Whether the position survives a power cut is the dividing line between incremental and absolute encoders. This page compares principle, data format, battery care and selection criteria in practical terms.
Incremental encoders output A, B and Z pulses and report only change, so the position is lost at power-off and the axis must be re-homed. Absolute encoders encode position directly, typically 23-bit single-turn with 8388608 counts, with multi-turn models tracking revolutions via battery or power-off memory. Absolute types cost roughly 30 to 100 percent more but eliminate homing time, which pays back quickly on cycle-critical machines.
The absolute encoder lives or dies by its battery: lithium cells last 4 to 10 years, alarms typically trigger near 3.0 V, and you should order spares once the reading drops below 3.1 V. Replace the battery with the drive powered up; swapping it with power off wipes the memory. Incremental types need no battery but depend on the Z-phase reference, so loose couplings or bumped stops shift the datum; verify homing repeaterability quarterly and fix mechanics when error exceeds one count.
Selection in three questions: must position survive power loss, is homing time acceptable, must multi-turn travel be tracked? Injection moulding clamps, machine axes and stacker cranes need absolute; continuous uni-directional conveyors run fine and cheap on incremental.
| Aspect | Incremental | Absolute |
|---|---|---|
| Position after power-off | Lost, re-home needed | Kept by battery |
| Data format | A/B/Z pulses | Serial or bus code |
| Single-turn resolution | Commonly 2500 lines | 23-bit, 8388608 counts |
| Maintenance focus | Homing repeatability | Battery voltage and life |
| Relative cost | Low | 30 to 100 percent higher |
| Typical uses | Continuous conveyors | Moulding, machine axes |
When retrofitting, confirm the original encoder type first; mixing types confuses both the host program and battery management. Hand over battery replacement records with absolute machines; with no record, treat the battery as end-of-life and replace it immediately.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Encoder classification and performance follow IEC 61146 and related standards; machine safety wiring aligns with GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.