A linear motor drives the load directly, so the linear scale is its eye. This page covers the loop architecture, scale selection and mounting, gain tuning and thermal compensation down to micrometres.
The motor feedback rides on the magnet track and cannot see slide deflection, guideway error or thermal growth; only a scale mounted on the slide closes the loop where the workpiece lives. With 1 micrometre or finer resolution and the high bandwidth of direct drive, speed loops above 1 kHz, full-stroke accuracy reaches plus-minus 3 µm. A linear motor system without a scale is blind, with accuracy resting entirely on machining.
Scale selection: resolution at half the accuracy target (0.5 µm for plus-minus 3 µm), accuracy grade per metre (grade A plus-minus 3 µm/m), and speed headroom above 5 m/s since linear motors easily reach 3 to 5 m/s. Mounting: base flatness 0.01 mm/m, parallel to the guideway within 0.02 mm/m, reading head gap typically 0.8 mm. Absolute scales skip homing; incremental ones need a home switch. Aluminium bases grow 23 µm per metre per degree, so precision work uses glass scales or a compensation table.
Tuning: speed loop bandwidth 300 to 500 Hz raised from 100 Hz until just short of ringing, position loop 50 to 100 Hz. The Stribeck friction of the guides causes low-speed stick-slip, cured with friction feedforward. Cogging creates periodic speed ripple at the magnetic pole frequency; notch it accordingly. Acceptance uses a laser interferometer over full stroke with a five-segment linear compensation table.
| Element | Recommended | Note |
|---|---|---|
| Scale resolution | Half of accuracy target | 0.5 µm for ±3 µm |
| Scale accuracy grade | ±3 µm/m, grade A | Longer strokes demand more |
| Head gap | 0.8 mm typical | Verify over full stroke |
| Speed loop bandwidth | 300 to 500 Hz | Raise from 100 Hz |
| Position loop bandwidth | 50 to 100 Hz | Higher excites resonance |
| Thermal growth | 23 µm/m per degree on aluminium | Glass scales for precision |
Acceptance demands a laser interferometer; dial gauges cannot see 3 µm truth. Archive the full-stroke error curve so later degradation can be attributed to the scale or the guides by comparison.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Position detection practice references GB/T 5226.1 and IEC 61491 digital interfaces; linear motors reference IEC 60034. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.