Servo gain tuning methods and step-by-step procedure

Tuning gains in random order ends in oscillation. This page explains the current, speed and position loop tuning sequence, the hand-feel criteria, and how to use auto-tuning properly.

1. How it works

The current loop is factory tuned and normally untouched. For the speed loop, enter the inertia ratio first, start proportional gain at half the default, raise until slight oscillation, then back off 20 percent; add integral action of 20 to 100 ms to remove steady-state error. The position gain is set to roughly one third to one half of the speed-loop bandwidth; higher values cause overshoot and buzzing. A firm but slightly springy feel when pushing the mechanism is correct; mushy means low gain, hissing means high gain.

2. Practice and pitfalls

Auto-tuning is not a magic key: wrong inertia input ruins the result. Measure the inertia ratio with the drive identification function, enter it, run auto-tuning, then fine-tune manually. Auto results are conservative; for fast cycles raise the stiffness level 20 to 30 percent and re-verify. Stiffness levels, such as 1 to 81 on A6 drives, package the gains: step three to five levels at a time and back off when it rings.

3. Servo gain tuning sequence table

StepTargetCriterion
Step 1Measure and enter inertia ratioIdentification error under 10 percent
Step 2Speed loop KpBack off 20 percent after oscillation
Step 3Speed loop integralSteady-state error gone, no overshoot
Step 4Position loop KpOvershoot within one count
Step 5Loaded step testDip under 3 percent
Step 6Long-run confirmation30 minutes without alarm

4. Notes

Record the identified inertia, the final parameter set and acceptance data in the tuning report, and back up parameters to the drive. When the mechanism changes, rerun the procedure; never reuse old parameters directly.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo commissioning follows GB/T 5226.1; AC servo drive performance references IEC 61800-5-1 and IEC 60034. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Running auto-tuning without a real inertia ratio corrupts the result; identify and enter it first
② Pushing position gain past half the speed-loop bandwidth causes overshoot and buzzing, and distorted interpolation when bandwidths differ
③ Not logging tuning steps leaves you unable to roll back after oscillation, forcing a factory reset

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.