The cylinder does not move smoothly at low speed, showing intermittent pauses or jerking
① Poor lubrication (oil mist unit delivering less than 3 drops/min)
② Excessive piston seal friction
③ Piston rod misaligned during assembly
④ Supply pressure fluctuation
⑤ Exhaust silencer clogged
① Check the drip rate of the oil mist unit
② Push and pull the cylinder by hand to feel the friction
③ Check the coaxiality of the mounting
① Adjust the oil mist unit to 3~5 drops/min
② Replace with low-friction seals
③ Adjust the mounting position so the push rod axis coincides with the load axis
④ Add an air receiver tank to stabilize the pressure
⑤ Clean or replace the silencer
The valve spool does not move when the solenoid is energized, so the cylinder does not act
① Burned solenoid coil (infinite resistance / short circuit)
② Spool jammed by foreign matter
③ Pilot air passage blocked
④ Insufficient voltage (below 85% of the rated voltage)
⑤ Broken spring
① Measure the coil resistance with a multimeter (compare with the sample value)
② Listen for a "click" while energized
③ Manually push the spool to check that it moves freely
④ Measure the supply voltage
① Replace the solenoid valve coil
② Disassemble and clean the spool
③ Clear the pilot air passage (blow through to check)
④ Keep the supply voltage within the rated value ±10%
⑤ Replace the spring
The magnetic switch indicator does not light after the cylinder reaches its end position
① Magnetic switch mounting position offset
② Magnetic switch does not match the PLC input (NPN/PNP)
③ Demagnetization of the magnet ring on the piston
④ Signal line broken or loose contact
⑤ Insufficient load voltage
① Bring a magnet near the switch to check whether it triggers
② Check whether the indicator lamp lights
③ Measure the switch output voltage with a multimeter
① Adjust the magnetic switch position to the piston end position
② Replace with a switch of matching NPN/PNP type
③ Replace the cylinder piston assembly
④ Check the wiring and reconnect it
⑤ Ensure the load voltage is ≥DC21.6V
The cup cannot hold the workpiece stably, or the workpiece drops after being picked
① Insufficient vacuum (vacuum generator undersized)
② Cup worn or aged and cracked
③ Holes, oil contamination or a rough surface on the workpiece
④ Leak in the vacuum line
⑤ Workpiece too heavy / cup diameter too small
⑥ Vacuum breaker valve not fully closed
① Measure the vacuum at the cup with a vacuum gauge (should be ≥-60kPa)
② Check the cup surface for cracks
③ Check the sealing of every line fitting
① Use a larger vacuum generator or add a vacuum tank
② Replace the cup (check the material: NBR general purpose / silicone high temperature / polyurethane wear resistant)
③ Clean the workpiece surface
④ Inspect the line and replace aged tubing
⑤ Increase the cup diameter or add more cups
⑥ Safety factor ≥4 for horizontal holding, ≥8 for vertical
Excessive impact at the end of the cylinder stroke; the piston slams into the end cap
① Buffer needle valve adjusted too loose
② Buffer seal worn or damaged
③ Load inertia too large for the cushioning capacity
④ Cylinder speed too fast
① Close the buffer needle valve fully, then open it slowly
② Check the buffer seal
① Adjust the buffer needle valve (close it fully first, then open 1/4 turn and tune step by step)
② Replace the buffer seal
③ Add an external hydraulic buffer
④ Install a throttle valve to control the cylinder speed
Cracks or bursts appear in the pneumatic tubing shortly after it is put into service
① Bending radius too small (less than 6 times the tube outside diameter)
② Tube and fitting mismatch (large outside diameter tolerance)
③ Ambient temperature beyond the tubing temperature rating
④ Tubing aging (PU tubing life is about 2~3 years)
⑤ Line runs close to heat sources or moving parts
① Inspect the rupture location (bend / fitting / abrasion point)
② Measure the bending radius
③ Check the ambient temperature
① Keep the bending radius ≥6 times the tube outside diameter
② Use tubing and fittings of the same brand
③ In high-temperature environments use nylon or PTFE tubing
④ Replace the tubing at regular intervals (2~3 years)
⑤ Add protective sleeving and secure the line with tube clamps
Rust, water accumulation or seal swelling inside pneumatic components
① Refrigerant dryer failure (outlet dew point above 10℃)
② Automatic drain valve clogged and not draining
③ Pre-filter element saturated
④ Compressed air not cooled sufficiently
① Check the dryer outlet dew point (normal 2~10℃)
② Check whether the automatic drain valve operates
③ Check how long the filter element has been in service
① Repair the dryer (check the refrigeration compressor / condenser)
② Clean or replace the automatic drain valve
③ Replace the filter element (recommended every 3~6 months)
④ Add a downstream precision filter (0.01μm filtration)
System pressure falls more than 0.5MPa below the set value
① Air compressor output insufficient (reduced displacement / loose belt)
② Main pipeline diameter too small
③ Too many leak points in the system
④ Pressure regulator failure
⑤ Filter clogged, causing a large pressure drop
① Measure the pressure at the compressor outlet (should be 0.7~0.8MPa)
② Measure and compare the pressure at each branch
③ Stop production and watch the pressure decay rate to judge the leak volume
① Overhaul the compressor / replace the filter element
② Increase the main pipe diameter
③ Find and eliminate the leak points
④ Replace the pressure regulator
⑤ Clean or replace the filter
Pressure drops rapidly after the system is shut down, with a hissing sound
① Fitting not tightened / damaged O-ring
② Aging and rupture of the tubing
③ Leak at the cylinder end cap seal
④ Internal seal leak of the valve
⑤ Internal seal failure of the push-in fitting
① Locate by sound (listen for the leak)
② Soap bubble leak test
③ Stop production and watch the pressure decay rate
① Tighten the fitting or replace the O-ring
② Replace the tubing
③ Replace the cylinder end cap seal
④ Replace the valve
⑤ Replace the push-in fitting
Water collects in the tubing, components rust and seals swell
① Refrigerant dryer failure (dew point above 10℃)
② Automatic drain valve clogged
③ Filter element saturated
④ No drainage slope provided in the line
① Measure the dryer outlet dew point (normal 2~10℃)
② Check the automatic drain valve
③ Check the filter service life
① Repair the dryer
② Clean or replace the automatic drain valve
③ Replace the filter element
④ Provide a drainage slope in the line (≥1:100)
The cylinder cannot push the load, or it moves slowly
① Low supply pressure
② Cylinder bore size selected too small
③ Piston seal leakage
④ Piston rod binding (misaligned assembly)
⑤ Poor exhaust flow (silencer clogged)
① Measure the inlet pressure at the cylinder
② Push and pull by hand to check the friction
③ Check the alignment of the mounting
① Raise the supply pressure or enlarge the pipe diameter
② Fit a cylinder with a larger bore
③ Replace the piston seal
④ Adjust the mounting position
⑤ Clean or replace the silencer
The piston strikes the end cap, producing noise and vibration
① Buffer needle valve opened too far
② Buffer seal worn
③ Load inertia too large for the cushioning capacity
④ Cylinder speed too fast
① Close the buffer needle valve fully, then open it slowly and observe
② Check the buffer seal
① Adjust the buffer needle valve
② Replace the buffer seal
③ Add an external hydraulic buffer
④ Add a throttle valve to control the speed
At low speed the motion stops and starts intermittently
① Poor lubrication (oil mist unit delivering less than 3 drops/min)
② Large piston seal friction
③ Misaligned installation
④ Supply pressure fluctuation
⑤ Poor exhaust flow
① Check the drip rate of the oil mist unit
② Push and pull by hand to feel the resistance
③ Check the coaxiality of the mounting
① Adjust the oil mist unit to 3~5 drops/min
② Replace with low-friction seals
③ Adjust the installation
④ Add an air receiver tank to stabilize the pressure
⑤ Clean the silencer
The cup cannot hold the workpiece stably
① Insufficient vacuum (generator undersized / nozzle clogged)
② Cup worn or aged
③ Holes or oil on the workpiece surface
④ Leak in the line
⑤ Safety factor too small
① Measure the vacuum at the cup with a vacuum gauge (should be ≥-60kPa)
② Check the cup surface
③ Check the line
① Fit a larger vacuum generator or add a vacuum tank
② Replace the cup (NBR / silicone / polyurethane)
③ Clean the workpiece surface
④ Repair the leak points
⑤ Raise the safety factor (horizontal ≥4, vertical ≥8)
Cracks or bursts appear in the tubing
① Bending radius too small (less than 6 times the outside diameter)
② Tube and fitting mismatch
③ Ambient temperature out of range
④ Tubing aging (PU life 2~3 years)
⑤ External abrasion / impact
① Check the rupture location
② Check the bending radius
③ Measure the ambient temperature
① Keep the bending radius ≥6 times the outside diameter
② Use the same brand
③ In high temperatures use nylon or PTFE tubing
④ Replace at regular intervals
⑤ Add protective sleeving
The vacuum level does not reach the set value
① Nozzle clogged or worn
② Low supply pressure (<0.4MPa)
③ Leak in the vacuum line
④ Silencer clogged
① Check the nozzle
② Measure the supply pressure
③ Check the line sealing
① Clean or replace the nozzle
② Raise the supply pressure
③ Check and eliminate the leak points
④ Clean the silencer
The air compressor loads and unloads frequently, and the electricity cost is high
① Extensive leakage in the system
② Air supply not shut off when it is not in use
③ No individual shut-off valves on the branches
④ Unreasonable unloading pressure setting on the compressor
⑤ Small pipe diameter causing a large pressure drop
① Stop production and measure the leakage
② Check whether the line pressure is maintained after the shift ends
① Find and seal the leak points
② Close the main valve when air is not in use
③ Add a shut-off valve to each branch
④ Optimize the compressor start/stop pressure settings
⑤ Increase the pipe diameter
① Air compressor output insufficient / efficiency drop; ② Air leak in the line (fitting / damaged tubing); ③ Filter clogged (large pressure loss); ④ Pressure reducing valve set too low / faulty
① Observe the system pressure gauge; ② Close the downstream valve and measure the compressor outlet pressure; ③ Listen for air leaks in the line; ④ Check the filter differential pressure indicator
① Repair / replace the air compressor (select the size as needed); ② Find and seal the leaks (apply soapy water to the fittings); ③ Clean / replace the filter element (≤40μm); ④ Re-adjust / replace the pressure reducing valve
① Working pressure too low; ② Bore diameter too small (incorrect selection); ③ Worn piston seal causing internal leakage; ④ Load exceeds the rated output force of the cylinder
① Measure the air pressure at the cylinder inlet; ② Calculate the actual output force F=P×A; ③ Check the cylinder for air leaks (at the piston rod)
① Raise the system pressure to the set value (0.5~0.7MPa); ② Recalculate the load and select a larger bore; ③ Replace the piston seal; ④ Reduce the load or increase the bore
① Poor lubrication (no oil mist unit / insufficient oil); ② Piston seal too tight (uneven friction); ③ Inlet throttling too restrictive (insufficient supply); ④ Large resistance on the guideway / carriage
① Observe while running at low speed (10~50mm/s); ② Check the drip rate of the oil mist unit; ③ Check the opening of the inlet throttle valve
① Add an oil mist unit / increase the drip rate (1~3 drops/min); ② Replace the piston seal (hardness HS70±5); ③ Switch to exhaust throttling (inlet fully open); ④ Check the guideway lubrication
① Burned / jammed solenoid valve coil; ② Pilot air not supplied (double solenoid type); ③ Supply pressure below the minimum working pressure of the valve (0.15MPa); ④ Cylinder seized (rusted after long standstill)
① Listen for the solenoid valve operating sound (a click should be heard); ② Remove the coil and measure the resistance (compare with the nominal value); ③ Check whether there is air pressure in the pilot tube
① Replace the solenoid valve coil / spool; ② Check whether the pilot tube is supplying air; ③ Ensure the supply pressure is ≥0.15MPa; ④ Disassemble the cylinder and remove the rust / replace it
① Cushioning seal worn / damaged; ② Cushioning adjustment screw set too loose; ③ Cushioning needle valve clogged; ④ Excessive impact speed (large load inertia)
① Adjust the cushioning screw (clockwise increases the cushioning); ② Listen for air flow noise at the end of the stroke
① Replace the cushioning seal; ② Tighten the cushioning screw (adjust gradually); ③ Clean the cushioning needle valve; ④ Add an external hydraulic buffer
Related quick references: Welding DefectsHydraulic SystemsMotor ElectricalEquipment FaultsMotor FaultsStructural Part FaultsSensor FaultsElectrical FaultsQuick DiagnosisMechanical Component FaultsBearing FaultsGear FaultsHydraulic & Pneumatic Valves