A hot motor is not automatically a failing motor. Insulation class, bearing limits and the gap between surface and winding temperature give you the baseline before you condemn anything.
The insulation class on the nameplate sets the limit: class B 130C, class F 155C, class H 180C per IEC 60034-1 (GB/T 755). What is judged is the winding temperature rise, not the absolute temperature - a class F machine at 40C ambient allows about 105K by the resistance method. A frame that burns the hand after one second (roughly 60~70C) can be perfectly normal at full load, so trends beat absolute numbers.
Separate the two measuring points. Track winding health by aiming an infrared gun at the core and end shields and comparing with history - 15C above the same-season baseline warrants investigation. Bearing housing above 80C deserves attention and above 95C means stop and inspect grease and clearance. Before condemning the motor, rule out the cheap causes: nameplate current exceeded, fan cowl blocked by lint, fins packed with dust - a Y132 frame can gain 20C within half an hour from a plastic bag over the cowl. On drives, below 20Hz the shaft fan barely cools, so fit a separate forced-air fan for long low-speed running.
| Point | Normal | Alarm | Action |
|---|---|---|---|
| Winding, class F, 40C ambient | Rise below 85K | Rise near 105K | Check load and cooling |
| Bearing housing | Below 70C | 80C watch, 95C stop | Grease and clearance check |
| Frame at full load | 60~80C common | 15C above history | Compare with twin machine |
| Fan cowl and fins | Clean | Blocked with lint | Stop, clean, retest |
| Low-speed inverter duty | Slightly higher rise | Full load below 20Hz | Add forced-air fan |
Always log load current next to temperature. A hot motor with normal current points to cooling; a hot motor with over-nameplate current points to load. Temperature is the symptom, not the diagnosis.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine temperature limits per GB/T 755 (IEC 60034-1), small motors per GB/T 12350, machinery safety per IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.