Half of a linear scale accuracy comes from installation: parallelism to the guideway, head gap and thermal-expansion allowance. Any one out of spec wrecks micron-level performance, so follow the steps and the tolerances.
Install in five steps: clean the mounting faces of burrs and oil film; rough-position the scale against the guideway side with clamps; sweep a dial indicator riding the carriage across the scale base and hold parallelism within 0.05mm over the full length, 0.02mm for precision machines; tighten screws diagonally in three passes while re-measuring; then fit the reading head and set gap and alignment. Finish by jogging five full round trips and watching for even counting and no scraping sounds.
The governing numbers: scale-to-guideway parallelism within 0.05mm per metre general grade, 0.02mm precision grade - out of spec, the head gap wanders along the travel, first wobbling the signal amplitude, then dropping counts. Reading-head gap per the manual, typically 0.8~1.2mm, set with feeler gauges and held within plus or minus 0.1mm; lateral alignment within 0.2mm; and the scan unit square to the guideway within 0.1mm per metre in both planes. Steel-based scales grow about 0.1mm per metre per 10 degrees Celsius, so fix one end and let the other float via slotted holes with 0.5mm clearance - locking both ends bows the scale and ruins it. Air-purged units take clean dry air at 0.05~0.1MPa. Accept the accuracy with a laser interferometer or gauge blocks at 100mm steps.
| Item | Allowable value | Consequence if exceeded |
|---|---|---|
| Scale-to-guideway parallelism | 0.05mm full length, 0.02mm precision | Gap drifts, dropped counts and alarms |
| Reading-head gap | 0.8~1.2mm within ±0.1mm | Weak signal or scale contact |
| Head lateral alignment | Within 0.2mm | Poor scan quality, counting glitches |
| Vertical-plane parallelism | 0.1mm per metre | One-sided gap change, uneven accuracy |
| Thermal allowance | One end fixed, one end free | Both ends locked bows the scale |
| Air purge pressure | 0.05~0.1MPa dry air | Excess pressure disturbs the wiper |
Scale installation rewards patience: sweep the parallelism in both directions and record the larger value, torque the screws diagonally in three passes, and file the measured parallelism, gap and accuracy curve into the machine record - when accuracy degrades later, the archive tells you whether the mount or the scale is guilty.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Installation of position feedback devices per GB/T 5226.1 (IEC 60204-1) and the relevant national machine-tool accuracy inspection standards. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.