Position, speed and torque modes each solve a different problem, and picking the wrong one makes tuning painful or causes oscillation. This page explains the control-loop differences, where each mode fits, and how to switch modes safely.
In position mode the drive closes the position loop using pulses or a bus command from the controller, giving the best accuracy for dispensing, feeding and cam applications. Speed mode regulates rotational speed from an analogue or bus setpoint and suits rollers and fans where absolute position does not matter. Torque mode drives the current loop directly for the fastest response, used in tension, pressing and winding.
A simple rule: choose position for accuracy, speed for stability, torque for force. Typical tension control uses torque mode with a speed limit, so the motor applies constant torque while the web sets the speed. Multi-axis interpolation and gantry synchronisation demand bus-based position mode; pulse trains lose steps at high frequency. Mode changes must be done with the drive switching function, never by rewiring live.
| Item | Position mode | Speed mode | Torque mode |
|---|---|---|---|
| Outer loop | Position loop | Speed loop | Current loop |
| Command source | Pulse or bus command | Analogue or bus | Analogue or bus |
| Typical accuracy | Within 1 pulse | Ripple below 0.5 percent | Torque error within 5 percent |
| Typical uses | Indexing, interpolation | Feed rollers, fans | Tension, pressing, winding |
| Main risk | Lost pulses, oscillation | Runaway on broken setpoint | Overspeed without load |
| Required companion | Electronic gear plus limits | Zero-speed clamp | Speed limit parameter |
Fix the control mode at design review and record it in the scheme, so wiring is not reworked on site. Commissioning order: verify mode and command direction unloaded, tune with load, then enable interlocks and limits.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 5226.1 for control functions and safety requirements; programmable device interfaces follow the IEC 61131 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.