An inaccurate inertia ratio makes auto-tuning and stiffness levels useless. This page covers how to compute and identify the ratio, what happens when it is wrong, and typical ranges per transmission type.
Inertia ratio equals load inertia reflected to the motor shaft divided by rotor inertia. Reflection multiplies by the square of the reduction ratio: for a direct ball screw use J = m times P squared over four pi squared with lead P in metres; for pulleys use J = m times r squared times i squared. Typical ranges: direct ball screw 3 to 10, belt drive 5 to 15, arm structures 10 to 30; above 30 add a gearbox. The entered value sets the auto-tuning starting point.
Identify by calculation from drawings (about 20 percent error, conservative) or by the drive identification routine (about 10 percent error, provided the mechanics are sound). Release the brake first, and let the motor rotate freely for several cycles. If identification differs from theory by more than 30 percent, check for coupling slip or a wrong reduction ratio before doubting the routine. Too small a ratio yields high-speed ringing; too large yields sluggish response.
| Transmission | Inertia ratio range | Tuning note |
|---|---|---|
| Direct ball screw | 3 to 10 | High stiffness acceptable |
| Belt drive | 5 to 15 | Watch belt elasticity oscillation |
| After gearbox | 1 to 5 | Reflected inertia drops sharply |
| Arm structure | 10 to 30 | Segment moves to limit overshoot |
| Above 30 | Add a gearbox | Gain ceiling otherwise too low |
| After load change | Re-identify | Update beyond 30 percent deviation |
Estimate the inertia ratio from mechanical drawings at design stage; above 30, put a gearbox in the scheme instead of hoping tuning will fix it. Keep theory, identification and final values in the report for future load changes.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo tuning follows GB/T 5226.1; motor inertia and performance data reference IEC 60034. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.