Gear Pump is suited to low-pressure, high-flow applications. Maximum pressure: 16MPa, volumetric efficiency: 0.85.
Selection factors: displacement (ml/r), rated pressure, speed range, drive power.
Calculation formula: P(kW)=p(MPa)×Q(L/min)/(60×η)
Vane Pump is suited to medium-pressure applications. Maximum pressure: 21MPa, volumetric efficiency: 0.88.
Selection factors: displacement (ml/r), rated pressure, speed range, drive power.
Calculation formula: P(kW)=p(MPa)×Q(L/min)/(60×η)
Plunger Pump is suited to high-pressure applications. Maximum pressure: 35MPa, volumetric efficiency: 0.92.
Selection factors: displacement (ml/r), rated pressure, speed range, drive power.
Calculation formula: P(kW)=p(MPa)×Q(L/min)/(60×η)
Screw Pump is suited to low-noise applications. Maximum pressure: 10MPa, volumetric efficiency: 0.8.
Selection factors: displacement (ml/r), rated pressure, speed range, drive power.
Calculation formula: P(kW)=p(MPa)×Q(L/min)/(60×η)
Related quick references: Motor SelectionBall Screws & Linear GuidesCouplingsPneumatic CylindersGearboxesHydraulic Valve SelectionPneumatic Valve SelectionSensor SelectionPneumaticsConveyingMotorsHydraulicsTransmission