GB/T 3836.15: installing electrical equipment in explosive atmospheres

In hazardous areas, one missing sealing ring is an accident waiting to happen. This page summarises GB/T 3836.15 on area classification, Ex equipment selection, installation and acceptance.

1. How it works

Areas are classified per GB/T 3836.14: gas zones 0 (continuous), 1 (occasional in normal operation), 2 (short periods only under fault), and dust zones 20/21/22 correspondingly. Equipment selection matches the zone: zone 0 permits only Ex ia intrinsic safety; zone 1 allows Ex d flameproof, Ex e increased safety, Ex ia and Ex p pressurisation; zone 2 additionally permits Ex n. A marking such as Ex d IIB T4 Gb means flameproof, gas group IIB, temperature class T4 (135 C), protection level Gb for zone 1. The temperature class must always sit below the gas ignition temperature (hydrogen at 560 C accepts T1 and up; acetylene at 305 C needs T2 or better). Gas group and temperature class are independent and both must pass.

2. Numbers and practice

Installation essentials. Flameproof Ex d: never paint or wrap the flameproof joint faces — a damaged face scraps the unit; cable entries require Ex glands matched to cable diameter (reducing seals for thin cables), one cable per entry, and every spare entry plugged. Increased safety Ex e: terminals torqued to the maker specification (loosening is the deadly failure mode) and never two dissimilar conductors in one terminal unless the maker permits. Intrinsic safety Ex ia/ib: intrinsically safe circuits routed at least 50 mm from non-IS wiring or behind separators, cable capacitance and inductance within the associated apparatus limits (Cc+Ci ≤ Co), and blue-marked cabling. Every device must carry its Ex marking and certificate number.

3. Pitfalls and fixes

Acceptance and maintenance red lines: verify certificates against nameplates item by item; check every entry is glanded or plugged; inspect flameproof faces undamaged and unpainted; confirm earthing jumpers (6 mm² or more across flanged joints); and audit IS segregation against drawings. Maintenance: never open flameproof enclosures live or without gas measurement; re-inspect and re-coat repaired faces with type 204-1 rust preventive oil — never ordinary grease; restore spring washers at specified torques; replace components only with certified equivalents. Post-repair checks follow GB/T 3836.13 with records kept for the equipment lifetime.

4. Ex installation checklist quick reference

CheckRequirementMethodPass criterion
Ex certificateNameplate matches certificateOne-by-one auditUncertified units removed
Cable entriesGlands and plugs completePer-entry inspectionSpares plugged
Sealing ringsMatched to cable diameterVisual plus measurementWithin gap limits
Flameproof facesUndamaged, unpaintedVisual and feelCoated with 204-1 oil
Terminal torquePer maker valuesTorque wrench samplingPriority on Ex e
IS segregation50 mm gap or separatorVisual against drawingsBlue marking complete
Earthing jumpers6 mm² across flangesVisual and resistanceContinuous, rust-free
Repair recordsPer GB/T 3836.13Archive auditComplete and traceable

5. Notes

For installation, modification and maintenance in gas and dust atmospheres alike. Details are destiny in Ex work: one open entry or one painted face is an ignition source. Personnel need certified training, and repair records stay traceable for life.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Standard: GB/T 3836.15 (Explosive atmospheres — Part 15: Electrical installations design, selection and erection), with GB/T 3836.14 for zoning and GB/T 3836.13 for repair; internationally IEC 60079. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Painting flameproof faces against rust: the joint gap is destroyed and so is the protection; only type 204-1 oil is permitted
② Leaving spare cable entries open: gas enters the terminal compartment through the hole; every spare entry gets a plug — one plug is one line of defence
③ Swapping in ordinary components: uncontrolled temperature and sparking turn them into ignition sources; replace only with certified equivalents and log it

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.