Half of all motor bearing failures trace back to lubrication: too much grease overheats, too little scores the raceways, and the wrong type corrodes. This page covers grease selection, fill-quantity calculation, regreasing intervals and acceptance numbers so bearings reach their design life.
Use No. 2 or No. 3 lithium grease as standard, complex lithium or polyurea for hot environments, and a softer grade for high speeds. Fill quantity depends on speed: two-thirds of the free cavity below 1500 r/min, one-third to one-half at 3000 r/min, and never more than one-third above that. Estimate grams as 0.005 times outer diameter times width — about 3 to 5 g for a 6205. Overfilling chums the grease hot, while underfilling tears the film and gives a gritty hiss. Never mix thickener types; lithium and sodium bases react and liquefy.
Regrease on a speed-based schedule: roughly every 4000 hours at 1500 r/min and 2000 hours at 3000 r/min, halved in dusty plants. Clean the fitting first, pump fresh grease in while old grease exits the relief port in roughly equal volume, and on enclosed end shields open and clean them to remove caked residue. After regreasing run 30 minutes: temperature rise within 40 K and housing below 95 C is normal; anything hotter means too much grease or the wrong grade.
Read the failure signatures. Starved bearings shift from a smooth rush to a gritty hiss with climbing temperature and blued, dried-out raceways. Overfilled ones spike past 95 C right after regreasing, recover when cooled, and show churned, milky grease weeping from the shield. Wrong-grade grease discolours and separates within days of a change. Remedy: wash bearing and housing in kerosene or a proper cleaner, never blow residue into the raceways with compressed air, refill to spec, run in and verify. Replace any bearing showing discolouration, pitting or cage damage — grease will not save it.
| Item | Standard / value | Notes | If abnormal |
|---|---|---|---|
| Grease type | No. 2 or 3 lithium | Complex Li or polyurea for heat | Never mix thickeners |
| Fill at 1500 r/min | 2/3 of cavity | 6205 about 3-5 g | Estimate 0.005 times D times B |
| Fill at 3000 r/min | 1/3 to 1/2 of cavity | Over 1/3 at higher speeds | Overfill always overheats |
| Regrease interval | 4000 h at 1500 r/min | Halve at 3000 r/min | Halve again in dust |
| Post-regrease temp rise | ≤40 K | Housing ≤95 C | Check quantity and grade |
| Bearing limit temp | ≤120 C | Beyond this scrap it | Replace bearing |
| Run-in time | 30 min after regreasing | Watch the trend | Stop and inspect if hot |
| Replacement criteria | Discolouration, pitting, cage wear | Any one means replace | Do not limp on with grease |
Applies to rolling-bearing motors in routine upkeep. Log every regrease — date, grade, quantity — and record temperature rise weekly. When replacing bearings, check shaft and housing fits as well; a shaft worn 0.02 mm turns loose and a new bearing alone will not fix it.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rolling-bearing practice per GB/T 5226.1 (IEC 60204-1) and GB/T 275 fits; motor requirements per GB/T 755. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.