Veterans swear by analogue meters, newcomers never touch anything but digital. Each has jobs the other cannot do well - know both, carry both.
The physics differs. An analogue meter draws current from the circuit (about 20kΩ/V on DC volts) and its ohms range outputs 3V or more, which forward-biases semiconductor junctions and makes diode and transistor tests visible as swing. A digital meter presents 10MΩ, hardly disturbing the circuit, reads precisely and protects itself well, but its ohms range only offers a few tenths of a volt - too little for junction behaviour. Analogue meters work without batteries for volts and amps and show trends at a glance; digitals give numbers, capacitance and frequency.
Use each where it wins. Digital: precision millivolts, millivolt drop checks across joints, capacitance, frequency, fast auto-ranging surveys. Analogue: capacitor condition from the charge swing, thermistors and photoresistors as smooth trends, thyristor and rectifier testing where the high ohms-range voltage can trigger the gate, and stable readings beside inverters where a basic digital jitters. Measuring drive output with an ordinary digital lies badly - use a true-RMS meter or the analogue one. Carry a CAT III 600V true-RMS digital as the daily workhorse, keep one analogue per crew for semiconductors and noise, and cross-check any disagreement by re-examining range and mode before doubting the circuit.
| Task | Best meter | Why | Note |
|---|---|---|---|
| Precision millivolts, joint drop | Digital | 10MΩ input, no disturbance | True-RMS model preferred |
| Capacitor charge check | Analogue | Swing shows charge visibly | Discharge first |
| Thyristor, rectifier test | Analogue | High ohms-range voltage triggers gate | Mind polarity and range |
| Readings beside drives | Analogue or true-RMS digital | Basic digitals jitter on PWM | Never trust plain mode on drive output |
| Voltage with dead batteries | Analogue | V and A need no battery | Calibrate the movement yearly |
Precision goes digital, components go analogue, noise goes analogue, drive output goes true-RMS. Keep both meters, check settings before blaming readings, and baseline every new meter against the reference once a year.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Multimeter safety per GB/T 4793.1 (IEC 61010-1) with CAT ratings, instrument specifications per GB/T 7676 and GB/T 13978, machinery safety per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.