Before blaming the bearings or the coupling, check the feet. Loose hold-down bolts and floating shims are the cheapest and most common reason a healthy motor shakes - here is how to measure vibration and verify the foundation.
Measure velocity RMS at the bearing housings in horizontal, vertical and axial directions. As a working reference, rigidly mounted machines above frame size 132 should stay near 2.8mm/s and free-suspended near 4.5mm/s per GB/T 10068; many plants set an internal alarm at 4.5 and a stop at 7.1mm/s. Note the speed and the position: a dominant once-per-rev component points to unbalance, twice-per-rev to misalignment, and broadband jitter that tracks tightness points to looseness.
Loose feet turn the stiff mounting into a spring and can drop the natural frequency onto the running speed, multiplying the amplitude. Check all four bolt torques (about 60~80N·m for M12 and 120~150N·m for M16 unless the maker says otherwise), then slide a 0.05mm feeler under each foot - a gap deeper than 3mm calls for re-levelling and re-grouting. Before swapping the motor, do the disconnect test: uncouple and run the motor alone. If it runs smooth, the coupling or the driven load is the culprit, not the motor.
| Signature | Points to | Verification | Action |
|---|---|---|---|
| Once-per-rev dominant | Unbalance | Spectrum readout | Field balancing |
| Twice-per-rev dominant | Misalignment | Laser alignment check | Re-align to 0.05mm |
| Broadband, varies over time | Loose feet or shims | Torque and feeler check | Tighten, level, re-grout |
| Rises steeply with speed | Near resonance | Run-up sweep | Stiffen the foundation |
| Smooth when uncoupled | Load side problem | Inspect coupling and load | Fix driven machine |
Fix the measuring points, the direction and the operating condition so numbers stay comparable. After tightening, re-measure, log the torque, and recheck after a month for back-off. Rebuild the vibration history whenever the motor or the foundation is disturbed.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor vibration limits and measurement per GB/T 10068, mechanical vibration evaluation per ISO 20816, machinery safety per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.