Sizing by procedure beats guessing by two frames. This page walks five steps: load torque, reflected inertia, speed, initial selection and accel checks, with a pass criterion for each.
Step one, load torque: reflect gravity, friction and cutting force to the motor shaft; for screws use T = F times P over two pi eta with lead P and efficiency about 0.9. Step two, reflected inertia, judged by ratio: direct drive under 10, under 5 after a gearbox. Step three, speed: convert maximum line speed to rpm with 20 percent headroom below rated. Step four, shortlist by rated torque above load torque and a rotor inertia meeting the ratio. Step five, accel check: acceleration plus load torque within 80 percent of peak torque.
Working numbers: sliding guides run a friction coefficient of 0.05 to 0.15, linear guides 0.003 to 0.01, plus 5 to 10 percent of load weight for seals. Vertical axes need holding torque at 1.2 times gravity torque and a brake. Speed conversion for screws: n = 60 times v over P with v in mm/s and P in mm. RMS torque over the duty cycle should stay under 80 percent of rated; beyond that, improve cooling or upsize.
Classic mistakes: sizing on rated torque alone and tripping on the acceleration limit; guessing the inertia ratio and oscillating or crawling on install; forgetting the brake on vertical axes and letting the load fall on power loss; running at rated speed with no margin and shortening life. The sizing report lists five numbers with criteria: load torque, inertia ratio, top speed, accel torque and RMS torque.
| Step | Compute | Pass criterion |
|---|---|---|
| Load torque | Gravity, friction, cutting | Below rated torque |
| Reflected inertia | To motor shaft | Ratio under 10 direct, 5 geared |
| Top speed | From line speed | Within 80 percent of rated |
| Accel torque | Inertia times rate | With load within 80 percent of peak |
| RMS torque | Over duty cycle | Below 80 percent of rated |
| Vertical axis extra | Holding and brake | 1.2 times gravity, braked |
Before ordering, cross-check the inertia ratio and accel torque against the drive allowances for that power frame. Within the same flange, prefer the higher-inertia rotor for steadier dynamics; it saves tuning grief later.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor duty and safety follow GB/T 12350 and IEC 60034-1 ratings; overall machine electrical safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.