Common Faults · Pneumatic Systems (Quick Reference)

Pneumatic System Cylinder Stuttering During Slow Travel

【Symptom】

The cylinder does not move smoothly at low speed, showing intermittent pauses or jerking

【Possible Causes】

① Poor lubrication (oil mist unit delivering less than 3 drops/min)

② Excessive piston seal friction

③ Piston rod misaligned during assembly

④ Supply pressure fluctuation

⑤ Exhaust silencer clogged

【Diagnostic Methods】

① Check the drip rate of the oil mist unit

② Push and pull the cylinder by hand to feel the friction

③ Check the coaxiality of the mounting

【Remedies】

① Adjust the oil mist unit to 3~5 drops/min

② Replace with low-friction seals

③ Adjust the mounting position so the push rod axis coincides with the load axis

④ Add an air receiver tank to stabilize the pressure

⑤ Clean or replace the silencer

Pneumatic System Solenoid Valve Fails to Switch

【Symptom】

The valve spool does not move when the solenoid is energized, so the cylinder does not act

【Possible Causes】

① Burned solenoid coil (infinite resistance / short circuit)

② Spool jammed by foreign matter

③ Pilot air passage blocked

④ Insufficient voltage (below 85% of the rated voltage)

⑤ Broken spring

【Diagnostic Methods】

① Measure the coil resistance with a multimeter (compare with the sample value)

② Listen for a "click" while energized

③ Manually push the spool to check that it moves freely

④ Measure the supply voltage

【Remedies】

① Replace the solenoid valve coil

② Disassemble and clean the spool

③ Clear the pilot air passage (blow through to check)

④ Keep the supply voltage within the rated value ±10%

⑤ Replace the spring

Pneumatic System Cylinder End-of-Stroke Signal Lamp Not Lit

【Symptom】

The magnetic switch indicator does not light after the cylinder reaches its end position

【Possible Causes】

① Magnetic switch mounting position offset

② Magnetic switch does not match the PLC input (NPN/PNP)

③ Demagnetization of the magnet ring on the piston

④ Signal line broken or loose contact

⑤ Insufficient load voltage

【Diagnostic Methods】

① Bring a magnet near the switch to check whether it triggers

② Check whether the indicator lamp lights

③ Measure the switch output voltage with a multimeter

【Remedies】

① Adjust the magnetic switch position to the piston end position

② Replace with a switch of matching NPN/PNP type

③ Replace the cylinder piston assembly

④ Check the wiring and reconnect it

⑤ Ensure the load voltage is ≥DC21.6V

Pneumatic System Vacuum Cup Fails to Hold the Workpiece

【Symptom】

The cup cannot hold the workpiece stably, or the workpiece drops after being picked

【Possible Causes】

① Insufficient vacuum (vacuum generator undersized)

② Cup worn or aged and cracked

③ Holes, oil contamination or a rough surface on the workpiece

④ Leak in the vacuum line

⑤ Workpiece too heavy / cup diameter too small

⑥ Vacuum breaker valve not fully closed

【Diagnostic Methods】

① Measure the vacuum at the cup with a vacuum gauge (should be ≥-60kPa)

② Check the cup surface for cracks

③ Check the sealing of every line fitting

【Remedies】

① Use a larger vacuum generator or add a vacuum tank

② Replace the cup (check the material: NBR general purpose / silicone high temperature / polyurethane wear resistant)

③ Clean the workpiece surface

④ Inspect the line and replace aged tubing

⑤ Increase the cup diameter or add more cups

⑥ Safety factor ≥4 for horizontal holding, ≥8 for vertical

Pneumatic System Cylinder Cushioning Failure

【Symptom】

Excessive impact at the end of the cylinder stroke; the piston slams into the end cap

【Possible Causes】

① Buffer needle valve adjusted too loose

② Buffer seal worn or damaged

③ Load inertia too large for the cushioning capacity

④ Cylinder speed too fast

【Diagnostic Methods】

① Close the buffer needle valve fully, then open it slowly

② Check the buffer seal

【Remedies】

① Adjust the buffer needle valve (close it fully first, then open 1/4 turn and tune step by step)

② Replace the buffer seal

③ Add an external hydraulic buffer

④ Install a throttle valve to control the cylinder speed

Pneumatic System Tubing Repeatedly Bursting

【Symptom】

Cracks or bursts appear in the pneumatic tubing shortly after it is put into service

【Possible Causes】

① Bending radius too small (less than 6 times the tube outside diameter)

② Tube and fitting mismatch (large outside diameter tolerance)

③ Ambient temperature beyond the tubing temperature rating

④ Tubing aging (PU tubing life is about 2~3 years)

⑤ Line runs close to heat sources or moving parts

【Diagnostic Methods】

① Inspect the rupture location (bend / fitting / abrasion point)

② Measure the bending radius

③ Check the ambient temperature

【Remedies】

① Keep the bending radius ≥6 times the tube outside diameter

② Use tubing and fittings of the same brand

③ In high-temperature environments use nylon or PTFE tubing

④ Replace the tubing at regular intervals (2~3 years)

⑤ Add protective sleeving and secure the line with tube clamps

Excessive Moisture Content in the Pneumatic Air Supply

【Symptom】

Rust, water accumulation or seal swelling inside pneumatic components

【Possible Causes】

① Refrigerant dryer failure (outlet dew point above 10℃)

② Automatic drain valve clogged and not draining

③ Pre-filter element saturated

④ Compressed air not cooled sufficiently

【Diagnostic Methods】

① Check the dryer outlet dew point (normal 2~10℃)

② Check whether the automatic drain valve operates

③ Check how long the filter element has been in service

【Remedies】

① Repair the dryer (check the refrigeration compressor / condenser)

② Clean or replace the automatic drain valve

③ Replace the filter element (recommended every 3~6 months)

④ Add a downstream precision filter (0.01μm filtration)

Insufficient Air Pressure in the Pneumatic System

【Symptom】

System pressure falls more than 0.5MPa below the set value

【Possible Causes】

① Air compressor output insufficient (reduced displacement / loose belt)

② Main pipeline diameter too small

③ Too many leak points in the system

④ Pressure regulator failure

⑤ Filter clogged, causing a large pressure drop

【Diagnostic Methods】

① Measure the pressure at the compressor outlet (should be 0.7~0.8MPa)

② Measure and compare the pressure at each branch

③ Stop production and watch the pressure decay rate to judge the leak volume

【Remedies】

① Overhaul the compressor / replace the filter element

② Increase the main pipe diameter

③ Find and eliminate the leak points

④ Replace the pressure regulator

⑤ Clean or replace the filter

Air Leakage in the Pneumatic System

【Symptom】

Pressure drops rapidly after the system is shut down, with a hissing sound

【Possible Causes】

① Fitting not tightened / damaged O-ring

② Aging and rupture of the tubing

③ Leak at the cylinder end cap seal

④ Internal seal leak of the valve

⑤ Internal seal failure of the push-in fitting

【Diagnostic Methods】

① Locate by sound (listen for the leak)

② Soap bubble leak test

③ Stop production and watch the pressure decay rate

【Remedies】

① Tighten the fitting or replace the O-ring

② Replace the tubing

③ Replace the cylinder end cap seal

④ Replace the valve

⑤ Replace the push-in fitting

Excessive Moisture in the Pneumatic System

【Symptom】

Water collects in the tubing, components rust and seals swell

【Possible Causes】

① Refrigerant dryer failure (dew point above 10℃)

② Automatic drain valve clogged

③ Filter element saturated

④ No drainage slope provided in the line

【Diagnostic Methods】

① Measure the dryer outlet dew point (normal 2~10℃)

② Check the automatic drain valve

③ Check the filter service life

【Remedies】

① Repair the dryer

② Clean or replace the automatic drain valve

③ Replace the filter element

④ Provide a drainage slope in the line (≥1:100)

Insufficient Output Force from the Pneumatic Cylinder

【Symptom】

The cylinder cannot push the load, or it moves slowly

【Possible Causes】

① Low supply pressure

② Cylinder bore size selected too small

③ Piston seal leakage

④ Piston rod binding (misaligned assembly)

⑤ Poor exhaust flow (silencer clogged)

【Diagnostic Methods】

① Measure the inlet pressure at the cylinder

② Push and pull by hand to check the friction

③ Check the alignment of the mounting

【Remedies】

① Raise the supply pressure or enlarge the pipe diameter

② Fit a cylinder with a larger bore

③ Replace the piston seal

④ Adjust the mounting position

⑤ Clean or replace the silencer

Large Impact at the End of the Pneumatic Cylinder Stroke

【Symptom】

The piston strikes the end cap, producing noise and vibration

【Possible Causes】

① Buffer needle valve opened too far

② Buffer seal worn

③ Load inertia too large for the cushioning capacity

④ Cylinder speed too fast

【Diagnostic Methods】

① Close the buffer needle valve fully, then open it slowly and observe

② Check the buffer seal

【Remedies】

① Adjust the buffer needle valve

② Replace the buffer seal

③ Add an external hydraulic buffer

④ Add a throttle valve to control the speed

Pneumatic Cylinder Stuttering

【Symptom】

At low speed the motion stops and starts intermittently

【Possible Causes】

① Poor lubrication (oil mist unit delivering less than 3 drops/min)

② Large piston seal friction

③ Misaligned installation

④ Supply pressure fluctuation

⑤ Poor exhaust flow

【Diagnostic Methods】

① Check the drip rate of the oil mist unit

② Push and pull by hand to feel the resistance

③ Check the coaxiality of the mounting

【Remedies】

① Adjust the oil mist unit to 3~5 drops/min

② Replace with low-friction seals

③ Adjust the installation

④ Add an air receiver tank to stabilize the pressure

⑤ Clean the silencer

Pneumatic Vacuum Cup Fails to Hold

【Symptom】

The cup cannot hold the workpiece stably

【Possible Causes】

① Insufficient vacuum (generator undersized / nozzle clogged)

② Cup worn or aged

③ Holes or oil on the workpiece surface

④ Leak in the line

⑤ Safety factor too small

【Diagnostic Methods】

① Measure the vacuum at the cup with a vacuum gauge (should be ≥-60kPa)

② Check the cup surface

③ Check the line

【Remedies】

① Fit a larger vacuum generator or add a vacuum tank

② Replace the cup (NBR / silicone / polyurethane)

③ Clean the workpiece surface

④ Repair the leak points

⑤ Raise the safety factor (horizontal ≥4, vertical ≥8)

Pneumatic Tubing Rupture

【Symptom】

Cracks or bursts appear in the tubing

【Possible Causes】

① Bending radius too small (less than 6 times the outside diameter)

② Tube and fitting mismatch

③ Ambient temperature out of range

④ Tubing aging (PU life 2~3 years)

⑤ External abrasion / impact

【Diagnostic Methods】

① Check the rupture location

② Check the bending radius

③ Measure the ambient temperature

【Remedies】

① Keep the bending radius ≥6 times the outside diameter

② Use the same brand

③ In high temperatures use nylon or PTFE tubing

④ Replace at regular intervals

⑤ Add protective sleeving

Insufficient Vacuum from the Pneumatic Vacuum Generator

【Symptom】

The vacuum level does not reach the set value

【Possible Causes】

① Nozzle clogged or worn

② Low supply pressure (<0.4MPa)

③ Leak in the vacuum line

④ Silencer clogged

【Diagnostic Methods】

① Check the nozzle

② Measure the supply pressure

③ Check the line sealing

【Remedies】

① Clean or replace the nozzle

② Raise the supply pressure

③ Check and eliminate the leak points

④ Clean the silencer

High Energy Consumption in the Pneumatic System

【Symptom】

The air compressor loads and unloads frequently, and the electricity cost is high

【Possible Causes】

① Extensive leakage in the system

② Air supply not shut off when it is not in use

③ No individual shut-off valves on the branches

④ Unreasonable unloading pressure setting on the compressor

⑤ Small pipe diameter causing a large pressure drop

【Diagnostic Methods】

① Stop production and measure the leakage

② Check whether the line pressure is maintained after the shift ends

【Remedies】

① Find and seal the leak points

② Close the main valve when air is not in use

③ Add a shut-off valve to each branch

④ Optimize the compressor start/stop pressure settings

⑤ Increase the pipe diameter

Insufficient Air Pressure in the Pneumatic System

【Insufficient Air Pressure in the Pneumatic System】

【Symptom】System pressure is below the set value (normal 0.5~0.7MPa), the cylinder acts weakly

【Possible Causes】

① Air compressor output insufficient / efficiency drop; ② Air leak in the line (fitting / damaged tubing); ③ Filter clogged (large pressure loss); ④ Pressure reducing valve set too low / faulty

【Diagnostic Methods】

① Observe the system pressure gauge; ② Close the downstream valve and measure the compressor outlet pressure; ③ Listen for air leaks in the line; ④ Check the filter differential pressure indicator

【Remedies】

① Repair / replace the air compressor (select the size as needed); ② Find and seal the leaks (apply soapy water to the fittings); ③ Clean / replace the filter element (≤40μm); ④ Re-adjust / replace the pressure reducing valve

Insufficient Cylinder Output Force

【Insufficient Cylinder Output Force】

【Symptom】The cylinder pushes the load weakly or cannot push it at all

【Possible Causes】

① Working pressure too low; ② Bore diameter too small (incorrect selection); ③ Worn piston seal causing internal leakage; ④ Load exceeds the rated output force of the cylinder

【Diagnostic Methods】

① Measure the air pressure at the cylinder inlet; ② Calculate the actual output force F=P×A; ③ Check the cylinder for air leaks (at the piston rod)

【Remedies】

① Raise the system pressure to the set value (0.5~0.7MPa); ② Recalculate the load and select a larger bore; ③ Replace the piston seal; ④ Reduce the load or increase the bore

Cylinder Stuttering / Jerking

【Cylinder Stuttering / Jerking】

【Symptom】The cylinder moves in jerks when running at low speed

【Possible Causes】

① Poor lubrication (no oil mist unit / insufficient oil); ② Piston seal too tight (uneven friction); ③ Inlet throttling too restrictive (insufficient supply); ④ Large resistance on the guideway / carriage

【Diagnostic Methods】

① Observe while running at low speed (10~50mm/s); ② Check the drip rate of the oil mist unit; ③ Check the opening of the inlet throttle valve

【Remedies】

① Add an oil mist unit / increase the drip rate (1~3 drops/min); ② Replace the piston seal (hardness HS70±5); ③ Switch to exhaust throttling (inlet fully open); ④ Check the guideway lubrication

Cylinder Not Reversing

【Cylinder Not Reversing】

【Symptom】The cylinder does not act after the solenoid valve is energized

【Possible Causes】

① Burned / jammed solenoid valve coil; ② Pilot air not supplied (double solenoid type); ③ Supply pressure below the minimum working pressure of the valve (0.15MPa); ④ Cylinder seized (rusted after long standstill)

【Diagnostic Methods】

① Listen for the solenoid valve operating sound (a click should be heard); ② Remove the coil and measure the resistance (compare with the nominal value); ③ Check whether there is air pressure in the pilot tube

【Remedies】

① Replace the solenoid valve coil / spool; ② Check whether the pilot tube is supplying air; ③ Ensure the supply pressure is ≥0.15MPa; ④ Disassemble the cylinder and remove the rust / replace it

Cylinder Cushioning Failure

【Cylinder Cushioning Failure】

【Symptom】Large impact noise at the end of the cylinder stroke

【Possible Causes】

① Cushioning seal worn / damaged; ② Cushioning adjustment screw set too loose; ③ Cushioning needle valve clogged; ④ Excessive impact speed (large load inertia)

【Diagnostic Methods】

① Adjust the cushioning screw (clockwise increases the cushioning); ② Listen for air flow noise at the end of the stroke

【Remedies】

① Replace the cushioning seal; ② Tighten the cushioning screw (adjust gradually); ③ Clean the cushioning needle valve; ④ Add an external hydraulic buffer