Selecting safety light curtain resolution and protective height

Two numbers decide whether a safety light curtain protects anyone: protective height that misses the opening, and resolution that lets a hand through. This page covers both, plus the safety distance calculation, with concrete values.

1. How it works

Resolution follows the risk: finger protection needs 14 mm, hand detection 30 mm, whole-body protection 40 mm or larger curtains or area scanners. Protective height depends on mounting: horizontal mounting at the edge of a hazard takes the hazard top plus the approach zone per the standard tables (typically 750-1000 mm by detection capability), while vertical mounting in front of an opening must cover the full opening height plus extension — a 900 mm opening needs at least 950 mm of curtain when reachable. Cascade up to two or three segments as the maker allows, and add the response times per the manufacturer table.

2. Numbers and practice

Safety distance per EN ISO 13855 for vertical installation: S = K × T + C, with K at 1600 mm/s for walking approach or 2000 mm/s for hand reach, T the sum of curtain response and machine stopping time (for example 15 ms plus 300 ms gives 315 ms), and C the intrusion distance — 100 mm for 14 mm resolution, 200 mm for 30 mm, zero for 40 mm and above under the whole-body algorithm. A worked case: 1600 × 0.315 plus 200 equals 704 mm, so fit at 750 mm or more. Horizontal mounting uses the standard tables, usually 850-1200 mm. Distances only ever grow during installation review — never shrink — and get re-measured after fitting.

3. Pitfalls and fixes

Selection follows five steps: risk assessment fixing the PL (PL d minimum for typical robot load stations, higher for presses), resolution by hand or body risk, protective height by opening, distance by K×T+C, and environment (IP65 or better with anti-mistripping design in dust and oil). Install with stable alignment, vibration-resistant brackets, no reflective objects or mirrors in the field of view, and correct earthing and shielding. Accept by beam-by-beam testing with a test rod, measured response time including machine stop, distance re-verification, reset and restart checks, and full inspection of any bypass (key switch plus time monitoring only). Repeat response and alignment tests every six months.

4. Light curtain selection quick reference

ParameterBasisTypical valueVerification
14 mm resolutionFinger protectionC = 100 mmRod test beam by beam
30 mm resolutionHand detectionC = 200 mmHand-shaped test piece
40 mm and aboveWhole bodyBody-entry algorithmDummy trial
Response time TCurtain plus machine stopMeasured sumCurtain tester
Safety distance SK×T+C1600 mm/s verticalTape measure re-check
Protective heightOpening plus extensionFull opening coveredBlock top and bottom
Cascade countMaker limitUsually 2-3 segmentsCheck maker table
Reset functionMonitored manual resetNo surprise restartReset test

5. Notes

For robot work zones, presses, shears and line openings. Five steps: risk assessment, resolution, protective height, safety distance, environment. Measure the response time with the machine stop included, never reduce the distance, and keep bypasses keyed, time-monitored and logged.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Positioning per GB/T 19876 (EN ISO 13855) and guards per GB/T 8196; electrical context per GB/T 5226.1; PL per GB/T 16855.1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Calculating the distance from the catalogue response time alone: machine stopping time is missing and the gap is short by exactly the part that matters; measure T as the sum
② Leaving reflective objects in front of the curtain: false trips breed tape-over-sensor workarounds; clear the field of view before installing
③ Bypass switches within casual reach: convenience becomes a permanent bypass and the safety function is fiction; key switch, time monitor and log, always

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.