Electronic gear ratio setting ranges and limits

Electronic gear ratios have upper and lower limits set by firmware word length. Exceed them and you get rejected parameters, silent truncation, or crawling low-speed motion. This page explains typical ranges, consequences and practical choices.

1. How it works

The ratio is bounded by firmware arithmetic: a common range is 1/9 to 262144, though older drives cap at 32767. Out-of-range values are either refused with an alarm or silently truncated, introducing position error. Check the parameter range in the manual before calculating. The lower limit of 1/9 means command frequency can only be divided up to nine times; beyond that the motor crawls at low speed.

2. Practice and pitfalls

Two failure patterns: a numerator above the limit gets rejected, and workarounds that divide a large number by the denominator lose precision through truncation, showing up as 0.2 mm error over 500 mm. Ratios below the limit push the scaled command frequency into the unstable low-speed region, doubling positioning time. Keep numerator and denominator coprime and within four digits, and keep the command frequency below 70 percent of the host output capability.

3. Electronic gear range quick table

ItemTypical rangeConsequence if exceeded
Ratio upper limit262144 (older: 32767)Rejected or alarm
Ratio lower limit1/9Low-speed crawling
After reductionBoth terms within four digitsAvoids truncation error
Command scale0.001 to 0.01 mmToo fine loses pulses, too coarse steps
Frequency marginBelow 70 percent of host outputLost pulses when marginal
Accuracy checkError within one countOversize points to lead error

4. Notes

Calculate and range-check the ratio during design and record it in the electrical scheme. During commissioning measure one full revolution with a dial gauge; error must stay within one command count.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Parameter range practice follows GB/T 5226.1; adjustable-speed electrical systems reference the IEC 61800 series. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Bypassing a rejected ratio by dividing a large denominator truncates precision, producing 0.2 mm error over 500 mm
② Forcing a ratio below the lower limit puts the command frequency into the crawling region and doubles positioning time
③ An overly fine scale outruns the host pulse output, losing pulses that grow with speed; keep a 30 percent margin

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.