Adding microsteps at the first lost step is a myth; microstepping cannot raise the torque ceiling. This page ranks the real causes of lost steps and clarifies the indirect link to microstepping.
Microstepping reshapes the current from a 0-to-full jump into 32 gradual levels: vibration and noise drop, low-speed smoothness rises, and nominal resolution refines. It adds no torque; a load the full step cannot move will not move at 256 microsteps either. The indirect benefit is real though: since vibration itself provokes stalls, reducing vibration reduces that share of lost steps, but it never cures torque-shortfall stalls.
Rank the real causes: first, acceleration too fast, the pulse rate outclimbing torque capability, over half of cases; second, the duty point outside the torque-speed curve; third, dwelling in the resonance band at specific low speeds; fourth, thermal derating, clustered in hot hours; fifth, current set too low; sixth, low supply voltage at speed. Microstepping does not make the list. Diagnose by pattern: loss concentrated in ramps, fixed at a speed, or fixed at a time of day.
Set microsteps at 8 to 16, the value zone where smoothness and noise are already adequate; beyond 32 the gains taper and doubled pulse rates burden the host. Keep the microstep and command scale consistent, changing both together. Lock microstepping while hunting lost steps: fix the ramp and duty point first, touch microstepping last.
| Cause | Signature | Fix |
|---|---|---|
| Acceleration too fast | Loss in ramps | Widen ramps 20 to 50 percent |
| Speed beyond curve | Loss at fixed high speed | Slow down or upsize motor |
| Resonance dwell | Jitter at fixed low speed | Microstep and sweep through |
| Drive overheating | Batch loss in hot hours | Retrofit cooling |
| Current too low | Stall under load | Raise to 80 percent of rating |
| Microstep mismatch | Systematic size error | Match scale and verify travel |
Keep a lost-step log with time, speed and load state; ten entries usually pin the cause. Write the microstep-to-scale mapping into program comments; any change requires a scale update and travel verification.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor and drive safety follow GB/T 12350 and IEC 60034; machine electrical safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.