm); (2) Over-torque load (impact); (3) Undersized coupling; (4) Elastomer aging (normal 1~2 years)

[Diagnostic Method]

(1) Check centering (dial indicator); (2) Check elastomer (crack / powdering / deformation); (3) Calculate actual transmitted torque

[Corrective Measures]

(1) Re-align (laser aligner / dial indicator concentricity < 0.05 mm); (2) Replace elastomer (polyurethane / Hytrel); (3) Use larger coupling; (4) Periodic replacement (annual maintenance)

Key connection damage

[Key connection damage]

[Phenomenon] Keyway rounded / key deformed / key sheared

[Possible Causes]

(1) Undersized key (torque exceeds key capacity); (2) Keyway machined off-center (uneven load); (3) Overload (impact); (4) Key / keyway fit too loose

[Diagnostic Method]

(1) Check key & keyway (rounded / deformed / sheared); (2) Measure actual transmitted torque

[Corrective Measures]

(1) Size key by torque (per GB/T 1096); (2) Ensure keyway symmetry ≤ 0.02 mm; (3) Prevent overload (add shear pin); (4) Key / keyway fit (P9/h9)

Spline wear

[Spline wear]

[Phenomenon] Spline tooth-side wear / large clearance

[Possible Causes]

(1) Poor lubrication; (2) Low tooth-surface hardness (not quenched); (3) Misalignment (spline shaft & hole not coaxial); (4) Long-term heavy load (impact)

[Diagnostic Method]

(1) Visually check spline tooth side (wear marks); (2) Measure clearance (vs new)

[Corrective Measures]

(1) Improve lubrication (grease fill); (2) Spline surface quenching (HRC 48~55); (3) Ensure axis alignment; (4) Use involute spline (better than rectangular)

Guideway wear

[Guideway wear]

[Phenomenon] Linear-guide slider resistance increases / accuracy drops

[Possible Causes]

(1) Insufficient lubrication (grease dried); (2) Poor guide protection (iron chips ingress); (3) Mounting base deformation (accuracy lost); (4) Excessive preload

[Diagnostic Method]

(1) Check guide surface (scratch / rust); (2) Measure slider resistance (friction); (3) Check lubrication state

[Corrective Measures]

(1) Clean guide / replenish grease; (2) Add guard (accordion / roll); (3) Correct base / re-install; (4) Adjust preload (lower one grade)

Screw wear

[Screw wear]

[Phenomenon] Ball-screw nut clearance grows / positioning accuracy drops

[Possible Causes]

(1) Poor lubrication (no oil / bad oil); (2) Seal failure (dust ingress); (3) Natural wear from long use; (4) Misalignment

[Diagnostic Method]

(1) Measure backlash (dial indicator); (2) Measure screw axial play; (3) Check screw surface

[Corrective Measures]

(1) Replenish / replace grease (lithium); (2) Replace screw seal (wiper); (3) Adjust preload (double-nut backlash elimination); (4) Re-correct installation

Screw bend

[Screw bend]

[Phenomenon] Ball-screw radial runout exceeds limit (> 0.05 mm)

[Possible Causes]

(1) Poor install alignment (after long operation); (2) Excessive radial load (belt tension / gear radial force); (3) Accidental collision

[Diagnostic Method]

(1) Support between centers, measure radial runout (dial indicator); (2) Check mounting base level

[Corrective Measures]

(1) Straighten screw (straightener / press); (2) Correct alignment / reduce radial force (add coupling); (3) Replace screw (severe bend)

Hydraulic line rupture

[Hydraulic line rupture]

[Phenomenon] Hydraulic line (rigid / hose) suddenly bursts

[Possible Causes]

(1) System pressure too high (safety valve failed); (2) Line vibration fatigue (long term); (3) Line corroded / worn (external); (4) Hose aged (past service life)

[Diagnostic Method]

(1) Measure actual system pressure (vs set); (2) Check safety valve setting; (3) Check line appearance

[Corrective Measures]

(1) Repair safety valve (stuck); (2) Add line clamps to damp / use thicker pipe; (3) Add protective sleeve (anti-wear); (4) Periodic hose replacement (recommend 2 years)

Cylinder does not reach end

[Cylinder does not reach end]

[Phenomenon] Cylinder does not extend / retract fully

[Possible Causes]

(1) Low supply pressure (large load); (2) Foreign object / rust inside cylinder; (3) High piston-seal resistance; (4) Poor drainage (water in cylinder)

[Diagnostic Method]

(1) Measure cylinder inlet pressure; (2) Disassemble to check bore; (3) Check piston seal

[Corrective Measures]

(1) Raise supply pressure (≤ 0.7 MPa); (2) Clean bore (derust) + lubricate; (3) Replace piston seal; (4) Add dryer to remove water

Pneumatic system pressure drops fast

[Pneumatic system pressure drops fast]

[Phenomenon] System pressure drops rapidly after stop (poor holding)

[Possible Causes]

(1) Leak point in line (fitting / valve / cylinder); (2) End drain valve not closed; (3) Relief valve internal leak; (4) Filter drain valve loose

[Diagnostic Method]

(1) Close valves section by section to test; (2) Listen for leak / soapy water

[Corrective Measures]

(1) Find & fix leak (most effective energy-saving); (2) Close drain valve tight / replace auto drain; (3) Replace relief valve / seal; (4) Tighten filter drain valve

Seal extrusion / damage

[Seal extrusion / damage]

[Phenomenon] O-ring / oil seal extruded & damaged from groove

[Possible Causes]

(1) Seal gap too large (too-loose fit); (2) Pressure too high (> seal allowable); (3) Low O-ring hardness; (4) Sharp groove edge (scratch)

[Diagnostic Method]

(1) Check seal groove clearance; (2) Measure system pressure

[Corrective Measures]

(1) Reduce seal gap (≤ 0.2 mm); (2) Use back-up ring (prevent extrusion); (3) Raise O-ring hardness (HS 80~90); (4) Chamfer / deburr groove edge

Lubrication system fault (no oil)

[Lubrication system fault (no oil)]

[Phenomenon] Centralized lubrication system does not supply oil to lube points

[Possible Causes]

(1) Lube pump fault (motor burned / plunger stuck); (2) Tank low on oil; (3) Distributor blocked / drive failed; (4) Line blocked / burst

[Diagnostic Method]

(1) Check pump operation (pressure / sound); (2) Check tank oil level; (3) Check distributor indicator rod

[Corrective Measures]

(1) Repair / replace lube pump; (2) Top up oil (proper viscosity by season); (3) Clean distributor (impurities); (4) Blow / replace line

Vibration isolator failure

[Vibration isolator failure]

[Phenomenon] Equipment vibration transmits to foundation through isolator

[Possible Causes]

(1) Isolator aging (rubber cracking / hardening); (2) Isolator compression too large (near bottoming); (3) Wrong isolator selection (natural frequency mismatch); (4) Installation tilt

[Diagnostic Method]

(1) Check isolator appearance (cracking / deformation); (2) Measure isolator vibration transfer ratio (top vs bottom)

[Corrective Measures]

(1) Replace isolator (recommend cycle 5 years); (2) Adjust compression (proper static deflection); (3) Re-select (by disturbance freq); (4) Adjust installation position

Other related quick references:Welding defectsHydraulic systemPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisBearing faultsGear faultsHydraulic / pneumatic valves