When position feedback goes wrong the least harm is unstable dimensions and the worst is a crash or runaway. This page organises the check order for full-closed and semi-closed loops alike, with a four-step supply, signal, homing, mechanics method and typical numbers.
First identify the loop type. Semi-closed loops feed back only the motor encoder, hiding screw backlash and coupling slip; full-closed loops read a linear scale on the table, exposing mechanical error but also feeding machine vibration straight into the loop. In a full-closed loop, oscillation alarms first implicate scale mounting: keep straightness within 0.05 mm over full travel and the reading gap at 0.5 to 1.5 mm per the maker, while semi-closed dimension errors point to backlash or couplings first.
Then apply the four steps. Supply: encoder 5 V rails must read 4.75 to 5.25 V and 24 V scale supplies within 10 percent, since droop causes random alarms. Signal: check A/B/Z or serial feedback on the scope or drive diagnostics; clean at standstill, even edges in motion. Homing: home three times and compare stop positions; a decel-switch to Z-pulse distance over one revolution causes wander. Mechanics: push the table against a dial gauge and compare feedback change with gauge reading; a mismatch means the scale is loose.
Classic field cases: dimensions degrading along travel usually mean a dirty scale — wipe once, one direction, with lint-free cloth and absolute alcohol, never scrub back and forth. Random micron jitter means shielding and earthing; route scale cables in their own trough, bonded at both ends. A constant offset after a crash means the home dog moved; re-home. And if displayed travel is a fixed ratio off from actual travel, someone touched the full/semi-closed ratio parameters — compare commanded versus measured stroke.
| Symptom | Direction | Criterion | Action |
|---|---|---|---|
| Dimensions drift along travel | Dirty scale | Error accumulates with stroke | Wipe once with alcohol |
| Random micron jitter | Shielding and earth | Feedback flickers at rest | Bond shields, separate troughs |
| Homing point wanders | Dog or Z issue | Three homes differ | Re-set dog and switch spacing |
| Oscillation on enable | Full-loop vibration | Normal with scale open | Fix straightness and gap |
| Coordinates off by fixed ratio | Feedback ratio params | Constant stroke ratio | Restore electronic gearing |
| Intermittent feedback alarms | Supply droop | 5 V below 4.75 V | Check PSU and connectors |
| One-way dimension error | Backlash | Semi-loop reverse error | Compensate or rebuild nut |
| Fixed offset after crash | Home dog shifted | Constant offset value | Re-home and lock the dog |
The core discipline is layering before touching anything: identify the loop type, walk the four steps, and record numbers at each one. Never mask an unknown cause by cycling parameters; that turns a simple fault into a mystery.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machine electrical systems per GB/T 5226.1 (IEC 60204-1); scale installation and acceptance per GB/T 17421 test series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.