Servo motor selection consists of the following 6 steps:
Load mass m, travel stroke S, moving time t, acceleration/deceleration time t1/t2
Friction coefficient μ, efficiency η
Calculate the total inertia at the load end J_load (including workpiece + ball screw + coupling, etc.)
Inertia reflected to the motor shaft: J_load' = J_load / i²
i = N_motor_max × t_acc × 60 / (2π × stroke)
Commonly referenced to the motor rated speed of 3000rpm
Acceleration torque: T_acc = (J_motor + J_load') × 2πN/(60×t_acc)
Friction torque: T_f = mgμ×P/(2πη×i)
Peak torque: T_peak = T_acc + T_f
Selection conditions:
T_peak × 1.2 ≤ T_motor_max (peak torque)
T_continuous ≤ T_motor_rated (continuous torque)
N_max ≤ N_motor_max (maximum speed)
Inertia ratio = J_load' / J_motor
Recommended for servo motors: ≤10
If exceeded → increase the reduction ratio i or select a larger motor
① Ignoring acceleration torque and calculating steady-state torque only
② The inertia ratio is out of limit but goes unnoticed
③ Acceleration/deceleration time is set unreasonably
④ Braking resistor capacity is not taken into account
① Open-loop control, no encoder required
② High torque at low speed, torque drops sharply at high speed
③ Has a resonance range that must be avoided
④ Generates considerable heat, pay attention to heat dissipation
① Calculate the load torque (similar to servo motor selection)
② Determine the required holding torque
③ Consider the speed-torque curve (stepper motor torque falls off severely at high speed)
④ Inertia ratio verification (recommended inertia ratio for stepper motors ≤30)
⑤ Determine the driver current and supply voltage
1.8° (full step) — most commonly used
0.9° — used when higher precision is required
With driver microstepping, 0.036° can be reached
① Stepper motors may develop low-frequency resonance at low speed; avoid the natural frequency
② In actual operation the working torque should be 50%~70% of the holding torque
③ 57 series stepper motors suit small to medium loads
④ 86 series suit larger loads
⑤ Stepper motors are unsuitable for high-speed operation (generally ≤600rpm)
Stepper: low price, open-loop control, good low-speed performance, suitable for low-precision positioning
Servo: high price, closed-loop control, good high-speed performance, suitable for high precision and high speed
① Power P (kW): determined by the required load power
② Synchronous speed: 2-pole (3000rpm) / 4-pole (1500rpm) / 6-pole (1000rpm) / 8-pole (750rpm)
③ Protection rating: IP23 (indoor) / IP54 (general) / IP65 (waterproof)
④ Mounting arrangement: B3 (horizontal) / B5 (flange) / B35 (flange-mounted horizontal)
P = T × n / 9550
Consider a safety factor: P_selected = P_load × K
Take K as 1.1~1.3 (light load) or 1.5~2.0 (heavy load start)
Induction motor starting current is 5~7 times the rated current
Starting torque is 1.5~2.5 times the rated torque
① Standard induction motor with inverter: speed range 3~50Hz
② Inverter-specific motor: adjustable within 0.5~100Hz
③ Long-term low-speed operation requires an independent cooling fan
① General loads: Y series (general purpose)
② Frequent starting: YZ series (metallurgical)
③ High-precision speed control: inverter motor + encoder feedback
Coreless Motor is suited to low inertia and fast response. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Brushless DC Motor is suited to long service life and high efficiency. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Brushed DC Motor is suited to low cost. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Voice Coil Motor is suited to high-frequency linear motion. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Piezoelectric Motor is suited to nanometer-level precision. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Ultrasonic Motor is suited to low speed with high torque. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Switched Reluctance Motor is suited to simple structure. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Permanent Magnet Synchronous Motor is suited to high efficiency. Selection factors: rated power / torque / speed / voltage / protection rating.
Cautions: choose a suitable cooling method and mounting method according to the duty condition.
Linear motor selection essentials:
① Determine the required thrust and continuous thrust
② Determine the maximum speed and acceleration
③ Determine the stroke length
④ Select the motor type (with iron core / ironless / tubular)
⑤ Verify the thrust margin (≥1.3)
⑥ Consider heat dissipation and the cooling method
Linear motors suit linear motion applications with high speed and high acceleration.
DD motor (direct drive motor) selection:
① Determine the load torque and the moment of inertia
② Determine the maximum speed
③ Determine the required positioning accuracy
④ Select the motor model
⑤ Verify the peak torque
A DD motor needs no reducer and has zero backlash, so it suits high-precision rotary positioning.
Related quick references: Ball Screws & Linear GuidesCouplingsPneumatic CylindersGearboxesHydraulic Valve SelectionHydraulic Pump SelectionPneumatic Valve SelectionSensor SelectionPneumaticsConveyingMotorsHydraulicsTransmission