Matching servo mode selection with the host controller

When the controller output and the drive input do not match, oscillation or lost pulses follow. This page explains how control mode pairs with the host interface, how to choose pulse, bus or analogue hardware, and the commissioning sequence.

1. How it works

Pulse links use PLC transistor outputs, usually capped near 100 kpps, with no real-time synchronisation because of the scan cycle; they suit simple single-axis positioning. Bus links such as EtherCAT run 500 µs or even 125 µs cycles with distributed clock sync below 1 µs, which multi-axis interpolation requires. Analogue links give plus-minus 10 V speed or torque commands: simple but noise sensitive. Fix the host capability first, then derive the drive mode.

2. Practice and pitfalls

Match three things on pulse interfaces: level (5 V differential versus 24 V single-ended), minimum pulse width (commonly 2.5 µs at the drive) and multiplication factor. Single-ended 24 V tolerates noise poorly; runs beyond 10 m should go differential. For bus interfaces install the drive device description in the PLC project before scanning the network. Verify with 100 back-and-forth cycles per axis, a test circle for interpolation roundness, and gantry sync deviation alarms.

3. Host controller and servo interface quick table

ItemPulse controlBus controlAnalogue control
Real-time behaviourLimited by scan cycleCycle within 500 µsFast but unsynchronised
Typical frequencyUp to 100 kppsMatched to cycleBandwidth within 1 kHz
Multi-axis syncHard to guaranteeError below 1 µsNot suitable
Wiring per axis3 to 5 wiresOne network cable2 to 4 wires
DiagnosticsIO levels onlyFull parametersSetpoint only
Suitable axes1 to 48 or more1 to 2

4. Notes

List axis count, synchronisation and cycle time at design stage; above four axes or with interpolation, go straight to a bus. Keep per-axis command scale, gear ratio and direction checks in the commissioning record.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 5226.1 for industrial machinery electrical requirements; real-time Ethernet profiles follow IEC 61784. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Forgetting the gearbox ratio in the command scale makes a 100 mm move stop 2 mm short and drift worse over time
② Scanning a bus network without the device description file causes random packet faults that are nearly impossible to trace
③ Sending 24 V single-ended pulses over 10 m or more distorts edges and loses pulses; use 5 V differential for long runs

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.