Possible causes:
① Bearing out of oil / worn / pitted ② Gear tooth surface wear / broken tooth ③ Loose bolts impacting ④ Coupling misalignment ⑤ Poor lubrication causing dry friction
Diagnostic steps:
① Locate by sound: use a stethoscope or hold a screwdriver against each part to identify the sound source
② Judge the sound type: sharp whistling→bearing; periodic knocking→broken gear tooth / loose bolt; continuous friction→poor lubrication
③ Check lubrication: check the oil level / oil condition / whether the oil passage is clear
④ Check fastening: check whether the key bolts are loose
⑤ Measure the vibration spectrum: the spectral peak frequency corresponds to the fault source
Countermeasures:
① Abnormal bearing noise→replenish grease / replace the bearing
② Abnormal gear noise→replace the gear / adjust the backlash
③ Loose bolt→retighten to the specified torque + anti-loosening measures
④ Coupling misalignment→re-align
⑤ Poor lubrication→change the oil / clear the oil passage
Possible causes:
① Rotor imbalance (mass eccentricity) ② Coupling misalignment ③ Worn bearing with excessive clearance ④ Insufficient foundation stiffness ⑤ Resonance (speed close to the natural frequency)
Diagnostic steps:
① Measure the vibration value: use a vibration meter to measure velocity / displacement and determine whether it exceeds the limit
② Spectrum analysis: strong 1× component→imbalance; strong 2× component→misalignment; high frequency→bearing / gear
③ Check alignment: use a dial indicator or a laser alignment tool to check the coupling
④ Check the foundation: loose anchor bolts / cracked foundation
⑤ Speed variation test: vibration changes markedly as the speed changes→resonance
Countermeasures:
① Imbalance→re-balance dynamically
② Misalignment→adjust by laser alignment
③ Worn bearing→replace the bearing
④ Loose foundation→tighten the anchor bolts / reinforce the foundation
⑤ Resonance→change the speed to avoid the resonance zone or add damping
Possible causes:
① Insufficient cooling (water cooling blocked / air cooling fan failed) ② Overload operation ③ Poor lubrication causing frictional heat ④ Excessive bearing preload ⑤ Poor heat dissipation environment
Diagnostic steps:
① Measure the temperature: use an infrared thermometer to check the temperature at each location and find the hot spot
② Check cooling: water cooling→check flow rate / water passage blockage; air cooling→check the fan / air duct
③ Check the load: is the current above the rated value, is there any mechanical binding
④ Check lubrication: oil level / oil condition / oil supply normal
⑤ Check the bearing: temperature rise + abnormal noise→bearing problem
Countermeasures:
① Insufficient cooling→clear the water passage / replace the fan
② Overload→reduce the load or fit a larger motor
③ Poor lubrication→replenish oil / change the oil
④ Excessive bearing preload→adjust the preload / use a bearing with larger clearance
⑤ Poor environment→improve ventilation / add thermal insulation
Possible causes:
① Aged / worn seals ② Scratched or corroded sealing surfaces ③ Excessive pressure forcing the seal open ④ Insufficient bolt preload ⑤ Loose pipe fittings
Diagnostic steps:
① Identify the leaking medium: oil / water / air
② Locate the leak point: wipe it clean and observe, or use fluorescent tracer
③ Check the seals: are the O-rings / oil seals / gaskets aged or deformed
④ Check the sealing surfaces: any scratches / corrosion / deformation
⑤ Check the pressure: is the system pressure above the seal rating
Countermeasures:
① Aged seal→replace the seal
② Damaged sealing surface→lap / replace
③ Excessive pressure→adjust the relief valve to reduce the pressure
④ Loose bolt→retighten to the specified torque
⑤ Loose fitting→tighten or replace the fitting
Possible causes:
① Excessive guideway wear clearance ② Ballscrew wear / preload loosened ③ Worn bearing with excessive clearance ④ Coupling backlash ⑤ Foundation deformation / settlement
Diagnostic steps:
① Measure the repeatability with a dial indicator and judge the magnitude of the error
② Check the guideways: measure the straightness / clearance and look for wear marks
③ Check the ballscrew: measure the axial play and check the preload
④ Check the bearings: turn the machine by hand and feel the clearance
⑤ Check the coupling: look for backlash / wear on the elastic elements
Countermeasures:
① Guideway wear→adjust the gib / replace the guideway
② Ballscrew problem→adjust the preload / replace the ballscrew
③ Worn bearing→replace the bearing
④ Coupling backlash→replace the coupling
⑤ Foundation deformation→re-level / reinforce
Possible causes:
① Power supply not connected / missing phase ② Fuse blown / circuit breaker tripped ③ Emergency stop button not reset ④ Start conditions not met (safety door / light curtain) ⑤ Control circuit fault
Diagnostic steps:
① Check the power supply: use a multimeter to measure whether the three-phase voltage is normal
② Check the fuse / breaker: whether it has tripped or blown
③ Check the emergency stop: whether all emergency stop buttons are reset
④ Check the safety signals: whether the safety door / light curtain is normal
⑤ Check the PLC: whether the start conditions are met, read the PLC diagnostics
Countermeasures:
① Power supply problem→restore the supply
② Fuse blown→find the short circuit cause, then replace it
③ Emergency stop→reset the emergency stop
④ Safety signal→close the door / clear the obstruction
⑤ Control fault→check the PLC program / relays
Possible causes:
① Overload protection tripped (motor / inverter) ② Emergency stop triggered ③ Safety device actuated (light curtain / door switch) ④ Power interruption ⑤ Shutdown due to an alarm
Diagnostic steps:
① Check the alarm: read the alarm codes on the HMI / PLC / drive
② Check the emergency stop: whether it was pressed by mistake or triggered unintentionally
③ Check the overload: whether the motor thermal relay / drive overload has tripped
④ Check the safety system: whether the light curtain / safety door has been triggered
⑤ Check the power: power failure / missing phase
Countermeasures:
① Overload→find the cause, reduce the load, then reset
② Emergency stop→reset the emergency stop
③ Safety trigger→clear the obstruction, then reset
④ Power→restore the supply
⑤ Alarm→handle it according to the alarm code manual
Possible causes:
① Communication cable broken / poor contact ② Loose or oxidized connectors ③ Electromagnetic interference ④ Communication module failure ⑤ Incorrect address / baud rate settings
Diagnostic steps:
① Check the physical connection: whether the network cable / bus plug is loose
② Check the cable: use a multimeter to test continuity, or swap the cable to test
③ Check the connectors: any oxidation or bent pins on the DB9 / RJ45
④ Check interference: whether communication cables are routed separately from the power cables, with shielding and grounding
⑤ Check the settings: whether the station address / baud rate / protocol match
Countermeasures:
① Cable broken→replace the cable
② Loose connector→tighten / replace the connector
③ Interference→add ferrite cores / shield and ground / route separately
④ Module failure→replace the module
⑤ Wrong setting→correct the parameters
Possible causes:
① Sensor over limit ② Actuator fault ③ Communication anomaly ④ Conflicting logic conditions ⑤ External safety trigger
Diagnostic steps:
① Record the alarm code: the alarm number and description shown on the HMI
② Check the manual: look up the cause and the remedy by the alarm code
③ Classify and handle: warning→may keep running and observe; fault→must stop and be handled
④ Check the alarm history: whether it recurs (intermittent / frequent)
⑤ Check item by item: check each of the possible causes listed in the manual
Countermeasures:
① Sensor over limit→calibrate / replace the sensor
② Actuator fault→repair / replace
③ Communication anomaly→check the cable / module
④ Logic conflict→modify the PLC program
⑤ Safety trigger→clear the obstruction, then reset
Possible causes:
① Cooler failure (water cooling blocked / air cooling failed) ② Insufficient oil ③ Incorrect oil viscosity ④ Internal leakage generating heat ⑤ High ambient temperature
Diagnostic steps:
① Measure the oil temperature: measure the actual temperature in the tank with a thermometer (normal 30~55℃, alarm above 60℃)
② Check the cooler: water cooling→measure the inlet/outlet water temperature and flow rate; air cooling→check the fan
③ Check the oil level: whether the sight glass is within the normal range
④ Check the oil condition: whether the oil has thinned / thickened / emulsified
⑤ Check internal leakage: measure whether the system pressure drops (internal leakage generates heat)
Countermeasures:
① Cooling failure→clear the water passage / replace the fan
② Insufficient oil→top up to the specified level
③ Wrong viscosity→change to oil of the appropriate viscosity
④ Large internal leakage→replace the pump / replace the seal
⑤ High ambient temperature→add ventilation / thermal insulation
Possible causes:
① Relief valve fault (jammed / broken spring / loosened pressure setting) ② Worn pump with internal leakage ③ Internal leakage in the cylinder / motor ④ External leakage in the line ⑤ Suction blockage / cavitation
Diagnostic steps:
① Measure the system pressure: whether the pressure gauge reaches the set value
② Check the relief valve: whether the adjustment handle is loose, whether the spool moves freely
③ Isolation test: block the load port and measure the pump outlet pressure→distinguish a pump problem from a valve problem
④ Check external leaks: any obvious leakage at the fittings / cylinder body
⑤ Check the suction: whether the filter is clogged, whether the oil level is normal
Countermeasures:
① Relief valve→clean / replace the valve / reset the pressure
② Worn pump→replace the pump
③ Cylinder internal leakage→replace the seal / replace the cylinder
④ External leak→tighten / replace the seal
⑤ Suction blockage→clean / replace the filter element
Possible causes:
① Air leak in the suction line (joint / flange sealing) ② Oil level too low so that air is drawn in ③ Air leak at the pump shaft seal ④ Return line splashing generating bubbles ⑤ Poor defoaming property of the oil
Diagnostic steps:
① Observe the bubbles: watch through a transparent pipe, fine bubbles→dissolved air coming out of solution; large bubbles→air leak on the suction side
② Check the suction line joints: apply soapy water to find the leak points
③ Check the oil level: whether it is below the minimum level
④ Check the pump shaft seal: whether there is an air leak at the seal
⑤ Check the return line: whether it is splashing above the oil surface
Countermeasures:
① Suction air leak→tighten the joints / replace the seal
② Low oil level→top up the oil
③ Shaft seal leak→replace the oil seal
④ Return line splashing→extend the return pipe below the oil surface
⑤ Poor defoaming→change the oil or add a defoamer
Possible causes:
① Insufficient pump flow (wear / low speed) ② Relief valve relieving prematurely ③ Internal leakage in the directional valve ④ Internal leakage in the cylinder ⑤ Blocked line
Diagnostic steps:
① Measure the actuator speed: time the stroke with a stopwatch and compare it with the normal value
② Check the pump: measure whether the pump outlet flow is normal
③ Check the relief valve: measure whether the pressure is low (premature relieving)
④ Check the directional valve: whether the spool is worn and leaking internally
⑤ Check the cylinder: perform a loaded pressure-hold test, a fast pressure drop→internal leakage
Countermeasures:
① Insufficient pump flow→replace the pump
② Relief valve→adjust the pressure / replace the valve
③ Directional valve internal leakage→replace the valve
④ Cylinder internal leakage→replace the seal / replace the cylinder
⑤ Blocked line→clean / replace the pipe
Possible causes:
① Solenoid valve not switching (burned coil / jammed spool) ② Insufficient pressure ③ Mechanically seized ④ Signal not arriving ⑤ Relief valve fully open
Diagnostic steps:
① Check the solenoid valve: is the coil energized (listen for the click / feel the temperature)
② Check the pressure: does the pressure gauge show pressure
③ Check the signal: use a multimeter to measure the solenoid valve coil voltage
④ Manual switching: press the manual override on the valve, it moves→electrical problem; it does not move→mechanical / pressure problem
⑤ Check the mechanics: turn the machine by hand to check for seizure
Countermeasures:
① Burned coil→replace the coil; jammed spool→clean / replace the valve
② Insufficient pressure→follow the insufficient pressure diagnosis
③ Mechanically seized→remove the obstruction
④ Signal not arriving→check the PLC output / relays
⑤ Relief valve fully open→adjust the pressure
Possible causes:
① Air in the system (not fully purged) ② Poor lubrication ③ Large seal friction ④ Large guideway resistance ⑤ Unstable flow at low pressure and low speed
Diagnostic steps:
① Purge the air: open the exhaust valve and cycle several times to bleed off the air
② Check lubrication: are the guideways / cylinder walls lubricated adequately
③ Check the seals: are the seals too tight or worn
④ Measure the resistance: push by hand and feel whether the resistance is uniform
⑤ Check the flow: does the throttle valve have an insufficient minimum stable flow
Countermeasures:
① Air ingress→purge / check the suction for air leaks
② Poor lubrication→add oil / repair the oil line
③ Seal→replace the seal
④ Guideway resistance→adjust the gib / repair the guideway
⑤ Unstable flow→replace with a flow control valve / use a proportional valve
Possible causes:
① Pump drawing air / cavitation ② Pump wear ③ Piping vibration ④ Relief valve whistling ⑤ Low oil level in the tank
Diagnostic steps:
① Locate the sound source: use a stethoscope to determine whether the noise comes from the pump / valve / piping
② Check pump air draw: is the suction filter clogged, is the oil level low
③ Check the piping: are the clamps loose, is the pipe diameter too small
④ Check the relief valve: is it whistling at the critical pressure
⑤ Check the oil: is it emulsified / is the viscosity incorrect
Countermeasures:
① Pump drawing air→clean the filter element / top up the oil
② Pump wear→replace the pump
③ Piping vibration→reinforce the fixing / add flexible hose
④ Relief valve whistling→adjust the pressure / replace the valve
⑤ Poor oil→change the oil
Possible causes:
① Aged / damaged seals ② Loose fittings ③ Ruptured piping ④ Pressure shock ⑤ Damaged sealing surface
Diagnostic steps:
① Wipe the leaking area clean
② Observe the leak point: fitting / seal / piping / cylinder body
③ Judge the leak type: seepage / dripping / spraying
④ Check the pressure: is a shock pressure damaging the seal
⑤ Check the sealing surface: any scratches / corrosion
Countermeasures:
① Aged seal→replace the seal
② Loose fitting→tighten / replace the fitting
③ Ruptured piping→replace the pipe
④ Pressure shock→add an accumulator / adjust the cushioning
⑤ Damaged sealing surface→lap / replace
Possible causes:
① Internal leak in the cooler admitting water ② Condensation from ambient humidity ③ Oil is hygroscopic (water-glycol) ④ Water ingress past the seals
Diagnostic steps:
① Take a sample and observe: milky white oil→water emulsification
② Check the cooler: is the water-cooled cooler leaking internally (water enters the oil when the water pressure exceeds the oil pressure)
③ Check the tank breather: does it effectively keep out moisture
④ Test the moisture content: measure the water content of the oil (should be <0.1%)
⑤ Check the environment: is there condensation in a highly humid environment
Countermeasures:
① Cooler internal leak→replace / repair the cooler
② Breather→replace the desiccant / replace the breather
③ Water in the oil→change the oil or use vacuum dehydration
④ Water ingress past the seals→replace the seals
⑤ Humid environment→add dehumidification / insulation
Possible causes:
① No air pressure / insufficient air pressure ② Solenoid valve not switching ③ Mechanically seized ④ Broken cylinder piston ⑤ Control signal not arriving
Diagnostic steps:
① Check the air pressure: does the pressure gauge show pressure (0.4~0.7MPa)
② Check the solenoid valve: is the coil energized, does the manual override switch
③ Check the line: is the tubing kinked / blocked
④ Push the piston rod by hand: determine whether it is mechanically seized
⑤ Check the signal: are the PLC output / relays operating
Countermeasures:
① No air pressure→check the air supply / filter
② Solenoid valve→replace the coil / replace the valve
③ Line→clear it / replace the tube
④ Cylinder damaged→replace the cylinder
⑤ Signal→check the PLC / wiring
Possible causes:
① Insufficient supply flow ② Throttle valve opening too small ③ Line too thin / too long ④ Internal leakage in the cylinder ⑤ Poor exhaust flow
Diagnostic steps:
① Check the supply pressure: is it stable at 0.5~0.7MPa
② Check the throttle valve: is the opening too small
③ Check the line: is the pipe diameter adequate, is it kinked
④ Check the exhaust: is the silencer clogged
⑤ Check the cylinder: is the piston seal leaking internally (air bypass)
Countermeasures:
① Insufficient flow→enlarge the pipe diameter / add an air receiver tank
② Throttle valve→open it further
③ Line→fit a larger pipe / shorten it
④ Blocked exhaust→clean / replace the silencer
⑤ Cylinder internal leak→replace the seal / replace the cylinder
Possible causes:
① Cushioning valve not adjusted ② Speed too fast ③ Cushioning seal worn ④ No cushioning structure ⑤ Load too light
Diagnostic steps:
① Check the cushioning valve: has it been adjusted properly
② Measure the speed: does it exceed the design speed
③ Check the cushioning seal: is the cushioning chamber seal intact
④ Check the load: is it matched to the cylinder size
⑤ Check the throttling: is the exhaust throttling effective
Countermeasures:
① Cushioning valve→close the cushioning needle valve further
② Speed too fast→close the throttle valve to reduce the speed
③ Cushioning seal→replace the seal / replace the cylinder
④ No cushioning→fit a cylinder with cushioning / add an external buffer
⑤ Load too light→adjust the speed or add a counterweight
Possible causes:
① Insufficient vacuum ② Cup aged / damaged ③ Uneven workpiece surface ④ Air leak in the vacuum line ⑤ Vacuum pump / generator fault
Diagnostic steps:
① Measure the vacuum level: does the vacuum gauge read the target value (normally above -0.08MPa)
② Check the cup: any cracks / aging / deformation
③ Check the workpiece surface: is it flat / free of oil / free of holes
④ Check the line: are the fittings leaking
⑤ Check the generator: is the supply pressure normal, is the filter element clogged
Countermeasures:
① Low vacuum level→check the pump / generator
② Cup→replace the cup
③ Workpiece surface→clean / change to a different cup type
④ Line leak→tighten / replace the tube
⑤ Generator→clean the filter element / replace the generator
Possible causes:
① Bend radius too small ② Line abrasion ③ Heat aging ④ Excessive pressure ⑤ Cut at the fitting
Diagnostic steps:
① Check the rupture location: at the fitting / at the bend / at the rubbing point
② Check the bend radius: is it less than 10 times the tube diameter
③ Check for abrasion: is it rubbing against moving parts
④ Check the temperature: is there a heat source nearby
⑤ Check the pressure: does it exceed the line rating
Countermeasures:
① Sharp bend→increase the bend radius / use a flexible-bend-rated tube
② Abrasion→add a protective sleeve / reroute
③ High temperature→use a high-temperature tube / insulate
④ High pressure→reduce the pressure / use a high-pressure tube
⑤ At the fitting→replace the fitting / insert correctly
Possible causes:
① Burned coil ② Jammed spool (contamination / poor lubrication) ③ Insufficient air pressure ④ Manual override jammed ⑤ Wrong voltage
Diagnostic steps:
① Check the coil: feel for magnetism / warmth when energized, measure the resistance with a multimeter
② Manual switching: does the manual override switch the valve
③ Check the air pressure: is the pilot pressure sufficient
④ Check the voltage: does the coil voltage match (DC24V / AC220V)
⑤ Disassemble the spool: check for contamination / rust
Countermeasures:
① Burned coil→replace the coil
② Jammed spool→clean / lubricate / replace the valve
③ Low air pressure→check the air supply
④ Wrong voltage→rewire / replace the coil
⑤ Contamination→add a filter / clean
Possible causes:
① Power supply missing a phase / no power ② Winding open circuit / short circuit ③ Mechanically seized ④ Failed start capacitor (single phase) ⑤ Overload protection tripped
Diagnostic steps:
① Check the power supply: use a multimeter to measure the three-phase voltage
② Check the windings: measure whether the three-phase resistances are balanced and the insulation is acceptable
③ Turn the shaft by hand: determine whether it is mechanically seized
④ Check the protection: has the thermal relay / circuit breaker tripped
⑤ Check the capacitor (single phase motor): measure the capacitance with a multimeter
Countermeasures:
① Power supply→restore the supply
② Winding failure→repair / replace the motor
③ Seized→eliminate the mechanical fault
④ Protection tripped→find the overload cause, then reset
⑤ Failed capacitor→replace the capacitor
Possible causes:
① Mechanical overload ② Incorrect motor parameter settings ③ Frequent starting ④ Low supply voltage ⑤ Damaged bearings with high resistance
Diagnostic steps:
① Measure the current: use a clamp meter to check whether the running current exceeds the rating
② Check the load: turn the machine by hand and feel the resistance
③ Check the voltage: is it low (<90% of rated)
④ Check the starting frequency: is it starting and stopping frequently
⑤ Check the bearings: any abnormal noise / heating
Countermeasures:
① Mechanical overload→reduce the load / repair the mechanics
② Incorrect parameters→reconfigure the inverter / thermal relay parameters
③ Frequent starting→reduce the start/stop cycles / change the motor
④ Low voltage→improve the power supply
⑤ Damaged bearing→replace the bearing
Possible causes:
① Poor heat dissipation (fan failed / air duct blocked) ② Overload ③ Abnormal voltage ④ Bearing heating ⑤ High ambient temperature
Diagnostic steps:
① Measure the temperature: use an infrared thermometer to measure the housing temperature (Class B <80℃, Class F <100℃)
② Check the fan: is the fan turning / damaged
③ Check the air duct: are the cooling fins blocked with dust
④ Measure the current: does it exceed the rating
⑤ Check the environment: is the ventilation good, is the ambient temperature too high
Countermeasures:
① Fan failed→replace the fan
② Blocked air duct→clean out the dust
③ Overload→reduce the load
④ Abnormal voltage→improve the power supply
⑤ High ambient temperature→add ventilation / cooling
Possible causes:
① Rotor imbalance ② Coupling misalignment ③ Unstable base ④ Bearing wear ⑤ Electrical unbalance (missing phase)
Diagnostic steps:
① Measure the vibration value: use a vibration meter to measure velocity / displacement
② Check the base: are the anchor bolts loose, is the foundation sound
③ Check the alignment: is the coupling aligned
④ Decoupling test: uncouple and run the motor unloaded, vibration disappears→load problem; vibration persists→motor problem
⑤ Check the electrical side: are the three-phase currents balanced
Countermeasures:
① Imbalance→re-balance dynamically
② Misalignment→laser alignment
③ Base→tighten / reinforce
④ Bearing→replace the bearing
⑤ Electrical unbalance→check the power supply / windings
Possible causes:
① Bearing out of oil / worn ② Fan rubbing the shroud ③ Electromagnetic noise (unstable voltage / uneven air gap) ④ Rotor rubbing the stator ⑤ Coupling rubbing
Diagnostic steps:
① Locate by sound: front / rear end bells / fan shroud / coupling
② Judge the type: periodic mechanical sound→bearing / fan; humming→electromagnetic noise
③ Check the bearing: hold a stethoscope against the end bell, a sharp sound→failed bearing
④ Check the fan: is the fan rubbing the shroud / loose
⑤ Check the air gap: is the rotor rubbing (scuffing noise)
Countermeasures:
① Bearing→replace the bearing / replenish the grease
② Fan rubbing the shroud→adjust the clearance / replace the fan
③ Electromagnetic noise→check the voltage / air gap
④ Rotor scuffing→repair / replace the motor
⑤ Coupling→adjust the alignment / clearance
Possible causes:
① Moisture ingress (long standstill / humid environment) ② Insulation aging ③ Contamination by oil / dust ④ Winding touching the housing ⑤ Overheating damaging the insulation
Diagnostic steps:
① Measure the insulation: use a megohmmeter to test the insulation to ground (should be >0.5MΩ, >1MΩ for a new motor)
② Check the environment: is it damp / is there water
③ Check for contamination: is there oil or dust in the terminal box / inside the motor
④ Check the temperature: has it been running overheated for a long time
⑤ Distinguish phase-to-phase / to-ground: measure the phase-to-phase and to-ground insulation separately
Countermeasures:
① Moisture ingress→dry it out (heat gun / powered heating)
② Aging→rewind / replace the motor
③ Contamination→clean, then retest the insulation
④ Touching the housing→repair / replace the motor
⑤ Overheating→improve the heat dissipation, then retest
Possible causes:
① Program logic conditions not satisfied ② Damaged output point ③ Broken wiring ④ Load short circuit burning out the output ⑤ Power supply problem
Diagnostic steps:
① Check the PLC diagnostics: are there any alarms / errors
② Monitor online: is the output point set to ON in the program
③ Measure the output voltage: voltage present→wiring / load problem; no voltage→failed output point
④ Check the program conditions: are the input signals / interposing relays satisfied
⑤ Check the load: is the relay / solenoid valve on the output short circuited
Countermeasures:
① Program→modify the logic / check the inputs
② Failed output point→move to a spare point / replace the module
③ Wiring→repair the wiring
④ Load short circuit→repair the load / change the output point
⑤ Power supply→check the 24V supply
Possible causes:
① Software bug / memory leak ② Communication interference ③ Unstable power supply ④ Ambient temperature too high ⑤ Aging of the touch panel
Diagnostic steps:
① Restart the HMI: see whether it recovers
② Check the power supply: is the supply voltage stable (DC24V±10%)
③ Check the communications: is the PLC communication normal
④ Check the environment: is the temperature out of limits (generally 0~50℃)
⑤ Check the program: are the screens too large / too many scripts causing insufficient memory
Countermeasures:
① Restart→if it recovers, restart regularly
② Power supply→add a stabilized power supply
③ Communication→check the cables / add ferrite cores
④ Environment→improve the ventilation / cool down
⑤ Aging→replace the touch panel / simplify the screens
Possible causes:
① Overcurrent (load short circuit / acceleration too fast) ② Overvoltage (deceleration too fast / insufficient braking resistor) ③ Overload ④ Undervoltage ⑤ Damaged IGBT
Diagnostic steps:
① Read the fault code: the Err code displayed on the inverter panel
② Check the manual: look up the specific cause by the code
③ Common codes: OC=overcurrent, OV=overvoltage, OL=overload, LU=undervoltage
④ Check the load: motor insulation / mechanical binding
⑤ Check the parameters: acceleration / deceleration time / V/F curve / motor parameters
Countermeasures:
① Overcurrent→extend the acceleration time / check for a short circuit
② Overvoltage→extend the deceleration time / add a braking resistor
③ Overload→reduce the load / use a larger inverter
④ Undervoltage→improve the power supply
⑤ Damaged IGBT→repair / replace the inverter
Possible causes:
① No power supply ② Wiring broken / miswired ③ Sensor damaged ④ Sensing distance too far ⑤ Target material unsuitable
Diagnostic steps:
① Check the power supply: use a multimeter to measure the voltage at the sensor power terminals
② Check the wiring: is the PNP / NPN wiring correct
③ Test the signal: bring a metal plate near the sensor and measure whether the signal terminal changes
④ Check the distance: is the sensing distance within the specification
⑤ Check the target: inductive sensors only detect metal, capacitive sensors can detect non-metals
Countermeasures:
① No power supply→restore the power
② Wiring→rewire
③ Sensor damaged→replace the sensor
④ Distance too far→adjust the mounting position
⑤ Material→change to a suitable sensor type
Possible causes:
① Mounting distance too short ② Electromagnetic interference ③ Sensitivity too high ④ Background object interference ⑤ Vibration causing a loose contact
Diagnostic steps:
① Check the mounting distance: is it within the specified range
② Check for interference: is there high-power equipment / an inverter nearby
③ Adjust the sensitivity: turn the potentiometer to lower the sensitivity and test
④ Check the background: are there other metal objects / objects entering the sensing zone
⑤ Check the wiring: is the shielded cable grounded, are the connectors secure
Countermeasures:
① Distance too short→adjust the mounting position
② Interference→add shielding / keep away from the interference source / add ferrite cores
③ Sensitivity→lower it
④ Background→add a baffle / adjust the angle
⑤ Loose contact→rewire / reinforce
Possible causes:
① Poor cable shielding ② Cable too long ③ Loose connector ④ Electromagnetic interference ⑤ Encoder itself faulty
Diagnostic steps:
① Check the cable: is the shield grounded, is it routed away from the power cables
② Check the connectors: is the DB9 / aviation plug loose
③ Test the signal: use an oscilloscope to check whether the A / B phase waveforms are complete
④ Check for interference: is there an inverter / high-current equipment nearby
⑤ Test with a different encoder: rule out a fault in the encoder itself
Countermeasures:
① Poor shielding→connect the shield to ground properly / use shielded cable
② Cable too long→shorten it / add a repeater
③ Loose connector→tighten / replace the connector
④ Interference→add ferrite cores / route separately / use differential output
⑤ Encoder faulty→replace the encoder
Possible causes:
① No preheating before welding (thick plate / alloy steel) ② High hydrogen content in the consumable ③ No post-weld holding / de-hydrogenation ④ High restraint stress ⑤ Improper weld bead shape
Diagnostic steps:
① Judge the crack type: hot crack (along the grain / weld center) vs cold crack (heat affected zone / delayed)
② Check the preheating: was it preheated according to the plate thickness (thick plate >100℃)
③ Check the consumable: are low-hydrogen electrodes baked (350℃×1h)
④ Check the process: was de-hydrogenation performed after welding (250~350℃×2h)
⑤ Check the structure: is the restraint too high
Countermeasures:
① Hot crack→control the S / P content / improve the weld bead shape
② Cold crack→preheat + low-hydrogen electrode + de-hydrogenation
③ Consumable→bake the electrodes / change the consumable
④ Restraint→adjust the welding sequence / reduce the restraint
⑤ Shape→increase the groove angle / fill the arc crater
Possible causes:
① Insufficient / interrupted shielding gas ② Oil or rust on the workpiece surface ③ Damp consumable ④ Strong wind blowing away the shielding gas ⑤ Excessive welding speed
Diagnostic steps:
① Check the shielding gas: is the flow adequate (10~20L/min), is the gas line leaking
② Check the workpiece cleanliness: has the groove and 20mm on both sides been degreased and derusted
③ Check the consumable: are the electrodes baked, is the wire rusted
④ Check the environment: is the wind speed >2m/s (wind protection is needed)
⑤ Check the process: are the welding speed / arc length appropriate
Countermeasures:
① Shielding gas→adjust the flow / repair the leak
② Cleaning→grind / degrease
③ Consumable→bake / change the consumable
④ Strong wind→add a wind shield / change the location
⑤ Process→reduce the welding speed / hold the arc shorter
Possible causes:
① Improper welding sequence ② Excessive heat input ③ No reverse distortion preset ④ Insufficient restraint ⑤ Asymmetric weld
Diagnostic steps:
① Judge the distortion type: shrinkage distortion / angular distortion / bending distortion / twisting distortion
② Check the welding sequence: is it symmetric / staggered / back-step
③ Check the heat input: are the current and voltage too high
④ Check the reverse distortion: has reverse distortion been preset
⑤ Check the restraint: is the workpiece held in a fixture
Countermeasures:
① Sequence→symmetric welding / staggered welding / back-step welding
② Heat input→reduce the current / weld in segments
③ Reverse distortion→preset the reverse distortion amount
④ Restraint→add fixture clamping
⑤ After welding→flame straightening / mechanical straightening
Possible causes:
① Not tightened to the specified torque ② No anti-loosening measures ③ Vibration and shock ④ Fatigue elongation of the bolt ⑤ Creep of the joint members
Diagnostic steps:
① Check the loose bolts: measure the residual torque with a torque wrench
② Check the anti-loosening measures: spring washer / locking washer / thread locker
③ Check the vibration: is there severe vibration
④ Check the bolt: any elongation / fatigue cracks
⑤ Check the joint members: any indentation / deformation
Countermeasures:
① Not tightened→retighten to the specified torque
② No anti-loosening→add a locking washer / thread locker
③ Vibration→damp the vibration / use anti-loosening bolts
④ Bolt fatigue→replace the bolt
⑤ Indentation→use higher strength bolts / add a washer
Possible causes:
① Poor lubrication ② Contamination (dust / water ingress) ③ Improper installation (excessive interference / hammering) ④ Overload ⑤ Fatigue spalling
Diagnostic steps:
① Listen to the sound: sharp whistling / irregular noise→wear
② Measure the vibration: the vibration value increases with a prominent high-frequency component
③ Measure the clearance: use a dial indicator to measure the radial clearance and check whether it exceeds the limit
④ Check the lubrication: is the grease degraded / insufficient / contaminated
⑤ Tear down and inspect: any spalling / pitting / cracks on the raceways / rolling elements
Countermeasures:
① Wear→replace the bearing
② Poor lubrication→improve the lubrication
③ Contamination→upgrade the sealing / change the oil
④ Overload→reduce the load / use a larger bearing
⑤ Installation→use heat expansion fitting / proper tools
Possible causes:
① Insufficient lubrication ② Poor protection (dust / chips entering) ③ Overload ④ Insufficient guideway material / hardness ⑤ Improper installation causing local wear
Diagnostic steps:
① Measure the accuracy: are the straightness / parallelism out of tolerance
② Check the wear marks: any scratches / grooves / pitting
③ Check the lubrication: is the oil line clear, is the oil volume sufficient
④ Check the protection: are the covers / wipers intact
⑤ Measure the clearance: is the gib / carriage clearance too large
Countermeasures:
① Light wear→adjust the gib to compensate
② Heavy wear→replace the guideway / re-scrape
③ Lubrication→repair the oil line / add oil
④ Protection→replace the covers / wipers
⑤ Material→use a higher hardness guideway
Possible causes:
① Preload lost ② Ballscrew / nut wear ③ Bearing wear ④ Coupling backlash ⑤ Mounting error
Diagnostic steps:
① Measure the axial play: place a dial indicator against the end face of the ballscrew and push the axis in both directions to measure the play
② Measure the reverse backlash: use a dial indicator to measure the displacement difference between forward and reverse
③ Check the preload: has the double nut preload loosened
④ Check the bearings: is the clearance in the support bearings too large
⑤ Check the coupling: is there backlash
Countermeasures:
① Preload loosened→adjust the preload nut
② Wear→replace the ballscrew and nut set
③ Bearing→replace the bearing
④ Coupling→replace with a zero-backlash coupling
⑤ Software compensation→use the CNC backlash compensation function
Possible causes:
① Misalignment (radial / angular) ② Overload ③ Aging / fatigue of the elastomer ④ Vibration and shock ⑤ Improper installation
Diagnostic steps:
① Check the alignment: use a laser alignment tool or a dial indicator to measure the radial / angular deviation
② Check the elastomer: any cracks / deformation in the jaw spider / diaphragm
③ Check the vibration: any abnormal vibration
④ Check the key / bolts: any shearing / loosening
⑤ Check the temperature rise: any localized heating
Countermeasures:
① Misalignment→re-align
② Elastomer→replace the elastomer / diaphragm
③ Overload→reduce the load / use a larger coupling
④ Vibration→damp the vibration
⑤ Overall→replace the coupling
Possible causes:
① Insufficient tension ② Belt wear / aging ③ Pulley wear ④ Overload ⑤ Oil contamination
Diagnostic steps:
① Check the tension: press the midpoint of the belt, the deflection should be 1~2% of the pulley center distance
② Check the belt: any cracks / wear / glazing
③ Check the pulleys: any wear / oil contamination in the grooves
④ Measure the speed: is the load speed below the rated value
⑤ Check the load: is it overloaded
Countermeasures:
① Tension→adjust the tensioner / adjust the center distance
② Belt→replace the belt (replace as a set)
③ Pulley→clean / replace the pulley
④ Overload→reduce the load
⑤ Oil contamination→clean / protect
Possible causes:
① Wear (pins / bushings) ② Poor lubrication ③ Overload shock ④ Sprocket wear ⑤ Fatigue
Diagnostic steps:
① Measure the elongation: compare a 10-link chain length with the nominal value, elongation >3% requires replacement
② Check the lubrication: is the chain dry / rusted
③ Check the sprocket: any wear / hooking of the tooth profile
④ Check the tensioning: is the sag too large (generally 2~3% of the center distance)
⑤ Check the wear: any wear / cracks on the pins / rollers
Countermeasures:
① Elongation >3%→replace the chain (replace the sprocket at the same time)
② Lubrication→add lubricating oil / repair the oil line
③ Sprocket wear→replace the sprocket
④ Tensioning→adjust the tensioner / adjust the center distance
⑤ Overload→reduce the load
Possible causes:
① Low gear accuracy (profile / pitch error) ② Tooth surface wear / pitting ③ Insufficient lubrication ④ Assembly error (center distance / parallelism) ⑤ Resonance
Diagnostic steps:
① Listen to the sound: uniform humming→normal; periodic knocking→broken tooth / pitting; sharp whistling→poor lubrication / resonance
② Measure the vibration spectrum: large vibration at the mesh frequency (=number of teeth×speed/60)→accuracy problem
③ Check the tooth surface: any wear / pitting / scuffing
④ Check the assembly: are the center distance / parallelism out of tolerance
⑤ Check the lubrication: oil level / oil condition / oil supply
Countermeasures:
① Low accuracy→use higher accuracy gears
② Damaged tooth surface→replace the gear
③ Lubrication→add oil / change the oil
④ Assembly→readjust
⑤ Resonance→change the speed / increase the damping
Possible causes:
① Fatigue fracture (alternating load) ② Excessive stress (overload / over-compression) ③ Material defect ④ Hydrogen embrittlement (not de-hydrogenated after plating) ⑤ Improper design (spring index / stress concentration)
Diagnostic steps:
① Examine the fracture surface: a fatigue fracture shows beach marks; a brittle fracture surface is flat
② Check the working conditions: is it overloaded / over-compressed
③ Check the material: any inclusions / crack defects
④ Check the surface: any scratches / rust (stress raisers)
⑤ Review the design: spring index / working stress / fatigue strength
Countermeasures:
① Fatigue→replace the spring / reduce the load / add preload
② Overload→reduce the load / use a larger spring
③ Material→use qualified material / a qualified supplier
④ Surface→shot peen / rust proof
⑤ Design→increase the spring index / reduce the stress concentration