A servo achieves millisecond response and drift-free positioning through three nested closed loops, a control depth entirely different from a VFD spinning a motor open loop. This page covers the four building blocks, how the loops interlock, and how to match inertia during sizing.
The system has four parts: the drive, power conversion plus the three-loop computation; the motor, low inertia with 3~5 times overload margin and high demagnetisation temperature; the encoder, 2500-line incremental or 17~23 bit absolute, feeding back position and speed; and the motion controller, a PLC motion module, a dedicated motion controller or a CNC. The essential difference from a VFD is the feedback: a V/F drive runs without any encoder, while a servo is dead without one, since both speed and position come from it. Size the motor on three checks: inertia ratio, load over rotor, at or below 10 for general duty and 5 for high-speed precision; speed and torque demand; and overload, with acceleration torque up to three times rated checked against the RMS torque over the cycle.
From inside out: the current loop is the fastest at 1~2kHz bandwidth and turns torque, factory-set and not user-touched; the speed loop runs at several hundred Hz, receives the speed command and outputs the torque command, and this is where the user tunes stiffness; the position loop is outermost, at a third to a fifth of the speed-loop bandwidth, and outputs the speed command. The interlock rule is that each inner loop must be an order of magnitude faster than the one around it, or raising outer gain oscillates. Tune in the same order: current first, factory-set, then speed stiffness upward until slight oscillation and back off 30 percent, then position gain and the feedforward terms. Velocity and torque feedforward are the tools against following error and are mandatory for high-precision interpolation.
Inertia mismatch is the number one sizing trap: at a 20-to-1 ratio the speed loop oscillates no matter how it is tuned, seen as hunting around the target. A bigger frame or a gearbox, which divides the reflected inertia by the square of the ratio, both fix it. Compute torque in three steps: acceleration from T_a = 2π·J_total·n/(60·t_acc), constant-speed from the load, and RMS over the cycle not exceeding rated. Resolution is set jointly by encoder and mechanics: a 23-bit encoder with a 10mm pitch screw resolves 1.2nm on paper, but backlash and compliance keep the real figure at 1~5μm, so every axis needs backlash and pitch error compensation.
| Item | Servo system | VFD | Why different | Selection hint |
|---|---|---|---|---|
| Control scheme | Three closed loops | V/F or vector | Servo requires feedback | Positioning picks servo |
| Overload factor | 3~5 times | 1.2~1.5 times | Motor design margin | Shock loads check this |
| Low-speed smoothness | Range 1:5000 plus | 1:20 to 1:100 | Weak vector torque at low speed | Slow feeds pick servo |
| Response bandwidth | Hundreds of Hz speed loop | A few to tens of Hz | Inertia and feedback | Fast reciprocation picks servo |
| Power range | 50W~55kW common | 0.4kW to MW | Servos uneconomic large | High power picks VFD |
| Cost, same power | 2~4 times | Baseline | Feedback and control depth | Invest by need |
The tuning order is fixed: mechanics first, coupling tight and backlash removed; current loop factory-set; then speed stiffness; then position gain and feedforward. Back up every servo parameter set, because importing it into a replacement drive halves the commissioning time.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servos per GB/T 16439; equipment safety per GB/T 5226.1 / IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.