A backup that cannot restore is worse than none - wrong version, missing configuration, no comments. Seven checks, storage rules and a rehearsal schedule that make every backup count.
Check seven things before filing a backup. Identity: file name carries unit number, date and version, with author and change summary in the register. Completeness: program blocks, hardware configuration, HMI project and drive parameters - miss one and restoration turns into field archaeology. Currency: back up what is actually running online, not some stale laptop project. Compilability: reopen offline and compile - a file that does not build is a broken file. Comments and symbol tables present, or nobody will dare use it in three years. DB initial values recorded for post-restore comparison. And a rehearsal: restore once to a spare CPU or simulator to prove it runs.
Storage follows three rules. Two locations - one on site, one in the server room or cloud, never a single USB stick. A version chain of the last three to five releases, because the newest edit may be the one that needs undoing. Timely updates within 24 hours of any change plus a quarterly full pass; media replaced every 3~5 years. Twice a year, restore one unit end to end and file the drill. Label the cabinet door with backup location and version so a night-shift electrician can find it - the value of all this is redeemed the moment a CPU dies or a program is wiped.
| Check item | Standard | If missing | How to verify |
|---|---|---|---|
| Version identity | Unit + date + version | Wrong file restored | Naming rule and register |
| Four artefacts complete | Code, config, HMI, drives | Field rework after restore | Tick the list |
| Matches the running copy | Online program as of today | Old version overwrites edits | Compare tool |
| Compiles offline | Build passes | File quietly corrupt | Compile right after backup |
| Comments and symbols | Block notes, tag tables | Unusable in three years | Sample a few blocks |
Four artefacts, with comments, two locations, a version chain, a half-yearly drill. The standard is simple: a stranger with the register restores the machine inside half an hour.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: PLC programming and project files per GB/T 15969.3 (IEC 61131-3), technical documentation for machinery per the documentation clauses of GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.