When the machine rings after a batch change, the load shifted and the gains did not follow. This page explains adaptive gain, parameter-set switching, and how to handle sudden load steps.
Modern drives estimate load inertia continuously and scale speed and position gains accordingly, typically within a few hundred milliseconds. Adaptation covers gradual changes such as winding diameter or material batches. Sudden steps, like a gripper picking and dropping a part, exceed the adaptation bandwidth and still oscillate; handle those with parameter-set switching: one gain set for light load, one for heavy, switched by the PLC at the grasp event.
Tune both load cases separately, store each gain set, and define the switching trigger and its timing. Switch at zero speed or in the dwell window; switching mid-motion shocks the mechanics, so allow 50 to 100 ms transition afterwards. Drives such as the A6 provide a gain-switching input, faster than a software switch. Verify with 200 pick-and-place cycles and zero oscillation alarms.
| Scenario | Recommended action | Acceptance |
|---|---|---|
| Gradual load change | Enable real-time adaptation | No oscillation alarm throughout |
| Sudden load step | Switch parameter sets | Zero alarms in 200 cycles |
| Switching moment | At zero speed or dwell | Never switch mid-motion |
| Transition after switch | 50 to 100 ms delay | No impact or noise |
| Backlash-heavy mechanics | Fix mechanics before adapting | Identification drift under 10 percent |
| Emergency measure | Lower stiffness, soften ramps | Ring disappears as criterion |
Record the switching condition and signal source of both gain sets in the tuning report and in program comments. During monthly maintenance check identification drift; above 15 percent, inspect backlash and couplings first.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo control requirements follow GB/T 5226.1; adjustable-speed drive performance references the IEC 61800 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.