Incremental versus absolute encoders: what actually differs

Whether the position survives a power cut is the dividing line between incremental and absolute encoders. This page compares principle, data format, battery care and selection criteria in practical terms.

1. How it works

Incremental encoders output A, B and Z pulses and report only change, so the position is lost at power-off and the axis must be re-homed. Absolute encoders encode position directly, typically 23-bit single-turn with 8388608 counts, with multi-turn models tracking revolutions via battery or power-off memory. Absolute types cost roughly 30 to 100 percent more but eliminate homing time, which pays back quickly on cycle-critical machines.

2. Numbers and practice

The absolute encoder lives or dies by its battery: lithium cells last 4 to 10 years, alarms typically trigger near 3.0 V, and you should order spares once the reading drops below 3.1 V. Replace the battery with the drive powered up; swapping it with power off wipes the memory. Incremental types need no battery but depend on the Z-phase reference, so loose couplings or bumped stops shift the datum; verify homing repeaterability quarterly and fix mechanics when error exceeds one count.

3. Pitfalls and fixes

Selection in three questions: must position survive power loss, is homing time acceptable, must multi-turn travel be tracked? Injection moulding clamps, machine axes and stacker cranes need absolute; continuous uni-directional conveyors run fine and cheap on incremental.

4. Incremental versus absolute quick table

AspectIncrementalAbsolute
Position after power-offLost, re-home neededKept by battery
Data formatA/B/Z pulsesSerial or bus code
Single-turn resolutionCommonly 2500 lines23-bit, 8388608 counts
Maintenance focusHoming repeatabilityBattery voltage and life
Relative costLow30 to 100 percent higher
Typical usesContinuous conveyorsMoulding, machine axes

5. Notes

When retrofitting, confirm the original encoder type first; mixing types confuses both the host program and battery management. Hand over battery replacement records with absolute machines; with no record, treat the battery as end-of-life and replace it immediately.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Encoder classification and performance follow IEC 61146 and related standards; machine safety wiring aligns with GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Replacing the absolute battery with the drive powered down wipes stored position and defeats the purpose
② Ignoring a battery reading below 3.1 V invites a sudden alarm and an unplanned line stop
③ A loose reference block shifts incremental homing and drifts product dimensions; verify quarterly

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.