MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

On this page

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Common Faults › Hydraulic System

Common Faults · Hydraulic System (Quick Reference Manual)

Hydraulic System Pump Cavitation Noise

[Phenomenon]

The pump emits a sharp squeal and the tank shows aerated returning oil.

[Possible Causes]

① Suction filter clogged (vacuum >0.03MPa)

② Tank oil level too low (below the minimum)

③ Suction line too small (velocity >1.5m/s)

④ Oil viscosity too high (low ambient temperature)

⑤ Suction-line joint air leak

[Diagnostic Method]

① Install a vacuum gauge at the pump suction (normal <0.02MPa)

② Check the tank level gauge

③ Check oil temperature (should be 30~55℃)

[Corrective Measures]

① Clean or replace the suction filter (rating 100~150μm)

② Top up oil to the maximum level

③ In winter, switch to low-viscosity hydraulic oil (VG 32 or 46)

④ Tighten suction-line joints and replace seals

Hydraulic System Pump Insufficient Flow

[Phenomenon]

Actuator speed drops noticeably and system pressure builds up slowly.

[Possible Causes]

① Pump volumetric efficiency down (wear and high internal leakage)

② High suction resistance (clogged filter / viscous oil)

③ Variable-displacement pump control mechanism fault

④ Pump speed too low

[Diagnostic Method]

① Measure flow at the pump outlet (compare with rated value)

② Measure pump case drain flow (to gauge internal leakage)

③ Check the prime mover speed

[Corrective Measures]

① Replace the worn pump

② Clean the filter

③ Inspect and adjust the displacement control mechanism

④ Ensure prime mover speed reaches the rated value

Hydraulic System Pump Low Pressure

[Phenomenon]

System pressure fails to reach the set value or fluctuates with load.

[Possible Causes]

① Relief valve pressure spring fatigued or broken

② Relief valve spool stuck in the open position

③ Severe internal leakage in the pump

④ Heavy leakage at pipe joints

⑤ Damaged cylinder / motor seals

[Diagnostic Method]

① Fit a pressure gauge at the pump outlet to measure supply pressure

② Fully close the relief valve, then slowly adjust it to the set value

③ If outlet pressure is normal → valve or actuator problem

④ If outlet pressure is low → pump or suction problem

[Corrective Measures]

① Clean / replace the relief valve spool and spring

② Repair or replace the pump

③ Tighten pipe joints

④ Replace damaged seals

Hydraulic System Cylinder Stick-Slip

[Phenomenon]

At low speed the cylinder moves in a jerky, stop-and-lurch manner.

[Possible Causes]

① Air trapped in the cylinder; unstable back pressure in the return chamber

② Excessive piston seal friction (stick-slip effect)

③ Piston rod / cylinder barrel scored

④ Uneven guideway friction

(5) Supply pressure fluctuation

[Diagnostic Method]

① Bleed at the highest point of the cylinder (open the bleed valve until oil flows bubble-free)

② Push the piston rod by hand to feel the resistance

③ Check the piston rod surface for scoring

④ Lower the speed and observe whether stick-slip worsens

[Corrective Measures]

① Bleed through several full strokes

② Fit low-friction seals (e.g. PTFE + bronze-filled composite seals)

③ Hone / lap the scored surface to restore it

④ Lubricate the guideways

(5) Add accumulator to stabilize pressure

Hydraulic System High Oil Temperature

[Phenomenon]

Tank temperature exceeds 60℃; the oil thins and system efficiency drops.

[Possible Causes]

① Tank volume too small (<3× system flow)

② Cooler clogged or fan not running

③ Relief valve set pressure too high

④ Excessive line pressure loss (pipe too small / too many elbows)

⑤ Oil viscosity too high

[Diagnostic Method]

① Measure tank temperature (normal 30~55℃, warning 55~60℃, danger >60℃)

② Check the cooler oil temperature difference in/out (should be ≥5℃)

③ Measure the pressure drop across each line section

[Corrective Measures]

① Enlarge the tank or add a cooler

② Clean the cooler fins and check the fan

③ Lower the relief valve set pressure to a reasonable value

④ Increase pipe diameter and reduce elbows

⑤ Switch to hydraulic oil of suitable viscosity

Hydraulic System Pressure Surge/Vibration

[Phenomenon]

Severe shock and line vibration occur during reversing or stopping.

[Possible Causes]

① Directional valve shifts too fast

② Cylinder cushioning not working

③ Air not fully bled from the lines

④ Relief valve response lag

⑤ Lines not secured with pipe clamps

[Diagnostic Method]

① Observe when the shock occurs (reversing / stopping / loading)

② Check the cylinder cushion adjusting screw

③ Check the amplitude of line vibration

[Corrective Measures]

① Add a solenoid soft-shift module to the directional valve

② Adjust the cylinder cushion throttle valve

③ Bleed the system

④ Install an accumulator near the shock source

⑤ Add pipe clamps (spacing 1~1.5m)

Hydraulic System Cylinder Creep

[Phenomenon]

A vertically mounted cylinder drifts down slowly after oil supply stops.

[Possible Causes]

① Pilot-operated check valve leaking

② Cylinder piston seal leakage

③ Internal leakage in the directional valve

④ High oil temperature accelerates internal leakage

[Diagnostic Method]

① Fit a pressure gauge at the pilot check valve outlet for a hold test

② Isolate each component in turn to locate the leakage source

[Corrective Measures]

① Replace the pilot check valve spool

② Replace the piston seal

③ Replace the directional valve spool

④ Add a pressure-holding accumulator

Hydraulic System Emulsified (Milky) Oil

[Phenomenon]

The oil turns milky and opaque, indicating water in the oil.

[Possible Causes]

① Ruptured cooler (water-cooled)

② Tank cover poorly sealed, letting water in

③ New oil itself over the water-content limit

④ High ambient humidity; the tank breather draws in moisture

[Diagnostic Method]

① Take an oil sample to test water content (normal <500ppm)

② Check the cooler water outlet for oil sheen

③ Check the tank top cover seal

[Corrective Measures]

① Repair or replace the cooler

② Improve the tank seal and add a desiccant breather

③ Change the oil completely and flush the system

④ Take oil samples regularly to test water content

Hydraulic System Pump Shaft Seal Oil Leak

[Phenomenon]

Oil leaks out at the pump shaft seal.

[Possible Causes]

① Shaft seal aged and worn

② Excessive pump case pressure (restricted drain)

③ High oil temperature accelerates seal aging

④ Shaft surface rough or scratched

⑤ Oil incompatible with the seal material

[Diagnostic Method]

① Check whether the pump case drain port is clogged

② Check the oil temperature

③ Observe the leak rate to judge the extent of seal damage

[Corrective Measures]

① Replace the shaft seal (note the orientation, lip facing into the pump)

② Clear the case drain line (ID ≥10mm) to ensure free return flow

③ Keep oil temperature ≤60℃

④ If the shaft surface is scratched, repair or replace it

Hydraulic System Multi-Cylinder Synchronization Loss

[Phenomenon]

When several cylinders move at the same time, their speeds are inconsistent.

[Possible Causes]

① Unequal load on each cylinder

② Different friction in each cylinder

③ Unequal line lengths causing different pressure drops

④ Insufficient accuracy of the flow divider/combiner valve

[Diagnostic Method]

① Measure each cylinder's speed individually

② Check whether the lines to each cylinder are equal in length

③ Check the flow divider/combiner valve accuracy

[Corrective Measures]

① Add a flow divider/combiner valve (accuracy ±3~5%)

② Add a throttle valve at each cylinder inlet for individual speed control

③ Use proportional valves + closed-loop control

④ Keep the lines to all cylinders the same length

Hydraulic System Insufficient Pressure

[Phenomenon]

System pressure fails to reach the set value or drops markedly under load.

[Possible Causes]

① Relief valve spring fatigued / broken / spool stuck open

② Pump badly worn (volumetric efficiency <80%)

③ Cylinder piston seal damaged (high internal leakage)

④ Severe internal leakage in hydraulic valves

⑤ Heavy external leakage from the lines

[Diagnostic Method]

① Fit a pressure gauge at the pump outlet to measure supply pressure

② Fully close the relief valve, then slowly adjust it to the set value

③ If pump outlet pressure is normal but system pressure is low → valve / cylinder problem

④ If outlet pressure is low → pump or suction problem

[Corrective Measures]

① Clean or replace the relief valve spool and spring

② Repair or replace the pump

③ Replace the piston seal

④ Replace damaged hydraulic valves

⑤ Tighten pipe joints

Hydraulic System Pump Excessive Noise

[Phenomenon]

The pump emits a sharp squealing sound and the tank shows bubbles.

[Possible Causes]

① Suction filter clogged (vacuum >0.03MPa)

② Tank oil level too low

③ Suction line too small (velocity >1.5m/s)

④ Oil viscosity too high

⑤ Suction-line joint air leak

[Diagnostic Method]

① Install a vacuum gauge at the pump suction to measure vacuum

② Check the tank oil level

③ Check the oil temperature

[Corrective Measures]

① Clean or replace the suction filter

② Top up oil to the maximum level

③ In winter, switch to low-viscosity hydraulic oil

④ Tighten pipe joints and replace seals

Hydraulic System Pump Shaft End Oil Leak

[Phenomenon]

Oil leaks out at the pump shaft seal.

[Possible Causes]

① Shaft seal aged and worn

② Excessive pump case pressure (restricted drain)

③ Shaft surface scratched

④ Oil incompatible with the seal material

[Diagnostic Method]

① Check whether the pump case drain port is clogged

② Check the oil temperature

③ Observe the leak rate

[Corrective Measures]

① Replace the shaft seal (lip facing into the pump)

② Clear the case drain line (ID ≥10mm)

③ Repair or replace the pump shaft

④ Check oil compatibility

Hydraulic System Leakage

[Phenomenon]

Oil leaks at pipe joints / valve blocks / cylinders.

[Possible Causes]

① O-ring aged / worn / extruded

② Pipe joint not tightened

③ Scratched sealing surface

④ Pressure shock loosening the joint

[Diagnostic Method]

① Visually inspect for leak points

② Check O-ring condition

③ Check sealing faces for scratches

[Corrective Measures]

① Replace the O-ring (note material and size)

② Tighten pipe joints to the specified torque

③ Repair sealing surface

④ Eliminate pressure shock

Hydraulic System Cylinder Cushioning Failure

[Phenomenon]

The piston strikes the end cap at the end of its stroke.

[Possible Causes]

① Cushion throttle valve improperly adjusted

② Cushion plunger / sleeve worn

③ Cushion check valve stuck

④ Excessive load inertia

[Diagnostic Method]

① Adjust the cushion screw and observe the effect

② Check the cushion plunger clearance

[Corrective Measures]

① Re-adjust the cushion throttle valve

② Replace the cushion plunger or sleeve

③ Clean the cushion check valve

④ Fit an external hydraulic shock absorber

Hydraulic System Directional Valve Not Shifting

[Phenomenon]

The solenoid valve spool does not move when energized.

[Possible Causes]

① Solenoid burned out (abnormal coil resistance)

② Spool stuck (contamination / burrs)

③ Spring broken

④ Control voltage too low (<85% of rated)

[Diagnostic Method]

① Measure coil resistance with a multimeter

② Push the spool by hand to check freedom of movement

③ Energize and listen for the solenoid's pull-in sound

[Corrective Measures]

① Replace the solenoid

② Disassemble and clean the spool

③ Replace the spring

④ Ensure the supply voltage is normal

Hydraulic System Vibration and Noise

[Phenomenon]

Abnormal vibration and noise occur during system operation.

[Possible Causes]

① Pump cavitation (clogged filter / low oil level / air leak)

② Line resonance (pipe clamp spacing too wide)

③ Valve oscillation (relief valve / directional valve)

④ Air in the oil

[Diagnostic Method]

① Listen to the sound to locate the source (pump / valve / line)

② Check vacuum and oil level

③ Use a stethoscope to pinpoint it

[Corrective Measures]

① Clean the filter / top up oil / tighten pipe joints

② Add pipe clamps (spacing within 1m)

③ Clean or replace the faulty valve

④ Bleed the system

Hydraulic System Throttle Valve Unstable Speed Control

[Phenomenon]

A speed that was set correctly drifts after running for a while.

[Possible Causes]

① Oil temperature change altering viscosity

② Throttle orifice clogged (contamination)

③ Load variation

④ Pressure-reducing spool of the speed control valve sticking

[Diagnostic Method]

① Check for oil temperature variation

② Clean the throttle valve

③ Check load stability

[Corrective Measures]

① Switch to a speed control valve (with pressure compensation)

② Clean the throttle valve

③ Use proportional valve closed-loop control

Hydraulic System Insufficient Pressure: Fault Analysis

[Phenomenon]

The system cannot reach the set pressure, or the pressure fluctuates.

[Cause Analysis]

① Relief valve fault (spool stuck / spring broken / pressure setting loosened)

② Pump worn (volumetric efficiency down, high internal leakage)

③ Cylinder internal leakage (piston seal damaged)

④ Line leakage (loose joints / burst pipe)

⑤ Suction filter clogged → insufficient oil supply

⑥ Oil temperature too high → viscosity drops → internal leakage increases

[Diagnostic Steps]

① Check whether the oil level is normal

② Check whether the relief valve is adjusted correctly

③ Measure pressure at the pump outlet → determine whether the pump or the valve is at fault

④ Check oil temperature (normal 30~55℃)

⑤ Check the filter clogging indicator

⑥ Isolate each section in turn to check for leakage

[Countermeasures]

① Clean or replace the relief valve

② Replace the pump

③ Replace the seals

④ Tighten or replace the lines

⑤ Clean or replace the filter

⑥ Improve cooling or change the oil

Other quick references in this series:Welding defectsPneumatic systemMotor electricalEquipment faultsMotor faultsStructural part faultsSensor faultsElectrical faultsQuick diagnosisMechanical component faultsBearing faultsGear faultsHydraulic / pneumatic valves

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL