Which range, what CAT rating, how many volts from the megger, why does the reading drift - the questions every electrician asks, answered one by one in field language.
Safety and selection first. CAT ratings describe transient withstand: CAT II for socket-level circuits, CAT III for distribution boards, CAT IV for the service entrance - board-level work needs at least CAT III 600V. Megger voltage: 500V for 380/220V equipment, 1000V for high-voltage motors, and never into drives or PLC electronics. Clamp meters: transformer-jaw types read AC only, DC current needs a Hall-effect jaw marked DC A.
Operation and readings. A terminal voltage that collapses under load points to source impedance or a loose joint - the open-circuit reading is the EMF, the loaded one is the truth, so chase the volt-drop along the circuit. The continuity beeper fires below roughly 30~50 ohms, so a corroded joint can still beep - judge by the resistance value itself. Discharge cables before and after insulation tests; capacitance holds charge that bites. A basic digital meter lies on inverter output because of PWM, so use true-RMS. Two meters disagreeing by a couple of volts usually means accuracy class and battery state, not a faulty circuit - and never touch the metal tips when measuring high resistance, your body parallel-reads low.
| Question | Short answer | Key point | Risk note |
|---|---|---|---|
| Which CAT rating | CAT III 600V for boards | CAT II stops at sockets | Underrated meters explode on transients |
| Megger voltage | 500V for LV equipment | 1000V for HV motors | Never into electronics |
| Clamp meter for DC | Hall-effect type only | Transformer jaws read AC | Look for the DC A marking |
| Voltage collapses under load | Source impedance or loose joint | Trace the volt-drop | Not a meter fault |
| Hands on tips at high ohms | Body reads in parallel | Keep off metal tips | Biggest error on high resistance |
Print this for the training board. The governing rules: check range and CAT before every measurement, ohms only when dead, discharge after megger tests, doubt settings and batteries before doubting the circuit, and send instruments for annual calibration.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Instrument safety per GB/T 4793.1 (IEC 61010-1), digital multimeter specification per GB/T 13978, insulation testing practice per GB 50150. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.