When line sections run at mismatched speeds the product piles up or stretches, so synchronisation is the skeleton of any conveying line. This page compares speed-chain, ratio-lock and master-follower schemes and gives the tuning sequence.
Speed-chain: one master setpoint feeds every section through fixed ratio factors, ideal for continuous lines with a fixed process ratio such as paint or drying lines. Ratio-lock: sections hold independent setpoints locked by ratio, allowing one section a process trim while the rest follow, fitting lines with per-section process differences. Master-follower: the follower tracks the master actual speed or load, for mechanically coupled shafts and gear-linked drives. Choose by coupling strength: rigid mechanical links take master-follower, loose process coupling takes the speed chain.
Tune in order: first get each section accurate standalone, from plus or minus 1~3 percent on V/F up to 0.1 percent with encoder closed loop if needed; then run the line empty, drop markers at each transfer and adjust ratios until spacing stays constant end to end; finally run loaded for two hours watching differential creep. Correct residual mismatch with a dancer or tension sensor feeding a trim into the downstream section, or without sensors, read currents: a downstream section drawing clearly less current is stretching product, so nudge its ratio 1~2 percent at a time. Common failures are start-up surges from unequal inertia, poor tracking below 10Hz on V/F, and stall of one section while the rest keep running, which needs a jam interlock.
| Scheme | Coupling fit | Setpoint method | Accuracy | Tuning effort |
|---|---|---|---|---|
| Speed chain | Weak, continuous lines | Master times ratio | ±1~3 percent | Low |
| Ratio lock | Per-section process trims | Independent, ratio-bound | ±1~3 percent | Medium |
| Master-follower | Rigid mechanical links | Track master actual | ±0.5~0.1 percent | Medium-high |
| Encoder closed loop | High precision demands | Closed speed loop | ±0.1 percent | High |
| Fieldbus synchronisation | High-end lines | Bus clock sync | Very high | High |
The core is three passes: each drive accurate alone, the line aligned empty, then proven loaded. Never align the line before the units are individually accurate, and archive every ratio and ramp so a replacement drive can be restored from records rather than memory.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Interlocks and electrical safety per IEC 60204-1 / GB/T 5226.1, drive system performance per IEC 61800-2. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.