The CE certificate is easy; the technical file is where reviewers push back, and most rejections come from missing or contradictory documents. This page lists the file contents, the drafting essentials for each part and the rejection patterns to avoid.
For machinery under Directive 2006/42/EC the technical file must include a product description with intended use and limits, a risk assessment per EN ISO 12100 covering the whole life cycle with severity-times-probability scoring and the three-step hierarchy of measures, a list of applied harmonised standards with their current versions, drawings that match the as-built machine, calculations (safety distances, braking distances, strength), test reports with real measured values per EN 60204-1 chapter 18, an instruction handbook in the languages of every target market, and the Declaration of Conformity. Keep the file at least ten years after the last unit was built.
Drafting essentials. The risk assessment is the core document: walk every station and function, name the specific safeguards fitted, and explain residual risk — a template copied without machine-specific measures is spotted instantly. Electrical content follows EN 60204-1: schematics identical to the machine, conductor colours and sizes, e-stop category, and safety-function performance level calculated per EN ISO 13849-1 with the calculation archived (SISTEMA files are standard practice). Cross-consistency matters as much as completeness: the safety distances drawn, the maintenance intervals written and the measures claimed must all corroborate each other.
Rejection patterns in order: drawings that no longer match the machine after design changes (fix with a change-management process that updates every affected file); formalistic risk assessments lacking concrete measures; missing language versions of the manual; test reports reading only passed with no data; PL calculations without a working shown; and expired standard versions against the current Official Journal list. The discipline is simple: data filled in, files cross-referenced, changes synchronised — repairing a rejection costs far more than doing it right once.
| File | Basis | Key content | Common problem |
|---|---|---|---|
| Product description | Machinery Directive | Use and restrictions | Limits omitted |
| Risk assessment | EN ISO 12100 | Life-cycle hazards and measures | Formalistic templates |
| Standards list | OJ harmonised list | Valid versions | Expired citations |
| Design drawings | As-built match | Electrical, pneumatic, hydraulic | Changes not synced |
| Calculations | Relevant EN standards | Distances, braking | No working shown |
| Test report | EN 60204-1 ch.18 | Insulation, bonding, hipot values | Passed without data |
| Instruction handbook | Directive Annex I | Target-market languages | Missing versions |
| DoC | Directive format | Signatory details | Format elements missing |
For machinery bound for the EU market. The golden rules: risk assessment first, standards list as the frame, real data in every report, cross-references closed and changes synchronised. Archive everything for ten years; the cost of a rejection dwarfs doing it properly the first time.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machinery Directive 2006/42/EC and its harmonised standards; electrical safety per EN 60204-1 (national counterpart GB/T 5226.1); risk assessment per EN ISO 12100; safety controls per EN ISO 13849-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.