Motor vibration and loose hold-down bolts: measurement and fixes

Before blaming the bearings or the coupling, check the feet. Loose hold-down bolts and floating shims are the cheapest and most common reason a healthy motor shakes - here is how to measure vibration and verify the foundation.

1. How it works

Measure velocity RMS at the bearing housings in horizontal, vertical and axial directions. As a working reference, rigidly mounted machines above frame size 132 should stay near 2.8mm/s and free-suspended near 4.5mm/s per GB/T 10068; many plants set an internal alarm at 4.5 and a stop at 7.1mm/s. Note the speed and the position: a dominant once-per-rev component points to unbalance, twice-per-rev to misalignment, and broadband jitter that tracks tightness points to looseness.

2. Practice and pitfalls

Loose feet turn the stiff mounting into a spring and can drop the natural frequency onto the running speed, multiplying the amplitude. Check all four bolt torques (about 60~80N·m for M12 and 120~150N·m for M16 unless the maker says otherwise), then slide a 0.05mm feeler under each foot - a gap deeper than 3mm calls for re-levelling and re-grouting. Before swapping the motor, do the disconnect test: uncouple and run the motor alone. If it runs smooth, the coupling or the driven load is the culprit, not the motor.

3. Vibration troubleshooting quick table

SignaturePoints toVerificationAction
Once-per-rev dominantUnbalanceSpectrum readoutField balancing
Twice-per-rev dominantMisalignmentLaser alignment checkRe-align to 0.05mm
Broadband, varies over timeLoose feet or shimsTorque and feeler checkTighten, level, re-grout
Rises steeply with speedNear resonanceRun-up sweepStiffen the foundation
Smooth when uncoupledLoad side problemInspect coupling and loadFix driven machine

4. Notes

Fix the measuring points, the direction and the operating condition so numbers stay comparable. After tightening, re-measure, log the torque, and recheck after a month for back-off. Rebuild the vibration history whenever the motor or the foundation is disturbed.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor vibration limits and measurement per GB/T 10068, mechanical vibration evaluation per ISO 20816, machinery safety per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Judging vibration by feel or ear: every speed and frame has its own baseline, instruments decide
② Tightening bolts without checking gaps: a floating shim bows the foot, feeler checks matter more than torque
③ Swapping the motor straight away: the installation or load issue remains and kills the new bearings too

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL