A wrong A6 electronic gear ratio is why moves miss their target by a few tenths of a millimetre. This page explains the Pr0.09 and Pr0.10 arithmetic, the 23-bit encoder conversion, and overflow traps.
The A6 encoder is a 23-bit absolute type giving 8388608 counts per revolution. The gear numerator Pr0.09 and denominator Pr0.10 accept ratios from 1/9 up to 262144. Compute numerator over denominator as encoder counts per revolution divided by command pulses per revolution, adjusted for the gearbox. With a 5 mm lead screw and 10000 command pulses per revolution, the ratio is 8388608 to 10000; reduce it to lowest terms before writing. Settings take effect after a power cycle.
Verify by commanding exactly 10000 pulses and measuring travel; error beyond one count means the lead or reduction ratio is wrong. Beware mixing command units: if the host sends 10000 in 0.001 mm units that is 10 mm, not 10000 pulses per revolution. Overly large denominators can be truncated in 32-bit arithmetic, losing counts over long strokes; always use the reduced ratio. After any gear change, re-home the axis.
| Parameter or item | Value or action | Note |
|---|---|---|
| Pr0.09 | Gear numerator | Reduce with denominator |
| Pr0.10 | Gear denominator | Range 1 to 262144 |
| Encoder resolution | 8388608 counts per rev | 23-bit absolute |
| Effective condition | Power cycle required | Live edits ignored |
| Verification | Command 10000 pulses, measure | Error under one count |
| After any change | Re-home the axis | Reference drifts otherwise |
Write the gear ratio formula and reduced result into program comments and the commissioning record. After every change: jog slowly to check direction and scale, re-home, and only then allow automatic operation.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Drive parameter practice follows GB/T 5226.1; numerical control interfaces reference the IEC 61131 series. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.