Common Faults · Quick Diagnosis (Quick Reference)

Quick Diagnosis of Abnormal Equipment Noise

【Quick Diagnosis of Abnormal Equipment Noise】

Possible causes:

① Bearing out of oil / worn / pitted ② Gear tooth surface wear / broken tooth ③ Loose bolts impacting ④ Coupling misalignment ⑤ Poor lubrication causing dry friction

Diagnostic steps:

① Locate by sound: use a stethoscope or hold a screwdriver against each part to identify the sound source

② Judge the sound type: sharp whistling→bearing; periodic knocking→broken gear tooth / loose bolt; continuous friction→poor lubrication

③ Check lubrication: check the oil level / oil condition / whether the oil passage is clear

④ Check fastening: check whether the key bolts are loose

⑤ Measure the vibration spectrum: the spectral peak frequency corresponds to the fault source

Countermeasures:

① Abnormal bearing noise→replenish grease / replace the bearing

② Abnormal gear noise→replace the gear / adjust the backlash

③ Loose bolt→retighten to the specified torque + anti-loosening measures

④ Coupling misalignment→re-align

⑤ Poor lubrication→change the oil / clear the oil passage

Quick Diagnosis of Equipment Vibration

【Quick Diagnosis of Equipment Vibration】

Possible causes:

① Rotor imbalance (mass eccentricity) ② Coupling misalignment ③ Worn bearing with excessive clearance ④ Insufficient foundation stiffness ⑤ Resonance (speed close to the natural frequency)

Diagnostic steps:

① Measure the vibration value: use a vibration meter to measure velocity / displacement and determine whether it exceeds the limit

② Spectrum analysis: strong 1× component→imbalance; strong 2× component→misalignment; high frequency→bearing / gear

③ Check alignment: use a dial indicator or a laser alignment tool to check the coupling

④ Check the foundation: loose anchor bolts / cracked foundation

⑤ Speed variation test: vibration changes markedly as the speed changes→resonance

Countermeasures:

① Imbalance→re-balance dynamically

② Misalignment→adjust by laser alignment

③ Worn bearing→replace the bearing

④ Loose foundation→tighten the anchor bolts / reinforce the foundation

⑤ Resonance→change the speed to avoid the resonance zone or add damping

Quick Diagnosis of Equipment Temperature Rise

【Quick Diagnosis of Equipment Temperature Rise】

Possible causes:

① Insufficient cooling (water cooling blocked / air cooling fan failed) ② Overload operation ③ Poor lubrication causing frictional heat ④ Excessive bearing preload ⑤ Poor heat dissipation environment

Diagnostic steps:

① Measure the temperature: use an infrared thermometer to check the temperature at each location and find the hot spot

② Check cooling: water cooling→check flow rate / water passage blockage; air cooling→check the fan / air duct

③ Check the load: is the current above the rated value, is there any mechanical binding

④ Check lubrication: oil level / oil condition / oil supply normal

⑤ Check the bearing: temperature rise + abnormal noise→bearing problem

Countermeasures:

① Insufficient cooling→clear the water passage / replace the fan

② Overload→reduce the load or fit a larger motor

③ Poor lubrication→replenish oil / change the oil

④ Excessive bearing preload→adjust the preload / use a bearing with larger clearance

⑤ Poor environment→improve ventilation / add thermal insulation

Quick Diagnosis of Equipment Leakage

【Quick Diagnosis of Equipment Leakage】

Possible causes:

① Aged / worn seals ② Scratched or corroded sealing surfaces ③ Excessive pressure forcing the seal open ④ Insufficient bolt preload ⑤ Loose pipe fittings

Diagnostic steps:

① Identify the leaking medium: oil / water / air

② Locate the leak point: wipe it clean and observe, or use fluorescent tracer

③ Check the seals: are the O-rings / oil seals / gaskets aged or deformed

④ Check the sealing surfaces: any scratches / corrosion / deformation

⑤ Check the pressure: is the system pressure above the seal rating

Countermeasures:

① Aged seal→replace the seal

② Damaged sealing surface→lap / replace

③ Excessive pressure→adjust the relief valve to reduce the pressure

④ Loose bolt→retighten to the specified torque

⑤ Loose fitting→tighten or replace the fitting

Quick Diagnosis of Equipment Accuracy Loss

【Quick Diagnosis of Equipment Accuracy Loss】

Possible causes:

① Excessive guideway wear clearance ② Ballscrew wear / preload loosened ③ Worn bearing with excessive clearance ④ Coupling backlash ⑤ Foundation deformation / settlement

Diagnostic steps:

① Measure the repeatability with a dial indicator and judge the magnitude of the error

② Check the guideways: measure the straightness / clearance and look for wear marks

③ Check the ballscrew: measure the axial play and check the preload

④ Check the bearings: turn the machine by hand and feel the clearance

⑤ Check the coupling: look for backlash / wear on the elastic elements

Countermeasures:

① Guideway wear→adjust the gib / replace the guideway

② Ballscrew problem→adjust the preload / replace the ballscrew

③ Worn bearing→replace the bearing

④ Coupling backlash→replace the coupling

⑤ Foundation deformation→re-level / reinforce

Quick Diagnosis of Equipment Failing to Start

【Quick Diagnosis of Equipment Failing to Start】

Possible causes:

① Power supply not connected / missing phase ② Fuse blown / circuit breaker tripped ③ Emergency stop button not reset ④ Start conditions not met (safety door / light curtain) ⑤ Control circuit fault

Diagnostic steps:

① Check the power supply: use a multimeter to measure whether the three-phase voltage is normal

② Check the fuse / breaker: whether it has tripped or blown

③ Check the emergency stop: whether all emergency stop buttons are reset

④ Check the safety signals: whether the safety door / light curtain is normal

⑤ Check the PLC: whether the start conditions are met, read the PLC diagnostics

Countermeasures:

① Power supply problem→restore the supply

② Fuse blown→find the short circuit cause, then replace it

③ Emergency stop→reset the emergency stop

④ Safety signal→close the door / clear the obstruction

⑤ Control fault→check the PLC program / relays

Quick Diagnosis of Sudden Equipment Shutdown

【Quick Diagnosis of Sudden Equipment Shutdown】

Possible causes:

① Overload protection tripped (motor / inverter) ② Emergency stop triggered ③ Safety device actuated (light curtain / door switch) ④ Power interruption ⑤ Shutdown due to an alarm

Diagnostic steps:

① Check the alarm: read the alarm codes on the HMI / PLC / drive

② Check the emergency stop: whether it was pressed by mistake or triggered unintentionally

③ Check the overload: whether the motor thermal relay / drive overload has tripped

④ Check the safety system: whether the light curtain / safety door has been triggered

⑤ Check the power: power failure / missing phase

Countermeasures:

① Overload→find the cause, reduce the load, then reset

② Emergency stop→reset the emergency stop

③ Safety trigger→clear the obstruction, then reset

④ Power→restore the supply

⑤ Alarm→handle it according to the alarm code manual

Quick Diagnosis of Communication Interruption

【Quick Diagnosis of Communication Interruption】

Possible causes:

① Communication cable broken / poor contact ② Loose or oxidized connectors ③ Electromagnetic interference ④ Communication module failure ⑤ Incorrect address / baud rate settings

Diagnostic steps:

① Check the physical connection: whether the network cable / bus plug is loose

② Check the cable: use a multimeter to test continuity, or swap the cable to test

③ Check the connectors: any oxidation or bent pins on the DB9 / RJ45

④ Check interference: whether communication cables are routed separately from the power cables, with shielding and grounding

⑤ Check the settings: whether the station address / baud rate / protocol match

Countermeasures:

① Cable broken→replace the cable

② Loose connector→tighten / replace the connector

③ Interference→add ferrite cores / shield and ground / route separately

④ Module failure→replace the module

⑤ Wrong setting→correct the parameters

Quick Diagnosis of Equipment Alarms

【Quick Diagnosis of Equipment Alarms】

Possible causes:

① Sensor over limit ② Actuator fault ③ Communication anomaly ④ Conflicting logic conditions ⑤ External safety trigger

Diagnostic steps:

① Record the alarm code: the alarm number and description shown on the HMI

② Check the manual: look up the cause and the remedy by the alarm code

③ Classify and handle: warning→may keep running and observe; fault→must stop and be handled

④ Check the alarm history: whether it recurs (intermittent / frequent)

⑤ Check item by item: check each of the possible causes listed in the manual

Countermeasures:

① Sensor over limit→calibrate / replace the sensor

② Actuator fault→repair / replace

③ Communication anomaly→check the cable / module

④ Logic conflict→modify the PLC program

⑤ Safety trigger→clear the obstruction, then reset

Quick Diagnosis of High Oil Temperature

【Quick Diagnosis of High Oil Temperature】

Possible causes:

① Cooler failure (water cooling blocked / air cooling failed) ② Insufficient oil ③ Incorrect oil viscosity ④ Internal leakage generating heat ⑤ High ambient temperature

Diagnostic steps:

① Measure the oil temperature: measure the actual temperature in the tank with a thermometer (normal 30~55℃, alarm above 60℃)

② Check the cooler: water cooling→measure the inlet/outlet water temperature and flow rate; air cooling→check the fan

③ Check the oil level: whether the sight glass is within the normal range

④ Check the oil condition: whether the oil has thinned / thickened / emulsified

⑤ Check internal leakage: measure whether the system pressure drops (internal leakage generates heat)

Countermeasures:

① Cooling failure→clear the water passage / replace the fan

② Insufficient oil→top up to the specified level

③ Wrong viscosity→change to oil of the appropriate viscosity

④ Large internal leakage→replace the pump / replace the seal

⑤ High ambient temperature→add ventilation / thermal insulation

Quick Diagnosis of Insufficient Pressure

【Quick Diagnosis of Insufficient Pressure】

Possible causes:

① Relief valve fault (jammed / broken spring / loosened pressure setting) ② Worn pump with internal leakage ③ Internal leakage in the cylinder / motor ④ External leakage in the line ⑤ Suction blockage / cavitation

Diagnostic steps:

① Measure the system pressure: whether the pressure gauge reaches the set value

② Check the relief valve: whether the adjustment handle is loose, whether the spool moves freely

③ Isolation test: block the load port and measure the pump outlet pressure→distinguish a pump problem from a valve problem

④ Check external leaks: any obvious leakage at the fittings / cylinder body

⑤ Check the suction: whether the filter is clogged, whether the oil level is normal

Countermeasures:

① Relief valve→clean / replace the valve / reset the pressure

② Worn pump→replace the pump

③ Cylinder internal leakage→replace the seal / replace the cylinder

④ External leak→tighten / replace the seal

⑤ Suction blockage→clean / replace the filter element

Quick Diagnosis of Air Bubbles in the Oil

【Quick Diagnosis of Air Bubbles in the Oil】

Possible causes:

① Air leak in the suction line (joint / flange sealing) ② Oil level too low so that air is drawn in ③ Air leak at the pump shaft seal ④ Return line splashing generating bubbles ⑤ Poor defoaming property of the oil

Diagnostic steps:

① Observe the bubbles: watch through a transparent pipe, fine bubbles→dissolved air coming out of solution; large bubbles→air leak on the suction side

② Check the suction line joints: apply soapy water to find the leak points

③ Check the oil level: whether it is below the minimum level

④ Check the pump shaft seal: whether there is an air leak at the seal

⑤ Check the return line: whether it is splashing above the oil surface

Countermeasures:

① Suction air leak→tighten the joints / replace the seal

② Low oil level→top up the oil

③ Shaft seal leak→replace the oil seal

④ Return line splashing→extend the return pipe below the oil surface

⑤ Poor defoaming→change the oil or add a defoamer

Slow Motion Quick Diagnosis

【Slow Motion Quick Diagnosis】

Possible causes:

① Insufficient pump flow (wear / low speed) ② Relief valve relieving prematurely ③ Internal leakage in the directional valve ④ Internal leakage in the cylinder ⑤ Blocked line

Diagnostic steps:

① Measure the actuator speed: time the stroke with a stopwatch and compare it with the normal value

② Check the pump: measure whether the pump outlet flow is normal

③ Check the relief valve: measure whether the pressure is low (premature relieving)

④ Check the directional valve: whether the spool is worn and leaking internally

⑤ Check the cylinder: perform a loaded pressure-hold test, a fast pressure drop→internal leakage

Countermeasures:

① Insufficient pump flow→replace the pump

② Relief valve→adjust the pressure / replace the valve

③ Directional valve internal leakage→replace the valve

④ Cylinder internal leakage→replace the seal / replace the cylinder

⑤ Blocked line→clean / replace the pipe

No Motion Quick Diagnosis

【No Motion Quick Diagnosis】

Possible causes:

① Solenoid valve not switching (burned coil / jammed spool) ② Insufficient pressure ③ Mechanically seized ④ Signal not arriving ⑤ Relief valve fully open

Diagnostic steps:

① Check the solenoid valve: is the coil energized (listen for the click / feel the temperature)

② Check the pressure: does the pressure gauge show pressure

③ Check the signal: use a multimeter to measure the solenoid valve coil voltage

④ Manual switching: press the manual override on the valve, it moves→electrical problem; it does not move→mechanical / pressure problem

⑤ Check the mechanics: turn the machine by hand to check for seizure

Countermeasures:

① Burned coil→replace the coil; jammed spool→clean / replace the valve

② Insufficient pressure→follow the insufficient pressure diagnosis

③ Mechanically seized→remove the obstruction

④ Signal not arriving→check the PLC output / relays

⑤ Relief valve fully open→adjust the pressure

Stuttering Quick Diagnosis

【Stuttering Quick Diagnosis】

Possible causes:

① Air in the system (not fully purged) ② Poor lubrication ③ Large seal friction ④ Large guideway resistance ⑤ Unstable flow at low pressure and low speed

Diagnostic steps:

① Purge the air: open the exhaust valve and cycle several times to bleed off the air

② Check lubrication: are the guideways / cylinder walls lubricated adequately

③ Check the seals: are the seals too tight or worn

④ Measure the resistance: push by hand and feel whether the resistance is uniform

⑤ Check the flow: does the throttle valve have an insufficient minimum stable flow

Countermeasures:

① Air ingress→purge / check the suction for air leaks

② Poor lubrication→add oil / repair the oil line

③ Seal→replace the seal

④ Guideway resistance→adjust the gib / repair the guideway

⑤ Unstable flow→replace with a flow control valve / use a proportional valve

Excessive Noise Quick Diagnosis

【Excessive Noise Quick Diagnosis】

Possible causes:

① Pump drawing air / cavitation ② Pump wear ③ Piping vibration ④ Relief valve whistling ⑤ Low oil level in the tank

Diagnostic steps:

① Locate the sound source: use a stethoscope to determine whether the noise comes from the pump / valve / piping

② Check pump air draw: is the suction filter clogged, is the oil level low

③ Check the piping: are the clamps loose, is the pipe diameter too small

④ Check the relief valve: is it whistling at the critical pressure

⑤ Check the oil: is it emulsified / is the viscosity incorrect

Countermeasures:

① Pump drawing air→clean the filter element / top up the oil

② Pump wear→replace the pump

③ Piping vibration→reinforce the fixing / add flexible hose

④ Relief valve whistling→adjust the pressure / replace the valve

⑤ Poor oil→change the oil

Oil Leak Quick Diagnosis

【Oil Leak Quick Diagnosis】

Possible causes:

① Aged / damaged seals ② Loose fittings ③ Ruptured piping ④ Pressure shock ⑤ Damaged sealing surface

Diagnostic steps:

① Wipe the leaking area clean

② Observe the leak point: fitting / seal / piping / cylinder body

③ Judge the leak type: seepage / dripping / spraying

④ Check the pressure: is a shock pressure damaging the seal

⑤ Check the sealing surface: any scratches / corrosion

Countermeasures:

① Aged seal→replace the seal

② Loose fitting→tighten / replace the fitting

③ Ruptured piping→replace the pipe

④ Pressure shock→add an accumulator / adjust the cushioning

⑤ Damaged sealing surface→lap / replace

Milky Oil Quick Diagnosis

【Milky Oil Quick Diagnosis】

Possible causes:

① Internal leak in the cooler admitting water ② Condensation from ambient humidity ③ Oil is hygroscopic (water-glycol) ④ Water ingress past the seals

Diagnostic steps:

① Take a sample and observe: milky white oil→water emulsification

② Check the cooler: is the water-cooled cooler leaking internally (water enters the oil when the water pressure exceeds the oil pressure)

③ Check the tank breather: does it effectively keep out moisture

④ Test the moisture content: measure the water content of the oil (should be <0.1%)

⑤ Check the environment: is there condensation in a highly humid environment

Countermeasures:

① Cooler internal leak→replace / repair the cooler

② Breather→replace the desiccant / replace the breather

③ Water in the oil→change the oil or use vacuum dehydration

④ Water ingress past the seals→replace the seals

⑤ Humid environment→add dehumidification / insulation

Cylinder Not Moving Quick Diagnosis

【Cylinder Not Moving Quick Diagnosis】

Possible causes:

① No air pressure / insufficient air pressure ② Solenoid valve not switching ③ Mechanically seized ④ Broken cylinder piston ⑤ Control signal not arriving

Diagnostic steps:

① Check the air pressure: does the pressure gauge show pressure (0.4~0.7MPa)

② Check the solenoid valve: is the coil energized, does the manual override switch

③ Check the line: is the tubing kinked / blocked

④ Push the piston rod by hand: determine whether it is mechanically seized

⑤ Check the signal: are the PLC output / relays operating

Countermeasures:

① No air pressure→check the air supply / filter

② Solenoid valve→replace the coil / replace the valve

③ Line→clear it / replace the tube

④ Cylinder damaged→replace the cylinder

⑤ Signal→check the PLC / wiring

Slow Cylinder Speed Quick Diagnosis

【Slow Cylinder Speed Quick Diagnosis】

Possible causes:

① Insufficient supply flow ② Throttle valve opening too small ③ Line too thin / too long ④ Internal leakage in the cylinder ⑤ Poor exhaust flow

Diagnostic steps:

① Check the supply pressure: is it stable at 0.5~0.7MPa

② Check the throttle valve: is the opening too small

③ Check the line: is the pipe diameter adequate, is it kinked

④ Check the exhaust: is the silencer clogged

⑤ Check the cylinder: is the piston seal leaking internally (air bypass)

Countermeasures:

① Insufficient flow→enlarge the pipe diameter / add an air receiver tank

② Throttle valve→open it further

③ Line→fit a larger pipe / shorten it

④ Blocked exhaust→clean / replace the silencer

⑤ Cylinder internal leak→replace the seal / replace the cylinder

Cylinder Impact Quick Diagnosis

【Cylinder Impact Quick Diagnosis】

Possible causes:

① Cushioning valve not adjusted ② Speed too fast ③ Cushioning seal worn ④ No cushioning structure ⑤ Load too light

Diagnostic steps:

① Check the cushioning valve: has it been adjusted properly

② Measure the speed: does it exceed the design speed

③ Check the cushioning seal: is the cushioning chamber seal intact

④ Check the load: is it matched to the cylinder size

⑤ Check the throttling: is the exhaust throttling effective

Countermeasures:

① Cushioning valve→close the cushioning needle valve further

② Speed too fast→close the throttle valve to reduce the speed

③ Cushioning seal→replace the seal / replace the cylinder

④ No cushioning→fit a cylinder with cushioning / add an external buffer

⑤ Load too light→adjust the speed or add a counterweight

Vacuum Cannot Hold Quick Diagnosis

【Vacuum Cannot Hold Quick Diagnosis】

Possible causes:

① Insufficient vacuum ② Cup aged / damaged ③ Uneven workpiece surface ④ Air leak in the vacuum line ⑤ Vacuum pump / generator fault

Diagnostic steps:

① Measure the vacuum level: does the vacuum gauge read the target value (normally above -0.08MPa)

② Check the cup: any cracks / aging / deformation

③ Check the workpiece surface: is it flat / free of oil / free of holes

④ Check the line: are the fittings leaking

⑤ Check the generator: is the supply pressure normal, is the filter element clogged

Countermeasures:

① Low vacuum level→check the pump / generator

② Cup→replace the cup

③ Workpiece surface→clean / change to a different cup type

④ Line leak→tighten / replace the tube

⑤ Generator→clean the filter element / replace the generator

Air Hose Rupture Quick Diagnosis

【Air Hose Rupture Quick Diagnosis】

Possible causes:

① Bend radius too small ② Line abrasion ③ Heat aging ④ Excessive pressure ⑤ Cut at the fitting

Diagnostic steps:

① Check the rupture location: at the fitting / at the bend / at the rubbing point

② Check the bend radius: is it less than 10 times the tube diameter

③ Check for abrasion: is it rubbing against moving parts

④ Check the temperature: is there a heat source nearby

⑤ Check the pressure: does it exceed the line rating

Countermeasures:

① Sharp bend→increase the bend radius / use a flexible-bend-rated tube

② Abrasion→add a protective sleeve / reroute

③ High temperature→use a high-temperature tube / insulate

④ High pressure→reduce the pressure / use a high-pressure tube

⑤ At the fitting→replace the fitting / insert correctly

Solenoid Valve Not Switching Quick Diagnosis

【Solenoid Valve Not Switching Quick Diagnosis】

Possible causes:

① Burned coil ② Jammed spool (contamination / poor lubrication) ③ Insufficient air pressure ④ Manual override jammed ⑤ Wrong voltage

Diagnostic steps:

① Check the coil: feel for magnetism / warmth when energized, measure the resistance with a multimeter

② Manual switching: does the manual override switch the valve

③ Check the air pressure: is the pilot pressure sufficient

④ Check the voltage: does the coil voltage match (DC24V / AC220V)

⑤ Disassemble the spool: check for contamination / rust

Countermeasures:

① Burned coil→replace the coil

② Jammed spool→clean / lubricate / replace the valve

③ Low air pressure→check the air supply

④ Wrong voltage→rewire / replace the coil

⑤ Contamination→add a filter / clean

Motor Not Turning Quick Diagnosis

【Motor Not Turning Quick Diagnosis】

Possible causes:

① Power supply missing a phase / no power ② Winding open circuit / short circuit ③ Mechanically seized ④ Failed start capacitor (single phase) ⑤ Overload protection tripped

Diagnostic steps:

① Check the power supply: use a multimeter to measure the three-phase voltage

② Check the windings: measure whether the three-phase resistances are balanced and the insulation is acceptable

③ Turn the shaft by hand: determine whether it is mechanically seized

④ Check the protection: has the thermal relay / circuit breaker tripped

⑤ Check the capacitor (single phase motor): measure the capacitance with a multimeter

Countermeasures:

① Power supply→restore the supply

② Winding failure→repair / replace the motor

③ Seized→eliminate the mechanical fault

④ Protection tripped→find the overload cause, then reset

⑤ Failed capacitor→replace the capacitor

Motor Overload Quick Diagnosis

【Motor Overload Quick Diagnosis】

Possible causes:

① Mechanical overload ② Incorrect motor parameter settings ③ Frequent starting ④ Low supply voltage ⑤ Damaged bearings with high resistance

Diagnostic steps:

① Measure the current: use a clamp meter to check whether the running current exceeds the rating

② Check the load: turn the machine by hand and feel the resistance

③ Check the voltage: is it low (<90% of rated)

④ Check the starting frequency: is it starting and stopping frequently

⑤ Check the bearings: any abnormal noise / heating

Countermeasures:

① Mechanical overload→reduce the load / repair the mechanics

② Incorrect parameters→reconfigure the inverter / thermal relay parameters

③ Frequent starting→reduce the start/stop cycles / change the motor

④ Low voltage→improve the power supply

⑤ Damaged bearing→replace the bearing

Motor Overheating Quick Diagnosis

【Motor Overheating Quick Diagnosis】

Possible causes:

① Poor heat dissipation (fan failed / air duct blocked) ② Overload ③ Abnormal voltage ④ Bearing heating ⑤ High ambient temperature

Diagnostic steps:

① Measure the temperature: use an infrared thermometer to measure the housing temperature (Class B <80℃, Class F <100℃)

② Check the fan: is the fan turning / damaged

③ Check the air duct: are the cooling fins blocked with dust

④ Measure the current: does it exceed the rating

⑤ Check the environment: is the ventilation good, is the ambient temperature too high

Countermeasures:

① Fan failed→replace the fan

② Blocked air duct→clean out the dust

③ Overload→reduce the load

④ Abnormal voltage→improve the power supply

⑤ High ambient temperature→add ventilation / cooling

Motor Vibration Quick Diagnosis

【Motor Vibration Quick Diagnosis】

Possible causes:

① Rotor imbalance ② Coupling misalignment ③ Unstable base ④ Bearing wear ⑤ Electrical unbalance (missing phase)

Diagnostic steps:

① Measure the vibration value: use a vibration meter to measure velocity / displacement

② Check the base: are the anchor bolts loose, is the foundation sound

③ Check the alignment: is the coupling aligned

④ Decoupling test: uncouple and run the motor unloaded, vibration disappears→load problem; vibration persists→motor problem

⑤ Check the electrical side: are the three-phase currents balanced

Countermeasures:

① Imbalance→re-balance dynamically

② Misalignment→laser alignment

③ Base→tighten / reinforce

④ Bearing→replace the bearing

⑤ Electrical unbalance→check the power supply / windings

Abnormal Motor Noise Quick Diagnosis

【Abnormal Motor Noise Quick Diagnosis】

Possible causes:

① Bearing out of oil / worn ② Fan rubbing the shroud ③ Electromagnetic noise (unstable voltage / uneven air gap) ④ Rotor rubbing the stator ⑤ Coupling rubbing

Diagnostic steps:

① Locate by sound: front / rear end bells / fan shroud / coupling

② Judge the type: periodic mechanical sound→bearing / fan; humming→electromagnetic noise

③ Check the bearing: hold a stethoscope against the end bell, a sharp sound→failed bearing

④ Check the fan: is the fan rubbing the shroud / loose

⑤ Check the air gap: is the rotor rubbing (scuffing noise)

Countermeasures:

① Bearing→replace the bearing / replenish the grease

② Fan rubbing the shroud→adjust the clearance / replace the fan

③ Electromagnetic noise→check the voltage / air gap

④ Rotor scuffing→repair / replace the motor

⑤ Coupling→adjust the alignment / clearance

Low Motor Insulation Quick Diagnosis

【Low Motor Insulation Quick Diagnosis】

Possible causes:

① Moisture ingress (long standstill / humid environment) ② Insulation aging ③ Contamination by oil / dust ④ Winding touching the housing ⑤ Overheating damaging the insulation

Diagnostic steps:

① Measure the insulation: use a megohmmeter to test the insulation to ground (should be >0.5MΩ, >1MΩ for a new motor)

② Check the environment: is it damp / is there water

③ Check for contamination: is there oil or dust in the terminal box / inside the motor

④ Check the temperature: has it been running overheated for a long time

⑤ Distinguish phase-to-phase / to-ground: measure the phase-to-phase and to-ground insulation separately

Countermeasures:

① Moisture ingress→dry it out (heat gun / powered heating)

② Aging→rewind / replace the motor

③ Contamination→clean, then retest the insulation

④ Touching the housing→repair / replace the motor

⑤ Overheating→improve the heat dissipation, then retest

PLC No Output Quick Diagnosis

【PLC No Output Quick Diagnosis】

Possible causes:

① Program logic conditions not satisfied ② Damaged output point ③ Broken wiring ④ Load short circuit burning out the output ⑤ Power supply problem

Diagnostic steps:

① Check the PLC diagnostics: are there any alarms / errors

② Monitor online: is the output point set to ON in the program

③ Measure the output voltage: voltage present→wiring / load problem; no voltage→failed output point

④ Check the program conditions: are the input signals / interposing relays satisfied

⑤ Check the load: is the relay / solenoid valve on the output short circuited

Countermeasures:

① Program→modify the logic / check the inputs

② Failed output point→move to a spare point / replace the module

③ Wiring→repair the wiring

④ Load short circuit→repair the load / change the output point

⑤ Power supply→check the 24V supply

HMI Crash Quick Diagnosis

【HMI Crash Quick Diagnosis】

Possible causes:

① Software bug / memory leak ② Communication interference ③ Unstable power supply ④ Ambient temperature too high ⑤ Aging of the touch panel

Diagnostic steps:

① Restart the HMI: see whether it recovers

② Check the power supply: is the supply voltage stable (DC24V±10%)

③ Check the communications: is the PLC communication normal

④ Check the environment: is the temperature out of limits (generally 0~50℃)

⑤ Check the program: are the screens too large / too many scripts causing insufficient memory

Countermeasures:

① Restart→if it recovers, restart regularly

② Power supply→add a stabilized power supply

③ Communication→check the cables / add ferrite cores

④ Environment→improve the ventilation / cool down

⑤ Aging→replace the touch panel / simplify the screens

Inverter Fault Code Quick Diagnosis

【Inverter Fault Code Quick Diagnosis】

Possible causes:

① Overcurrent (load short circuit / acceleration too fast) ② Overvoltage (deceleration too fast / insufficient braking resistor) ③ Overload ④ Undervoltage ⑤ Damaged IGBT

Diagnostic steps:

① Read the fault code: the Err code displayed on the inverter panel

② Check the manual: look up the specific cause by the code

③ Common codes: OC=overcurrent, OV=overvoltage, OL=overload, LU=undervoltage

④ Check the load: motor insulation / mechanical binding

⑤ Check the parameters: acceleration / deceleration time / V/F curve / motor parameters

Countermeasures:

① Overcurrent→extend the acceleration time / check for a short circuit

② Overvoltage→extend the deceleration time / add a braking resistor

③ Overload→reduce the load / use a larger inverter

④ Undervoltage→improve the power supply

⑤ Damaged IGBT→repair / replace the inverter

Sensor No Signal Quick Diagnosis

【Sensor No Signal Quick Diagnosis】

Possible causes:

① No power supply ② Wiring broken / miswired ③ Sensor damaged ④ Sensing distance too far ⑤ Target material unsuitable

Diagnostic steps:

① Check the power supply: use a multimeter to measure the voltage at the sensor power terminals

② Check the wiring: is the PNP / NPN wiring correct

③ Test the signal: bring a metal plate near the sensor and measure whether the signal terminal changes

④ Check the distance: is the sensing distance within the specification

⑤ Check the target: inductive sensors only detect metal, capacitive sensors can detect non-metals

Countermeasures:

① No power supply→restore the power

② Wiring→rewire

③ Sensor damaged→replace the sensor

④ Distance too far→adjust the mounting position

⑤ Material→change to a suitable sensor type

Sensor False Triggering Quick Diagnosis

【Sensor False Triggering Quick Diagnosis】

Possible causes:

① Mounting distance too short ② Electromagnetic interference ③ Sensitivity too high ④ Background object interference ⑤ Vibration causing a loose contact

Diagnostic steps:

① Check the mounting distance: is it within the specified range

② Check for interference: is there high-power equipment / an inverter nearby

③ Adjust the sensitivity: turn the potentiometer to lower the sensitivity and test

④ Check the background: are there other metal objects / objects entering the sensing zone

⑤ Check the wiring: is the shielded cable grounded, are the connectors secure

Countermeasures:

① Distance too short→adjust the mounting position

② Interference→add shielding / keep away from the interference source / add ferrite cores

③ Sensitivity→lower it

④ Background→add a baffle / adjust the angle

⑤ Loose contact→rewire / reinforce

Encoder Pulse Loss Quick Diagnosis

【Encoder Pulse Loss Quick Diagnosis】

Possible causes:

① Poor cable shielding ② Cable too long ③ Loose connector ④ Electromagnetic interference ⑤ Encoder itself faulty

Diagnostic steps:

① Check the cable: is the shield grounded, is it routed away from the power cables

② Check the connectors: is the DB9 / aviation plug loose

③ Test the signal: use an oscilloscope to check whether the A / B phase waveforms are complete

④ Check for interference: is there an inverter / high-current equipment nearby

⑤ Test with a different encoder: rule out a fault in the encoder itself

Countermeasures:

① Poor shielding→connect the shield to ground properly / use shielded cable

② Cable too long→shorten it / add a repeater

③ Loose connector→tighten / replace the connector

④ Interference→add ferrite cores / route separately / use differential output

⑤ Encoder faulty→replace the encoder

Weld Crack Quick Diagnosis

【Weld Crack Quick Diagnosis】

Possible causes:

① No preheating before welding (thick plate / alloy steel) ② High hydrogen content in the consumable ③ No post-weld holding / de-hydrogenation ④ High restraint stress ⑤ Improper weld bead shape

Diagnostic steps:

① Judge the crack type: hot crack (along the grain / weld center) vs cold crack (heat affected zone / delayed)

② Check the preheating: was it preheated according to the plate thickness (thick plate >100℃)

③ Check the consumable: are low-hydrogen electrodes baked (350℃×1h)

④ Check the process: was de-hydrogenation performed after welding (250~350℃×2h)

⑤ Check the structure: is the restraint too high

Countermeasures:

① Hot crack→control the S / P content / improve the weld bead shape

② Cold crack→preheat + low-hydrogen electrode + de-hydrogenation

③ Consumable→bake the electrodes / change the consumable

④ Restraint→adjust the welding sequence / reduce the restraint

⑤ Shape→increase the groove angle / fill the arc crater

Weld Porosity Quick Diagnosis

【Weld Porosity Quick Diagnosis】

Possible causes:

① Insufficient / interrupted shielding gas ② Oil or rust on the workpiece surface ③ Damp consumable ④ Strong wind blowing away the shielding gas ⑤ Excessive welding speed

Diagnostic steps:

① Check the shielding gas: is the flow adequate (10~20L/min), is the gas line leaking

② Check the workpiece cleanliness: has the groove and 20mm on both sides been degreased and derusted

③ Check the consumable: are the electrodes baked, is the wire rusted

④ Check the environment: is the wind speed >2m/s (wind protection is needed)

⑤ Check the process: are the welding speed / arc length appropriate

Countermeasures:

① Shielding gas→adjust the flow / repair the leak

② Cleaning→grind / degrease

③ Consumable→bake / change the consumable

④ Strong wind→add a wind shield / change the location

⑤ Process→reduce the welding speed / hold the arc shorter

Weld Distortion Quick Diagnosis

【Weld Distortion Quick Diagnosis】

Possible causes:

① Improper welding sequence ② Excessive heat input ③ No reverse distortion preset ④ Insufficient restraint ⑤ Asymmetric weld

Diagnostic steps:

① Judge the distortion type: shrinkage distortion / angular distortion / bending distortion / twisting distortion

② Check the welding sequence: is it symmetric / staggered / back-step

③ Check the heat input: are the current and voltage too high

④ Check the reverse distortion: has reverse distortion been preset

⑤ Check the restraint: is the workpiece held in a fixture

Countermeasures:

① Sequence→symmetric welding / staggered welding / back-step welding

② Heat input→reduce the current / weld in segments

③ Reverse distortion→preset the reverse distortion amount

④ Restraint→add fixture clamping

⑤ After welding→flame straightening / mechanical straightening

Loose Bolt Quick Diagnosis

【Loose Bolt Quick Diagnosis】

Possible causes:

① Not tightened to the specified torque ② No anti-loosening measures ③ Vibration and shock ④ Fatigue elongation of the bolt ⑤ Creep of the joint members

Diagnostic steps:

① Check the loose bolts: measure the residual torque with a torque wrench

② Check the anti-loosening measures: spring washer / locking washer / thread locker

③ Check the vibration: is there severe vibration

④ Check the bolt: any elongation / fatigue cracks

⑤ Check the joint members: any indentation / deformation

Countermeasures:

① Not tightened→retighten to the specified torque

② No anti-loosening→add a locking washer / thread locker

③ Vibration→damp the vibration / use anti-loosening bolts

④ Bolt fatigue→replace the bolt

⑤ Indentation→use higher strength bolts / add a washer

Bearing Wear Quick Diagnosis

【Bearing Wear Quick Diagnosis】

Possible causes:

① Poor lubrication ② Contamination (dust / water ingress) ③ Improper installation (excessive interference / hammering) ④ Overload ⑤ Fatigue spalling

Diagnostic steps:

① Listen to the sound: sharp whistling / irregular noise→wear

② Measure the vibration: the vibration value increases with a prominent high-frequency component

③ Measure the clearance: use a dial indicator to measure the radial clearance and check whether it exceeds the limit

④ Check the lubrication: is the grease degraded / insufficient / contaminated

⑤ Tear down and inspect: any spalling / pitting / cracks on the raceways / rolling elements

Countermeasures:

① Wear→replace the bearing

② Poor lubrication→improve the lubrication

③ Contamination→upgrade the sealing / change the oil

④ Overload→reduce the load / use a larger bearing

⑤ Installation→use heat expansion fitting / proper tools

Guideway Wear Quick Diagnosis

【Guideway Wear Quick Diagnosis】

Possible causes:

① Insufficient lubrication ② Poor protection (dust / chips entering) ③ Overload ④ Insufficient guideway material / hardness ⑤ Improper installation causing local wear

Diagnostic steps:

① Measure the accuracy: are the straightness / parallelism out of tolerance

② Check the wear marks: any scratches / grooves / pitting

③ Check the lubrication: is the oil line clear, is the oil volume sufficient

④ Check the protection: are the covers / wipers intact

⑤ Measure the clearance: is the gib / carriage clearance too large

Countermeasures:

① Light wear→adjust the gib to compensate

② Heavy wear→replace the guideway / re-scrape

③ Lubrication→repair the oil line / add oil

④ Protection→replace the covers / wipers

⑤ Material→use a higher hardness guideway

Ballscrew Backlash Quick Diagnosis

【Ballscrew Backlash Quick Diagnosis】

Possible causes:

① Preload lost ② Ballscrew / nut wear ③ Bearing wear ④ Coupling backlash ⑤ Mounting error

Diagnostic steps:

① Measure the axial play: place a dial indicator against the end face of the ballscrew and push the axis in both directions to measure the play

② Measure the reverse backlash: use a dial indicator to measure the displacement difference between forward and reverse

③ Check the preload: has the double nut preload loosened

④ Check the bearings: is the clearance in the support bearings too large

⑤ Check the coupling: is there backlash

Countermeasures:

① Preload loosened→adjust the preload nut

② Wear→replace the ballscrew and nut set

③ Bearing→replace the bearing

④ Coupling→replace with a zero-backlash coupling

⑤ Software compensation→use the CNC backlash compensation function

Coupling Failure Quick Diagnosis

【Coupling Failure Quick Diagnosis】

Possible causes:

① Misalignment (radial / angular) ② Overload ③ Aging / fatigue of the elastomer ④ Vibration and shock ⑤ Improper installation

Diagnostic steps:

① Check the alignment: use a laser alignment tool or a dial indicator to measure the radial / angular deviation

② Check the elastomer: any cracks / deformation in the jaw spider / diaphragm

③ Check the vibration: any abnormal vibration

④ Check the key / bolts: any shearing / loosening

⑤ Check the temperature rise: any localized heating

Countermeasures:

① Misalignment→re-align

② Elastomer→replace the elastomer / diaphragm

③ Overload→reduce the load / use a larger coupling

④ Vibration→damp the vibration

⑤ Overall→replace the coupling

Belt Slipping Quick Diagnosis

【Belt Slipping Quick Diagnosis】

Possible causes:

① Insufficient tension ② Belt wear / aging ③ Pulley wear ④ Overload ⑤ Oil contamination

Diagnostic steps:

① Check the tension: press the midpoint of the belt, the deflection should be 1~2% of the pulley center distance

② Check the belt: any cracks / wear / glazing

③ Check the pulleys: any wear / oil contamination in the grooves

④ Measure the speed: is the load speed below the rated value

⑤ Check the load: is it overloaded

Countermeasures:

① Tension→adjust the tensioner / adjust the center distance

② Belt→replace the belt (replace as a set)

③ Pulley→clean / replace the pulley

④ Overload→reduce the load

⑤ Oil contamination→clean / protect

Chain Elongation Quick Diagnosis

【Chain Elongation Quick Diagnosis】

Possible causes:

① Wear (pins / bushings) ② Poor lubrication ③ Overload shock ④ Sprocket wear ⑤ Fatigue

Diagnostic steps:

① Measure the elongation: compare a 10-link chain length with the nominal value, elongation >3% requires replacement

② Check the lubrication: is the chain dry / rusted

③ Check the sprocket: any wear / hooking of the tooth profile

④ Check the tensioning: is the sag too large (generally 2~3% of the center distance)

⑤ Check the wear: any wear / cracks on the pins / rollers

Countermeasures:

① Elongation >3%→replace the chain (replace the sprocket at the same time)

② Lubrication→add lubricating oil / repair the oil line

③ Sprocket wear→replace the sprocket

④ Tensioning→adjust the tensioner / adjust the center distance

⑤ Overload→reduce the load

Gear Noise Quick Diagnosis

【Gear Noise Quick Diagnosis】

Possible causes:

① Low gear accuracy (profile / pitch error) ② Tooth surface wear / pitting ③ Insufficient lubrication ④ Assembly error (center distance / parallelism) ⑤ Resonance

Diagnostic steps:

① Listen to the sound: uniform humming→normal; periodic knocking→broken tooth / pitting; sharp whistling→poor lubrication / resonance

② Measure the vibration spectrum: large vibration at the mesh frequency (=number of teeth×speed/60)→accuracy problem

③ Check the tooth surface: any wear / pitting / scuffing

④ Check the assembly: are the center distance / parallelism out of tolerance

⑤ Check the lubrication: oil level / oil condition / oil supply

Countermeasures:

① Low accuracy→use higher accuracy gears

② Damaged tooth surface→replace the gear

③ Lubrication→add oil / change the oil

④ Assembly→readjust

⑤ Resonance→change the speed / increase the damping

Spring Fracture Quick Diagnosis

【Spring Fracture Quick Diagnosis】

Possible causes:

① Fatigue fracture (alternating load) ② Excessive stress (overload / over-compression) ③ Material defect ④ Hydrogen embrittlement (not de-hydrogenated after plating) ⑤ Improper design (spring index / stress concentration)

Diagnostic steps:

① Examine the fracture surface: a fatigue fracture shows beach marks; a brittle fracture surface is flat

② Check the working conditions: is it overloaded / over-compressed

③ Check the material: any inclusions / crack defects

④ Check the surface: any scratches / rust (stress raisers)

⑤ Review the design: spring index / working stress / fatigue strength

Countermeasures:

① Fatigue→replace the spring / reduce the load / add preload

② Overload→reduce the load / use a larger spring

③ Material→use qualified material / a qualified supplier

④ Surface→shot peen / rust proof

⑤ Design→increase the spring index / reduce the stress concentration

Related quick references: Welding DefectsHydraulic SystemsPneumatic SystemsMotor ElectricalEquipment FaultsMotor FaultsStructural Part FaultsSensor FaultsElectrical FaultsMechanical Component FaultsBearing FaultsGear FaultsHydraulic & Pneumatic Valves