A servo that refuses to move usually hides in the enable chain or the brake, not in the drive itself. Panel first, enable, brake, command and encoder - an order that finds the fault in half an hour.
Start at the drive. No display: check the control supply - many servos split control power from main power, so a tripped main feed leaves the panel alive while the bus is dead, and vice versa. Display alive but the servo-ready lamp off: the enable is missing - trace the enable input back through the PLC output and the safety chain, since guards and e-stops sit in series with it. An alarm code: handle it by code. Enable given, command given, still no motion: walk the command chain. And note the fake fault: a braked motor cannot be turned by hand until the brake releases - the most common false report of a dead servo.
Work the enable and brake with a meter: the enable terminal voltage against its common, the interposing relay, the safety chain states. For the brake, measure the coil voltage - DC 24V typically - and its rectifier; a dead coil or rectifier locks the shaft forever, and some controls release the brake on a delay after enable, so measure after the delay. Then the command chain by mode: position - pulses present, wiring correct, electronic gear ratio sane (a ratio off by 1000 looks like nothing moves); speed - analogue command and zero-clamp settings; torque - command present but a speed limit of zero means no rotation no matter the torque. Encoder leads and absolute battery come next, and finally limits: software or hardware limits refuse commands and look exactly like a frozen axis.
| Symptom | Points to | Verification | Action |
|---|---|---|---|
| No display on drive | Control supply | Measure control power terminals | Fuse and wiring |
| Ready lamp off | Enable chain open | Terminal voltage, PLC output | Restore enable path |
| Shaft locked by hand | Brake not released | Brake coil voltage | Brake circuit or new brake |
| Command given, no alarm, no motion | Command chain or gear ratio | Pulse or analogue check | Fix wiring and parameters |
| Jitter or lost steps | Encoder contact | Reseat, check shield | Clean, secure or re-cable |
Panel, enable, brake, command, encoder, limits - in that order. More than half of dead servos live in the enable chain or the brake; the drive itself rarely. Never force the shaft of a braked motor - release the brake and secure the load first.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: AC servo systems per GB/T 16439, control functions per GB/T 5226.1 clause 9. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.