Four, six or eight leads are just different winding terminations. This page explains how to identify them, the current settings for series and parallel, and what miswiring does.
Four leads: two windings, bipolar drive only, full windings engaged, best torque utilisation. Six leads: centre taps on both windings; usable unipolar or bipolar, but bipolar use leaves the tap floating and only half the winding works at half current. Eight leads: four independent windings, the flexible one; series gives more torque at lower current (0.7 of rated), parallel gives better speed at 1.4 times rated current. Identify with a meter: same-winding resistance is lowest, a centre tap reads half of that to each end.
Current settings for an 8-lead motor rated 4 A: series at about 2.8 A (times 0.7), parallel at about 5.6 A (times 1.4). Reversed, series at 4 A doubles winding current and cooks the motor in ten minutes; parallel at 2.8 A halves torque and the load stalls, blamed wrongly on the motor. Six-lead bipolar half-winding use sets current at half the full-winding rating. Trust the nameplate wiring note; the maker numbers are authoritative.
Wrong phasing usually does not kill the drive but makes the motor jitter or jerk. The rule: same phase lowest resistance, different phase about double. On a four-lead motor, phase resistance is typically 1 to 2 ohms, so A-to-B reads about twice that. After wiring, hand-rotation shows clear detents; power up slowly and if the direction is wrong, swap one phase pair, never both. Match terminal markings to the colour table; colour codes differ between makers.
| Termination | Drive type | Current setting | Trait |
|---|---|---|---|
| Four leads | Bipolar drive | Nameplate rating | Best torque use |
| Six leads unipolar | Unipolar drive | Nameplate rating | Half winding, less torque |
| Six leads bipolar | Bipolar drive | 50 percent of rating | Tap floating |
| Eight leads series | Bipolar drive | 70 percent of rating | Low-speed torque |
| Eight leads parallel | Bipolar drive | 140 percent of rating | Better speed |
| Identification | Multimeter | Same phase lowest | Other phase double |
Label every wiring job: which leads are phase A and B, series or parallel, and the current DIP position, taped by the motor mount. Replacements then wire from the label without re-measuring.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Terminations follow GB/T 12350 for small motors and GB/T 4728 graphical symbols; drive safety follows GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.