Servo motor will not turn: the fixed diagnostic order

A servo that refuses to move usually hides in the enable chain or the brake, not in the drive itself. Panel first, enable, brake, command and encoder - an order that finds the fault in half an hour.

1. How it works

Start at the drive. No display: check the control supply - many servos split control power from main power, so a tripped main feed leaves the panel alive while the bus is dead, and vice versa. Display alive but the servo-ready lamp off: the enable is missing - trace the enable input back through the PLC output and the safety chain, since guards and e-stops sit in series with it. An alarm code: handle it by code. Enable given, command given, still no motion: walk the command chain. And note the fake fault: a braked motor cannot be turned by hand until the brake releases - the most common false report of a dead servo.

2. Practice and pitfalls

Work the enable and brake with a meter: the enable terminal voltage against its common, the interposing relay, the safety chain states. For the brake, measure the coil voltage - DC 24V typically - and its rectifier; a dead coil or rectifier locks the shaft forever, and some controls release the brake on a delay after enable, so measure after the delay. Then the command chain by mode: position - pulses present, wiring correct, electronic gear ratio sane (a ratio off by 1000 looks like nothing moves); speed - analogue command and zero-clamp settings; torque - command present but a speed limit of zero means no rotation no matter the torque. Encoder leads and absolute battery come next, and finally limits: software or hardware limits refuse commands and look exactly like a frozen axis.

3. Servo no-motion quick table

SymptomPoints toVerificationAction
No display on driveControl supplyMeasure control power terminalsFuse and wiring
Ready lamp offEnable chain openTerminal voltage, PLC outputRestore enable path
Shaft locked by handBrake not releasedBrake coil voltageBrake circuit or new brake
Command given, no alarm, no motionCommand chain or gear ratioPulse or analogue checkFix wiring and parameters
Jitter or lost stepsEncoder contactReseat, check shieldClean, secure or re-cable

4. Notes

Panel, enable, brake, command, encoder, limits - in that order. More than half of dead servos live in the enable chain or the brake; the drive itself rarely. Never force the shaft of a braked motor - release the brake and secure the load first.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: AC servo systems per GB/T 16439, control functions per GB/T 5226.1 clause 9. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Forcing the shaft on a braked servo: the gearbox takes the damage - release the brake and secure the load before touching
② Power-cycling past an uncleared alarm: encoder or overcurrent faults worsen with each retry - resolve by code first
③ Changing the electronic gear ratio casually: command units shift and positioning crashes into the machine - convert and verify the scale

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.