Hydraulic power unit structure and composition

A hydraulic unit lives or dies by oil temperature and cleanliness. This page covers the tank, pump group, valve block, auxiliaries and cooling, with working parameters.

1. How it works

Tank: 3 to 5 times pump flow for low pressure, 5 to 7 for high, with separated suction and return zones, a sloped bottom, level and temperature gauges. Pumps: gear pumps cheap and dirt tolerant below 16 MPa, vane pumps quieter for 7 to 21 MPa, piston pumps for 25 to 40 MPa, with motor power at 1.2 times pump demand. Valves: relief for pressure, directional for flow path, throttles for speed, counterbalance against falling, mounted on manifold blocks. Auxiliaries: filters, suction 100 µm, return 10 to 25 µm, pressure 5 to 10 µm, accumulators, gauges. Cooling holds oil at 40 plus-minus 5 degrees C.

2. Numbers and practice

Key numbers: machine auxiliaries 5 to 10 MPa, press main drives 25 to 32, injection moulding 14 to 17. Pump flow is 1.1 times peak actuator demand. Oil: L-HM46 anti-wear, or L-HM32 below 10 degrees ambient; the viscosity window is 15 to 400 mm²/s with the sweet spot near 40 degrees. Filtration: 5 µm for servo valves, 10 for proportional, 25 for plain; servo circuits want cleanliness NAS class 7 or better.

3. Pitfalls and fixes

Oil temperature is the vital sign: 40 to 50 degrees ideal, above 60 halves oil life by oxidation, below 15 the pump cavitates. Relief losses dominate heating, so set pressure as low as the work allows. Oil changes every 2000 to 4000 hours or by contamination, filters on differential-pressure alarm, oil samples half-yearly. Acceptance: 2 hours unloaded run-in plus 1 hour loaded, noise at or below 75 dB one metre from the pump, oil under 55 degrees after an hour at full load, no weeps.

4. Hydraulic unit quick table

SectionKey parameterSelection note
Tank3 to 7 times pump flowSeparate suction and return
Pump group7 to 40 MPa by typeGear, vane or piston
Valve blockManifold mountedRelief, direction, throttle, balance
FiltersThree stages5 µm for servo valves
AccumulatorPeak or hold-basedBladder type common
CoolerOil at 40 plus-minus 5 degreesAbove 60 halves oil life

5. Notes

Read the schematic along the energy path: tank to pump to valves to actuators and back, with pressure grades and oil type marked. Keep an oil ledger of changes, sample data and filter swaps; contamination trends are the health report.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Hydraulic systems reference GB/T 3766 (identical to ISO 4413) together with GB/T 5226.1; viscosity grades follow GB/T 3141. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Setting system pressure higher than needed makes relief losses the main heater and halves oil life
② Servo valves without 5 µm filtration jam constantly; one valve costs more than a tank of oil
③ Loading a cold system in winter cavitates the pump; warm up unloaded first

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.