Damaged slot insulation starts as elevated leakage and ends as burned windings through interturn shorts. This page covers how slot insulation fails, megger and surge-test procedures with acceptance numbers, and how to tell moisture from a genuine breakdown.
Slot insulation in DMD or paper laminates fails mostly at three spots: the slot mouth, where insertion damage and electromagnetic vibration wear it through; at core tooth tips where burrs puncture the film; and at end windings whose loose bindings rub under starting torque. Moisture, oil and dust lower resistance superficially and recover after cleaning, whereas real breakdown shows as a stable low or zero earth reading, hot spots from interturn shorts, and phase current unbalance beyond 10 percent. An absorption ratio under 1.3 signals aged insulation.
Megger procedure: lock out, open every link in the terminal box, and discharge for at least a minute. Use 500 V test voltage for motors below 500 V and 1000 V or 2500 V for high-voltage machines. Measure each phase to earth and phase to phase; hot resistance must exceed 1 megohm per kV, cold readings should be above 5 megohms, and anything under 0.5 megohm must not be energised. Take R15 and R60 readings for an absorption ratio above 1.3. Always disconnect VFDs, soft starters and encoders first, or the surge destroys the electronics.
Passing the earth test does not clear interturn faults. A surge comparison tester applies identical impulses to both ends of each phase; coincident traces are healthy, while trace-area differences or resonant shifts beyond 5 percent indicate shorted turns. Field checks: DC resistance unbalance under 2 percent, and a 10-minute no-load run followed by feeling the tooth tips — the hot tooth marks the short. Damp machines show low resistance with a normal absorption ratio and recover past 5 megohms after 8 hours at 60 to 80 C; those that do not are genuinely punctured.
| Test | Instrument | Acceptance | If failed |
|---|---|---|---|
| Cold insulation to earth | 500 V megger | ≥5 MΩ (380 V motor) | Dry and retest |
| Hot insulation to earth | 500 V megger | ≥1 MΩ per kV | Stop and repair |
| Absorption ratio R60/R15 | Megger | ≥1.3 | Dry and verify |
| Phase-to-phase insulation | 500 V megger | ≥5 MΩ | Split at terminal box |
| DC resistance unbalance | Kelvin bridge | ≤2 percent | Surge-test suspect phase |
| Surge wave comparison | Surge tester | Traces coincide | Over 5 percent means shorted turns |
| No-load current balance | Clamp meter | ≤10 percent | Check turns and air gap |
| Local temperature rise | Spot pyrometer | Tooth temp spread ≤10 K | Hot tooth marks the fault |
Applies to 380 V and 660 V low-voltage induction and servo stators. Test after overhauls, after wetting and after trips, and log readings to trend insulation health. Discharge, disconnect, verify dead — in that order, every time.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Insulation testing per IEC 60034-27; machine electrical safety per GB/T 5226.1; motor basics per GB/T 755 and GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.